    							ENGLISH-10ENGLISH-10
    O O O O
    P P P P
    E E E E
    R R R R
    A A A A
    T T T T
    I I I I
    O O O O
    N N N N
    S S S S
           
    ( ( ( (
    c c c c
    o o o o
    n n n n
    t t t t
    i i i i
    n n n n
    u u u u
    e e e e
    d d d d
    ) ) ) )
    Basic Operation
    The basic operations shown in Table 3 is performed from the supplied remote control transmitter or
    the projector control panel. Items indicated by (*) may be used from the control panel.
    Table 3 . Basic Operation
    ItemDescription
    INPUT
    SELECT
    Select Input Signal (*):Press the INPUT button.RGB IN 1→RGB IN 2→DVI→VIDEO IN →S-VIDEO IN →COMPONENT VIDEO (→RGB IN 1)Select RGB Input : Press the RGB button.VIDEO IN / S-VIDEO IN / COMPONENT VIDEO →RGB IN 1 / RGB IN 2 / DVI
    RGB IN 1 →RGB IN 2 → DVI (→RGB IN 1)
    Select Video Input :Press the VIDEO button.RGB IN 1 / RGB IN 2 / DVI →VIDEO IN / S-VIDEO IN / COMPONENT VIDEO
    VIDEO IN →S-VIDEO IN →COMPONENT VIDEO (→VIDEO IN)
    • The selected signal name is displayed for approximately 3 seconds when the input
    signal is changed.
    POSITION
    Set/Clear Position Adjustment Mode :Press the POSITION button.The [ ] icon is displayed in the POSITION mode.
    Image Position Adjustment:Press the  , , and  buttons in the
    POSITION mode.
    • Valid only in the MAGNIFY mode with a video signal is input.
    • After approximately 10 seconds of inactivity the [ ] icon is extinguished and the
    POSITION mode is cleared automatically.
    • , , and 
    buttons may operate as the mouse control button. Refer to page 4.
    RESET (*)
    Initialise Each Item :Select an item and press the RESET button.
    Initialise Position Adjustment :Press the RESET button and the
    POSITION mode. This function is valid only when RGB signal is input.
    • Valid except for the VOLUME, LANGUAGE and H PHASE.
    • The RESET button may operate as the mouse control button. Refer to page 4.
    MAGNIFY
    Set MAGNIFY Mode : Press the MAGNIFY  button.
    Move Magnified Area :Run the POSITION in the MAGNIFY mode.
    Adjust Magnification :Press the MAGNIFY  /  button in MAGNIFY
    mode.
    Clear MAGNIFY Mode :Press the MAGNIFY  button.
    • The MAGNIFY mode is cleared by running or setting the AUTO, ASPECT, INPUT
    SELECT or VIDEO, or by changing the input signal.
    OFF
    FREEZE
    Set/Clear FREEZE Mode :Press the FREEZE button. The [II] icon is
    displayed, and the image frozen, in the FREEZE mode.
    • The FREEZE mode is cleared by running or setting POSITION, VOLUME, MUTE,
    Automatic Adjustment, BLANK ON/OFF, or MENU ON/OFF, or by changing the
    input signal.
    • Do not forget to clear frozen static images.
    •  Strong light and obstacles will interfere with operation of the remote control transmitter.NOTE
    EW    1.  
    						
