Page 21
21 \b \b \b \b Is the supplied voltage 120 V AC? Is the voltage between the 2 FILTER ASSEMBLY connectors 120 V AC? Is the LED (1) on? Are the connectors (2) on the PWB loose? Is wire of the DISPLAY PWB ASSEMBLY broken? Replace DISPLAY PWB ASSEMBLY or repair wire. Check the fuse or reset the circuit breaker. Replace the FILTER ASSEMBLY (CIRC)....
Page 22
22 \b \b \f Tighten Tighten Have all the transit bolts and base packing been removed? Remove the transit bolts and Base packing. Move the washer or reinforce the floor. Is the washer installed on a solidly constructed floor? Check if the washer is perfectly level as follows: Check the leveling of the washer with a Level and check that the washer is stable. Put an unbalance part (rubber) inside of drum and start QC test mode and run in high spin (Refer to section...
Page 23
23 NO YES NO NO YES NO YES YES NO NO YES YES YES NO NO NO YES SOFTENER MAX 5 4 Bleach Bleach Steam Steam Is water supply shut-off? Is the tap opened? When you press both WASH/RINSEbutton and DELAY WASH button simultaneously, is the water level frequency below 246? Is the inlet valve filter clogged? Is resistance between each terminal of INLET VALVE ASSEMBLY 0.8-1.2 k Ω? Verify the voltage of the inlet valve connector is 120 V AC. (Refer to 7-2 QC TEST MODE) Is water supplied? Are receptacles...
Page 24
24 \b \f \f \b SOFTENER MAX SOFTENERMAX \b \b \b ABNORMAL SOUND LIQUID DETERGENT/SOFTENER/BLEACH DOES NOT FLOW IN Secure the bolt. Replace the STATOR ASSEMBLY or ROTOR ASSEMBLY. Refer to NO WATER SUPPLY Check the wiring on the dispenser. Put it in the correct compartment. Clean the Cap and Container. Is the motor bolt loosened? Is there friction noise coming from the motor? Is water supplied? Are the plugs correctly connected to the terminals of the INLET...
Page 25
25 \b \b \b \b Replace the SENSOR SWITCH ASSEMBLY. Replace the MAIN PWB ASSEMBLY. Repair the DRAIN HOSE ASSEMBLY. Remove foreign material. Reconnect or repair the connector Replace the DRAIN PUMP ASSEMBLY. Replace the MAIN PWB ASSEMBLY. Whenpressing WASH/RINSE and DELAY WASH at the same time after draining, is the water level frequency 255? When...
Page 26
26 (1) Extra Hot: 70 °C EXTRA RINSE at the same time,DELAY WASH and SB SB BL YL BL BL YL WHWH WH WH WH SB RD RD BL RD YL BK BK WH SB SB SB BL YL BL BL YL WHWH WH WH WH SB RD RD BLRD YL BK BK WH SB Push the THERMISTOR tightly to the rubber. Replace the Heater Assembly When checking the THERMISTOR on the tub, is the THERMISTOR loose? Water Temperature [°C] HEATING CONTINUOUSLY ABOVE THE SETTING WATER TEMPERATURE WASH HEATER TROUBLE
Page 27
27 \b \f \f \f \b WILL NOT CIRCULATE WATER Is the impeller of the drain pump clogged? Are the Hose Connector and/or Hose clogged? Is the connector disconnected, disassembled? Is the coil of the right side of drain pump open or short circuited? (Coil R is 18-30 Ω) When checking voltage between the connectors during spin, is the voltage 120 V AC, as...
Page 28
28 (1)(2) SB SB BL YL BL BL YL WHWH WH WH WH SB RD RD BLRD YL BK BK WH SB SB SB BL YL BL BL YL WHWH WH WH WH SB RD RD BLRD YL BK BK WH SB SPIN TROUBLE Check the SENSOR SWITCH ASSEMBLY or HOSE (Pressure). If the problem is on the SENSOR SWITCH ASSEMBLY or the HOSE, replace the SENSOR SWITCH ASSEMBLY or the HOSE. Normal Correct the connection. Replace the STATOR ASSEMBLY Check during spin if the frequency of the water level is 248 or more. Press the START/PAUSE button 2 times in QC Test mode, is...
Page 29
29 9. DISASSEMBLY INSTRUCTIONS DISPLAY PWB ASSEMBLY TOP PLATE ASSEMBLY CONTROL PANEL ASSEMBLY DRAWER CONTROL PANEL ASSEMBLY CONTROLPANELASSEMBLY Be sure to unplug the machine out of the outlet before disassembling and\ repairing the parts. Unscrew 2 screws on the back of the top plate. Pull the top plate backward and upward as shown. Disconnect the Display PWB Assembly connector from Trans cable. Pull out the drawer and unscrew 2 screws. Taking out 1 screw. Lift the side the Control Panel Assembly...
Page 30
30 Disconnect the POWER connector and SENSORSWITCH ASSEMBLY. Remove the Protect Cover. Disconnect the connectors. Unscrew 1 screw on the back. Disassemble the Main PWB. PROTECT COVER MAINPWBASSEMBLY