6Lift the blue levers on the imaging kit, and then pull it toward you. 7Press down on the blue levers, grasp the green handles on the sides, and then pull the imaging kit out. Warning—Potential Damage: Do not touch the underside of the imaging kit. This could damage the imaging kit. 8Remove the yellow, cyan, and magenta developer units. 9Unpack the replacement black imaging kit. Leave the packaging on the black developer unit. 10Gently shake the black developer unit side to side. Maintaining the printer 11
Page 12
11Remove the red shipping cover from the black developer unit. 12Insert the black developer unit. 13Replace the yellow, cyan, and magenta developer units. Note: Make sure each developer unit is inserted into a matching color slot. 14Place the used black imaging kit in the enclosed package. Maintaining the printer 12
Page 13
15Align and insert the imaging kit. 16Rotate the blue levers down until the imaging kit drops into place. 17Replace the waste toner bottle. Maintaining the printer 13
Page 14
18Replace the right side cover. 19Replace the toner cartridges. 20Close the top door. Maintaining the printer 14
Page 15
21Close the front door.Replacing a black and color imaging kit Replace the black and color imaging kit when Replace Color Imaging Kit appears. 1Grasp the front door at the side handholds, and then pull it toward you to open it. CAUTION—HOT SURFACE: The inside of the printer might be hot. To reduce the risk of injury from a hot component, allow the surface to cool before touching.Maintaining the printer 15
Page 16
2Open the top door. 3Remove the toner cartridges by lifting the handles, and then gently pulling away from the imaging kit. 4Remove the right side cover. Maintaining the printer 16
Page 17
5Press the green levers on each side of the waste toner bottle, and remove it. 6Lift the blue levers on the imaging kit, and then pull it toward you. 7Press down on the blue levers, grasp the green handles on the sides, and then pull the imaging kit out. Warning—Potential Damage: Do not touch the underside of the imaging kit. This could damage the imaging kit. 8Unpack the replacement black and color imaging kit. Leave the packaging on the developer units. 9Gently shake the yellow, cyan, magenta, and...
Page 18
10Remove the red shipping cover from the yellow, cyan, magenta, and black developer units. 11Insert the yellow, cyan, magenta, and black developer units. 12Place the used black and color imaging kit in the enclosed package. 13Align and insert the imaging kit. Maintaining the printer 18
Page 19
14Replace the waste toner bottle. 15Replace the right side cover. Maintaining the printer 19
Page 20
16Replace the toner cartridges. 17Close the top door. 18Close the front door. Maintaining the printer 20