    							ItemDescription
    VOLUMEVolume Adjustment :Press the VOLUME / button.
    MUTESet/Clear Mute Mode :Press the MUTE button. No sound is heard in the
    MUTE mode.
    AUTO
    Automatic Adjustment at RGB Input :Press the AUTO button. Horizontal
    position(H.POSIT), vertical position (V.POSIT),clock phase (H.PHASE),
    and horizontal size(H.SIZE) are automatically adjusted. Use with the
    window at maximum size in the application display.
    Automatic Adjustment at Video Input :Press the AUTO button. A signal
    type appropriate for the input signal is selected automatically. Valid only
    when AUTO is set for VIDEO on the menu.
    • This operation requires approximately 10 seconds. It may not function correctly
    with some input signals.
    BLANK
    ON/OFFSet/Clear Blank Mode:Press the BLANK button. No image is displayed in
    the Blank mode. The screen color is as set in BLANK on the Image menu.
    MENU
    ON/OFF (
    *)
    Menu Display Start/Stop:Press the MENU button.• The menu display is terminated automatically after approximately 10 seconds of
    inactivity.
    MENU
    SELECT
    Select Menu Type:Press the MENU SELECT button. Allows the user to
    select the normal menu or the single menu. Only the selected item is
    displayed on the single menu, and other items are displayed with the 
    and  buttons as with the normal menu.
    • Valid only when the Setup menu is used. Push the MENU SELECT button after
    selecting items such as BRIGHTNESS.
    • The MENU SELECT button may operate as the mouse control button. Refer to
    page 4.
    Normal menu Single menu
    P.IN P.
    MODESelect Mode of P.IN P. Display :Press the PinP button.
    Small
    →Large→P.IN P.off (→Small)
    • Valid only at RGB IN 1, RGB IN 2 or DVI input.
    KEYSTONE
    Set / Clear KEYSTONE Mode(*):Press the KEYSTONE  button.
    Select KEYSTONE Mode :Press the  /  button in the KEYSTONE
    mode.  Vertical 
    ↔Horizontal
    Adjust KEYSTONE :Press the / button.
    • The image may not be appeared properly when this function is activated on same
    input signals.
    • The adjustable range of distortion correction will be different among input signals.
    ENGLISH-11
    ENGLISH
    ENGLISH-11
    O O O O
    P P P P
    E E E E
    R R R R
    A A A A
    T T T T
    I I I I
    O O O O
    N N N N
    S S S S
           
    ( ( ( (
    c c c c
    o o o o
    n n n n
    t t t t
    i i i i
    n n n n
    u u u u
    e e e e
    d d d d
    ) ) ) )
    Items indicated by (*) may be used from the control panel.
    Table 3. Basic Operation (continued)
    CONTRAST-2
    BRIGHT
    CONTRAST
    V POSIT
    H POSIT
    H PHASE
    H SIZE
    COLOR BAL R
    COLOR BAL B
    ASPECT0
    -2
    +1 
    0
    0 100
    100
    800SETUP INPUT OPT.IMAGE(MENU SELECT)
    EW    1.  
    						
    							ENGLISH-12ENGLISH-12
    O O O O
    P P P P
    E E E E
    R R R R
    A A A A
    T T T T
    I I I I
    O O O O
    N N N N
    S S S S
           
    ( ( ( (
    c c c c
    o o o o
    n n n n
    t t t t
    i i i i
    n n n n
    u u u u
    e e e e
    d d d d
    ) ) ) )
    Setup MenuThe following adjustments and settings are possible
    when SETUP is selected at the top of the menu. Part
    of the Setup menu differs between RGB input and
    video input. Select an item with the  and
    buttons, and start operation. Use the Single menu to
    reduce menu size (see Table 3, MENU SELECT).
    Table 4. Setup Menu
    VIDEO
    S-VIDEO
    COMPONENT VIDEO RGB IN 1
    RGB IN 2
    DVI
    BRIGHT
    CONTRAST
    V POSIT
    H POSIT
    H PHASE
    H SIZE
    COLOR BAL R
    COLOR BAL B
    ASPECT0
    -2
    +1 
    0
    0 100
    100
    800SETUP INPUT OPT.IMAGEBRIGHT
    CONTRAST
    SHARPNESS
    COLOR
    TINT
    H PHASE
    COLOR BAL  R
    COLOR BAL  B
    ASPECT0
    +1
    +1
    0
    0
    0
    0
    0SETUP INPUT OPT.IMAGE
    ItemDescriptionRGB IN 1
    RGB IN 2DVIVIDEOS-VIDEOCOMPONENT
    BRIGHTAdjustment: Dark ↔Light ✔✔✔
    CONTRASTAdjustment:Weak ↔Strong ✔✔✔
    V POSITAdjustment:Down ↔Up ✔--
    H POSITAdjustment:Left ↔Right ✔--
    H PHASEAdjustment:Left ↔Right 
    • Adjust to eliminate flicker.✔-✔
    H SIZE
    Adjustment:Small ↔Large • The image may not be displayed correctly if the horizontal
    size is excessive. In such cases, press the RESET button,
    and initialize the horizontal size.✔--
    SHARPNESSAdjustment:Soft ↔Clear --✔
    COLORAdjustment:Light ↔Dark --✔
    TINTAdjustment:Red ↔Green • Valid only when NTSC or NTSC 4.43 signal is received.--✔
    COLOR BAL RAdjustment:Light ↔Dark ✔✔✔
    COLOR BAL BAdjustment:Light ↔Dark ✔✔✔
    ASPECT
    Select Image Aspect Ratio :
    Full [ ] 
    ↔16:9[ ]  
    Select Position of Image:
    Press the  button while 16:9[ ] is selected.
    Center
    →Down →Up (→Center )
    ✔✔-
    Select Image Aspect Ratio:
    4:3[ ] 
    ↔16:9[ ] ↔4:3 small[ ]
    Select Position of Image :
    Press the  button while 16:9[ ] / 4:3 small[ ]
    is selected.
    Center
    →Down→Up (→Center )• 4:3 small cannot be selected with the input of 720p or
    1080i component.
    • 4:3 small may not be displayed correctly with some input
    signals.
    --✔
    EW    1.  
    						
