Page 51
BCS Products Security Handbook 555-025-600 Issue 6 December 1997 Large Business Communications Systems Page 3-5 Keeping Unauthorized Third Parties from Entering the System 3 Figure 3-1. Remote Access Call Path INCOMING REMOTE ACCESS CALL YES YES NO YES CODE?VALID CODE ENTERED CODE?VALID STOP BARRIER CODE REQUIRED?NO APPLY SECURITY VIOLATION NOTIFICATION STOP NO STOP YES ROUTE TO ATTENDANT OR DISCONNECT STOPNO CODE ENTERED ACCESS DIAL TONE? LOG INVALID ATTEMPT DISCONNECT CALL SYSTEM DIAL TONECALL...
Page 52
BCS Products Security Handbook 555-025-600 Issue 6 December 1997 Large Business Communications Systems Page 3-6 Keeping Unauthorized Third Parties from Entering the System 3 For DEFINITY ECS, DEFINITY G1, G3, and System 75, you can assign up to 10 barrier codes to provide the first checkpoint. When barrier codes are required for Remote Access, callers hear a special dial tone, and then must enter a valid barrier code before they can access the PBX system. NOTE: With DEFINITY ECS, DEFINITY G1, G3,...
Page 53
BCS Products Security Handbook 555-025-600 Issue 6 December 1997 Large Business Communications Systems Page 3-7 Keeping Unauthorized Third Parties from Entering the System 3 code should be used to screen entry into Remote Access; authorization codes can then be used to screen outgoing calls on Automatic Alternate Routing (AAR), Automatic Route Selection (ARS), and World Class Routing (WCR) (G2.2) trunks. Authorization Codes1 NOTE: For all systems, once established, the number of digits (four to...
Page 54
BCS Products Security Handbook 555-025-600 Issue 6 December 1997 Large Business Communications Systems Page 3-8 Keeping Unauthorized Third Parties from Entering the System 3 System 85, DEFINITY G2, and G3 users. However, it is best to keep the number of authorized users to a minimum. To maximize the security of the system, follow these steps: nWhen assigning authorization codes, give the users the lowest possible FRL needed for their calling requirements. nBe sure to remove any unused...
Page 55
BCS Products Security Handbook 555-025-600 Issue 6 December 1997 Large Business Communications Systems Page 3-9 Keeping Unauthorized Third Parties from Entering the System 3 For DEFINITY ECS, DEFINITY G1, G3, and System 75, trunks translated for Remote Access can be given a night service destination. Although it is not recommended, trunks accessing the system can be assigned a Remote Access extension as a night service destination. The system will change to either allow or deny access for a...
Page 56
BCS Products Security Handbook 555-025-600 Issue 6 December 1997 Large Business Communications Systems Page 3-10 Keeping Unauthorized Third Parties from Entering the System 3 dialed (or inferred), routes calls to the vector. Calls processed by the vector carry the permissions and restrictions associated with the COR of the VDN . In order to deny incoming callers access to outgoing facilities, including tie lines, configure the COR of the VDN to prohibit outgoing access. To do this, follow the...
Page 57
BCS Products Security Handbook 555-025-600 Issue 6 December 1997 Large Business Communications Systems Page 3-11 Tools that Restrict Unauthorized Outgoing Calls 3 Use of the acknowledgment option is strongly recommended for those systems utilizing both Remote Access and Facility Test Call (for notification if the feature is inadvertently left enabled), or those systems requiring notification if Facility Test Call is linked to hacking activity. Tools that Restrict Unauthorized Outgoing Calls Use...
Page 58
BCS Products Security Handbook 555-025-600 Issue 6 December 1997 Large Business Communications Systems Page 3-12 Tools that Restrict Unauthorized Outgoing Calls 3 Class of Restriction For DEFINITY ECS, DEFINITY G1, G3, and System 75, the Class of Restriction (COR) places calling permissions and restrictions on both the calling party and the called extension. Up to 64 CORs can be defined in the system. For DEFINITY ECS, DEFINITY G3rV1, G3i-Global, and G3V2, the number of CORs has been increased...
Page 59
BCS Products Security Handbook 555-025-600 Issue 6 December 1997 Large Business Communications Systems Page 3-13 Tools that Restrict Unauthorized Outgoing Calls 3 The following restrictions can be placed on the originating station or trunk: nOutward Restricted: cannot make Public Network Calls via AAR/ARS or TACs. Calls can be placed to internal stations, to tie trunks via TACs, and off-switch via the Uniform Dial Plan (UDP). NOTE: Some states require that all telephones be able to dial emergency...
Page 60
BCS Products Security Handbook 555-025-600 Issue 6 December 1997 Large Business Communications Systems Page 3-14 Tools that Restrict Unauthorized Outgoing Calls 3 accessed. After the vector is accessed, the COR of the VDN is used for further call permission checking. See also ‘‘ Restriction Override (3-way COR Check)’’ on page 3-14. Restriction Override (3-way COR Check) The Restriction Override feature, which is available only with DEFINITY G3i-Global and G3V2 and later, determines whether or...