    							ENGLISH-13
    ENGLISH
    ENGLISH-13
    O O O O
    P P P P
    E E E E
    R R R R
    A A A A
    T T T T
    I I I I
    O O O O
    N N N N
    S S S S
           
    ( ( ( (
    c c c c
    o o o o
    n n n n
    t t t t
    i i i i
    n n n n
    u u u u
    e e e e
    d d d d
    ) ) ) )
    Input MenuThe following functions are available when INPUT is selected on the
    menu. Select an item with the and buttons, and start or stop
    operation with the and buttons. The function indicated (**) are
    effective on video input mode only, not on RGB input mode, except in
    the P.IN P. window on RGB input mode.
    Table 5. Input Menu
    EXECUTE
    CANCELAUTO
    RGB
    VIDEO
    HDTV SETUP INPUT OPT.IMAGE
    ItemDescription
    AUTO
    Automatic Adjustment at RGB Input: Select the EXECUTE with the
    button.Horizontal position (H.POSIT), vertical position (V.POSIT), clock
    phase (H.PHASE), and horizontal size (H.SIZE) are automatically adjusted.
    Use with the window at maximum size in the application display.
    Automatic Adjustment at Video Input: Select the 
    EXECUTEwith the 
    button. A signal type appropriate for the input signal is selected
    automatically when 
    EXECUTEis selected automatically. Valid only when
    AUTO is set for VIDEO on the menu.
    • This operation requires approximately 10 seconds. It may not function correctly with
    some input signals. Pressing the AUTO button in this case may correct this problem.
    • This function is the same as for the AUTO function in Basic operation.
    RGB
    Displays RGB Input Frequency:Displays the horizontal and vertical sync
    signal frequencies for RGB input.
    • Valid only at RGB input.
    VIDEO (**)
    Select Video Signal Type:Select the signal type with the  and 
    buttons. Select NTSC, PAL, SECAM, NTSC4.43, M-PAL, or N-PAL as
    appropriate for the input signal. The selection of AUTO enables and
    executes the function AUTO (Automatic Adjustment at Video Input), except
    for the N-PAL input.
    • Use this function when the image becomes unstable (eg. the image becomes
    irregular, or lacks color) at VIDEO/S-VIDEO input.
    • Automatic Adjustment requires approximately 10 seconds. It may not function
    correctly with some input signals. Pressing the AUTO button in this case may correct
    this problem except for the N-PAL input.
    • For the COMPONENT VIDEO input, this function is not effective and the signal
    type is distinguished automatically. Refer to the item HDTV of the OPT. Menu for the
    signal of HDTV.
    HDTVSelect HDTV mode:Select the 1035i mode or 1080i mode suitable for the
    input signal with the  /  button.
    EW    1.  
    						
    							ENGLISH-14ENGLISH-14
    O O O O
    P P P P
    E E E E
    R R R R
    A A A A
    T T T T
    I I I I
    O O O O
    N N N N
    S S S S
           
    ( ( ( (
    c c c c
    o o o o
    n n n n
    t t t t
    i i i i
    n n n n
    u u u u
    e e e e
    d d d d
    ) ) ) )
    Image Menu
    The following adjustments and settings are available when IMAGE is
    selected on the menu. Select an item with the and buttons, and 
    start or stop operation with the and buttons.
    Table 6. Image Menu
    BLANK
    START UP
    Desk Top
    MIRROR
    P. IN P. POSIT
    P. IN P. INPUT
    GAMMA
    Desk TopORIGINAL
    SETUP INPUT OPT.IMAGE
    ItemDescription
    BLANK
    Select Blank Screen: Select the screen in case of the BLANK mode with the  /
    button. The selected one (Desk Top, ORIGINAL or one colors) is displayed when the
    BLANK mode is ON.
    Desk Topis a mode that the customer-customized screen is displayed. This is the
    blue screen at the factory setting. Refer to the description of Desk Top below.
    ORIGINALis a mode that the factory fixed screen is displayed.
    • When Desk Top or ORIGINAL is selected, the screen is going to the black after several minutes.
    START UP
    Select Start Up Screen:Select the screen in case of no signal input with the  /
    button. The selected one (Desk Top, ORIGINAL or TURN OFF) is displayed when no
    signal is input.
    Desk Topis a mode that the customer-customized screen is displayed. This is the
    blue screen at the factory setting. Refer to the description of Desk Top below.
    ORIGINALis a mode that the factory fixed screen is displayed.
    TURN OFFdisplays the blue screen.
    • When Desk Top or ORIGINAL is selected, the screen is going to the black after several minutes.
    Desk Top
    Set Desk Top Mode:Select the EXECUTE with the  button to display the Desk
    Top menu and set the Desk Top mode for BLANK and START UP functions.
    ESCclears and closes the menu box.
    NORM.is default of the Desk Top menu.
    FREEZEfreezes the image and displays the frame to capture.
    Press the  button after freeze to go to the Desk Top Capture Position mode.
    In the Desk Top Capture Position mode,
    the buttons  , , and  allow to
    move the frame to capture.
    After adjusting the position, press the KEYSTONE button to go to the Desk Top
    Display Size mode.
    To cancel freezing and return to the NORM. of the Desk Top menu, press the
    RESET button.
    In the Desk Top Display Size mode
    , select the magnification x1, x2 or FULL with the
    button  / . After selecting the magnification, press the KEYSTONE button to go
    to the CAPT. mode and start capturing.
    To return to the Desk Top Capture Position mode, press the RESET button.
    CAPT.executes a capturing the image. It requires about 20 seconds. After capturing,
    the captured image will be displayed for about 10 seconds.
    MIRRORSelect Mirror Status:Select mirror status with  /  button.
    P. IN P.
    POSITSelect Position of P. in P. Display :Press the or button.
    ↔↔↔
    • Valid only at RGB IN 1, RGB IN 2 or DVI input.
    P. IN P.
    INPUTSelect signal of P. in P. Display :Press the  or  button.
    VIDEO ↔S-VIDEO 
    GAMMASelect Gamma Mode:Select the gamma mode with the  /  button.
    NORMAL ↔CINEMA ↔DYNAMIC
    EW    1.  
    						
    							ENGLISH-15
    ENGLISH
    ENGLISH-15
    O O O O
    P P P P
    E E E E
    R R R R
    A A A A
    T T T T
    I I I I
    O O O O
    N N N N
    S S S S
           
    ( ( ( (
    c c c c
    o o o o
    n n n n
    t t t t
    i i i i
    n n n n
    u u u u
    e e e e
    d d d d
    ) ) ) )
    Options Menu
    The following adjustments and settings are available when OPT. is
    selected on the menu. Select an item with the and buttons, and
    start or stop operation with the  and buttons. 
    Table 7. Options Menu
    VOLUMEMENU COLORLANGUAGE
    AUTO OFF
    SYNC ON G
    WHISPER
    IR REMOTE
    16 SETUP INPUT OPT.IMAGE
    ItemDescription
    VOLUMEReduce ↔Increase 
    MENU COLORSelect Menu Background Color:Select with the  /  button.
    LANGUAGESelect Menu Display Language:Select with the  /  button.
    AUTO OFF
    Set AUTO OFF:Set 1~99 minutes with the  /  button. The system
    automatically enters the standby mode when a signal is not received for
    the set time.
    Clear AUTO OFF:Select STOP (0 min.) with the  button. When
    STOP is selected the system does not enter the standby mode even if
    no signal is received.
    SYNC ON G
    SYNC ON G Valid:Select TURN ON with the  button.
    SYNC ON G Invalid:Select TURN OFF with the  button.
    • May not be displayed correctly with some input signals when SYNC ON G is
    valid. In such cases, remove the signal connector so that no signal is received,
    set SYNC ON G to invalid, and reconnect the signal.
    WHISPER
    Set / Crear WHISPER Mode: Press the  /  button.  When the
    WHISPER is selected, the WHISPER mode is active. In the WHISPER
    mode, acoustic noise level from the unit is reduced, and brightness level
    on screen is a little lower.
    IR REMOTE
    Select Remote Control Sensor: Select the sensors to activate along
    the menu with the  /  button. Use this function if the remote does
    not work stably. The ambient light may affect the remote.
    VOLUMEMENU COLORLANGUAGE
    AUTO OFF
    SYNC ON G
    WHISPER
    IR REMOTE SETUP INPUT OPT.
    IMAGE
    1 1
    2 2
    3
    3
    : active
    : inactive
    EW    1.  
    						
    							ENGLISH-16
    O O O O
    P P P P
    E E E E
    R R R R
    A A A A
    T T T T
    I I I I
    O O O O
    N N N N
    S S S S
           
    ( ( ( (
    c c c c
    o o o o
    n n n n
    t t t t
    i i i i
    n n n n
    u u u u
    e e e e
    d d d d
    ) ) ) )
    No Signal MenuThe same adjustments and settings are available as with the Image and
    Options menus when the MENU button is pressed during display of the
    “NO INPUT IS DETECTED ON ***” or “SYNC IS OUT OF RANGE
    ON ***” message while no signal is received.Select an item with the
    and buttons, and start or stop operation with the and buttons.
    Table 8. No Signal Menu
    VOLUME
    BLANK
    START UP
    MIRROR
    MENU COLORLANGUAGE
    AUTO OFF
    SYNC ON G
    WHISPER
    IR REMOTE
    16
    ItemDescription
    VOLUME
    Reduce ↔Increase • When this function is used, audio input is automatically switched to video. The audio input can
    be switched by moving the DISK PAD left and right during the display of the volume adjustment
    bar. The volume adjustment bar is displayed by pressing VOLUME  /  button.
    BLANK
    Select Blank Screen: Select the screen in case of the BLANK mode with the  /
    button. The selected one (Desk Top, ORIGINAL or one colors) is displayed when the
    BLANK mode is ON.
    Desk Topis a mode that the customer-customized screen is displayed. This is the
    blue screen at the factory setting. Refer to the description of Desk Top below.
    ORIGINALis a mode that the factory fixed screen is displayed.
    • When Desk Top or ORIGINAL is selected, the screen is going to the black after several minutes.
    START UP
    Select Start Up Screen:Select the screen in case of no signal input with the  / button.
    The selected one (Desk Top, ORIGINAL or TURN OFF) is displayed when no signal is input.
    Desk Topis a mode that the customer-customized screen is displayed. This is the
    blue screen at the factory setting. Refer to the description of Desk Top below.
    ORIGINALis a mode that the factory fixed screen is displayed.
    TURN OFFdisplays the blue screen.
    • When Desk Top or ORIGINAL is selected, the screen is going to the black after several minutes.
    MIRRORSelect Mirror Status:Select the mirror status with the  /  button.
    MENU COLORSelect Menu Background Color:Select the color with the  /  button.
    LANGUAGESelect Menu Display Language:Select the language with the  /  button.
    AUTO OFF
    Set AUTO OFF:Set 1~99 minutes with the  /  button. The system
    automatically enters the standby mode when a signal is not received for the set time.
    Clear AUTO OFF:Select the STOP (0 min.) with the  button. When the STOP is
    selected the system does not enter the standby mode even if no signal is received.
    SYNC ON G
    SYNC ON G Valid:Select the TURN ON with the  button.
    SYNC ON G Invalid:Select the TURN OFF with the  button.
    • May not be displayed correctly with some input signals when the SYNC ON G is valid. In such
    cases, remove the signal connector so that no signal is received, set the SYNC ON G to invalid,
    and reconnect the signal.
    WHISPERSet / Crear WHISPER Mode: Press the  /  button.  When the WHISPER is
    selected, the WHISPER mode is active. In the WHISPER mode, acoustic moise level
    from the unit is reduced, and brightness level on screen is a little lower.
    IR REMOTE
    Select Remote Control Sensor: Select the sensors to activate along the menu with
    the  /  button. Use this function if the remote does not work stably. The ambient
    light may affect the remote.
    VOLUME
    BLANK
    START UP
    MIRROR
    MENU COLORLANGUAGE
    AUTO OFF
    SYNC ON G
    WHISPER
    IR REMOTE1 1
    2 2
    3
    3
    : active
    : inactive
    EW    1.  
    						
    							ENGLISH-17
    ENGLISH
    MAINTENANCE MAINTENANCE
    Lamp
    HIGH VOLTAGE
    HIGH TEMPERATURE
    HIGH PRESSURE
    Contact your dealer before replacing the lamp.
    For the optional lamp, see the item “Optional Parts” of the Table 12.
    Before replacing the lamp, switch power OFF, remove the power cord from the power outlet, and
    wait approximately 45 minutes until the lamp has cooled. The lamp may explode if handled at high
    temperatures.
    Lamp Life
    Projector lamps have a finite life. The image will become darker, and hues will become weaker,
    after a lamp has been used for a long period of time. 
    Replace the lamp if the LAMP indicator is red, or the CHANGE THE LAMP message appears
    when the projector is switched ON. See Table 9 of P.20 and Table 10 of P.21.
    •The LAMP indicator is also red when the lamp unit reaches high temperature. Before
    replacing the lamp, switch power OFF, wait approximately 20 minutes, and switch power ON again.
    If the LAMP indicator is still red, replace the lamp.NOTE
    WARNINGAmercury lamp used in this LCD projector is made of glass and has high
    internal pressure.  The mercury lamp can burst with a big noise due to deterioration
    resulting from a shock, crack and passage of time, and can end its service life in unlit
    condition.  Lamps also have a considerably different service life and can sometimes end up
    in burst or turn to unlit condition soon after use.  Furthermore, when the lamp is blown up,
    glass fragments can get scattered around the lamp house and some gas containing mercury
    inside the lamp can leak out of the projector’s air vent.
    • Handle the lamp with utmost care as it can burst during use if subjected to a shock or
    impact or if scratched or cracked.
    • Probability for the burst will increase if the lamp is used for extended period of time or
    used exceeding the period of replacement.  You are advised to follow instructions for lamp
    replacement as soon as they are given (Refer to Table 9 of Page 20, Table 10 of Page 21).
    Avoid any reuse of an old lamp (used lamp) since such reuse can result in burst.
    • In case the lamp gets blown up in a short period of time after use, some electrical failures
    or troubles other than the lamp itself may be suspected as causes.  Under such
    circumstances, consult the store where you purchased it or a service company.
    • Should the lamp burst (accompanied by a big bursting noise), perform ventilation
    sufficiently, and exercise maximum caution not to inhale any gas out of the projector’s air
    vent or not to let it enter your eyes or mouth.
    • Should the lamp burst (accompanied by a big bursting noise), make absolutely sure to
    unplug the power cord from the outlet and ask the store where you bought the lamp for
    immediate replacement.  You should not engage in cleanup or replacement of the lamp by
    yourself since scattered glass fragments can damage the inside of projector or can result in
    personal injury when you handle it. 
    • When you dispose of any used lamps, be sure to observe and follow local ordinances and
    regulations of the area or district where they are subjected to disposal.  Generally speaking,
    the lamps are treated similarly as glasses and bottles in most cases, but there are areas or
    districts where lamps are classified as a separate collection, and so be sure to use caution. 
    • Never use the lamp in a state where the lamp cover is removed.
    EW    1.  
    						
    							ENGLISH-18ENGLISH-18
    M M M M
    A A A A
    I I I I
    N N N N
    T T T T
    E E E E
    N N N N
    A A A A
    N N N N
    C C C C
    E E E E
           
    ( ( ( (
    c c c c
    o o o o
    n n n n
    t t t t
    i i i i
    n n n n
    u u u u
    e e e e
    d d d d
    ) ) ) )
    Replacing the Lamp
    1. Switch the projector OFF, remove the power cord from the
    power outlet, and wait at least 45 minutes for the unit to cool.
    2. Prepare a new lamp.
    3. Check that the projector has cooled sufficiently, and gently
    turn it upside down.
    4. Loosen the two screws as shown in the diagram, and remove
    the lamp cover.
    5. Loosen the three screws, and gently remove the lamp while
    holding the grips. Touching the inside of the lamp case may
    result in uneven coloring.
    6. Install the new lamp and tighten the three screws firmly.
    Also steadily push the opposite side of the screwed lamp into
    the unit.
    7. Replace the lamp cover in position and tighten the  two
    screws firmly.
    8. Gently turn the projector right-side up.
    Resetting the Lamp Timer
    Reset the lamp timer after replacing the lamp. When the lamp has been replaced after the LAMP
    indicator is red, or the CHANGE THE LAMP message is displayed, complete the following
    operation within ten minutes of switching power ON. The power will be turned off automatically in
    over 10 minutes.
    1. Switch power ON, and press the RESET button, for approximately three seconds. The ‘LAMP
    xxxx hr’ message will appear on the lamp timer on the bottom of the screen.
    2. Press the MENU button on the remote control transmitter, or the RESET button on the control
    panel, while the lamp timer is displayed. The ‘LAMP xxxx 
    →0 CANCEL’ message will
    then appear.
    3. Press the  and select 0, and wait until the timer display is cleared.
    •Do not reset the lamp timer without replacing the lamp. Reset the lamp timer always
    when replacing the lamp. The message functions will not operate  properly if the lamp timer is not
    reset correctly.NOTE
    CAUTION• Ensure that screws are tightened
    properly. Screws not tightened fully may result
    in injury or accidents.
    • Do not use the projector with the lamp cover
    removed.
    EW    1.  
    						
    							ENGLISH-19
    ENGLISH
    ENGLISH-19
    M M M M
    A A A A
    I I I I
    N N N N
    T T T T
    E E E E
    N N N N
    A A A A
    N N N N
    C C C C
    E E E E
           
    ( ( ( (
    c c c c
    o o o o
    n n n n
    t t t t
    i i i i
    n n n n
    u u u u
    e e e e
    d d d d
    ) ) ) )
    Air Filter
    Cleaning the air Filter
    The air filter should be cleaned as described below at intervals of approximately 100 hours.
    1. Switch the projector power supply OFF, and remove the power cord from the power outlet.
    2. Clean the air filter with a vacuum cleaner.
    Other Maintenance
    Maintenance Inside the Equipment
    For safety reasons, ensure that the equipment is cleaned and checked by the dealer once every two
    years. Maintaining the equipment by yourself is dangerous.
    Cleaning the Lens
    Gently wipe the lens with lens cleaning paper. Do not touch the lens with your hands.
    Cleaning the Cabinet and Remote control transmitter
    Gently wipe with a soft cloth. If dirt and stains etc. are not easily removed, use a soft cloth
    dampened with water, or water and a neutral detergent, and wipe dry with a soft, dry cloth.
    CAUTION• Switch power OFF and remove the power cord from the power
    outlet before beginning maintenance work. Please read the separate “Safety
    Guide” thoroughly to ensure that maintenance is performed correctly.
    • Do not use detergents or chemicals other than those noted above (e.g. benzene
    or thinners).
    • Do not use cleaning sprays.
    • Do not rub with hard materials, or tap the equipment.
    CAUTION• Switch power OFF and remove the power cord from the power
    outlet before beginning maintenance work. Please read the separate “Safety
    Guide” thoroughly to ensure that maintenance is performed correctly.
    • Replace the air filter if contamination cannot be removed, or if it is damaged.
    Contact your dealer in such case. For the optional air filter, see the item “Option
    Parts” of the Table 12. 
    • Do not use the equipment with the air filter removed.
    • When the air filter is clogged with dust etc. the power supply is switched OFF
    automatically to prevent the temperature rising inside the projector.
    Replacing the Air Filter
    Replace the air filter if contamination cannot be removed, or if it is damaged.
    1. Remove the filter cover.
    2. Remove the old filter.
    3. Set the new filter and the filter cover.
    •When this projector is brought into a warm room from a cold outdoor, condensation can
    take place on the projection lens and mirror inside, blurring the screen and reducing your eyesight,
    but do not worry.  The condensation will disappear and the screen will return to a normal condition
    no sooner than the projector acclimates to the surrounding temperature.NOTE