Page 231
Repair information4-9 5026 Go Back Previous Next 4.Loosen the printhead mounting screws in the following order: D1, D2, and D3. 5.Remove the printhead alignment screw cover (E). 6.Reinstall the transfer module with the photoconductor units still attached. 7.Reconnect the transfer module cable. 8.Replace the toner cartridges. 9.Close the top access door. 10.Close the front access door. 11.Plug the electrical cord into the printer. 12.Plug the electrical cord into the outlet.
Page 232
4-10Service Manual 5026 Go Back Previous Next 13.Align the printhead skew for black. a.Enter the Diagnostic menu (turn off the printer, press and hold and , turn on the printer, and release the buttons when the clock graphic displays). b.Select REGISTRATION from the DIAGNOSTICS menu, and press Select (). c.Select Skew, and press Select (). d.Use or to set the Skew to zero, and press Select (). e.Press Back (). f.Scroll down to Quick Test, and press Select . A page similar to this one prints:
Page 233
Repair information4-11 5026 Go Back Previous Next g.Adjust the printhead alignment screw (G) to change the skew and straighten the image on the printout. If the top right alignment marks are lower than the top left alignment marks, rotate the alignment screw counterclockwise a full revolution, and print the Quick Test page. Repeat adjusting the screw and printing the Quick Test until the top alignment marks are the same distance from the top of the media. Note: One rotation of the printhead...
Page 234
4-12Service Manual 5026 Go Back Previous Next 14.Tighten the printhead mounting screws. a.Turn off the printer. b.Disconnect the power cord from the electrical outlet. c.Disconnect the transfer module cable. d.Press the two tabs on either side of the transfer module, and lift out the transfer module with the photoconductor units in place. e.Remove all of the toner cartridges. f.Tighten the printhead mounting screws in the following order: H1, H2, and H3. 15.Replace the printhead alignment screw...
Page 235
Repair information4-13 5026 Go Back Previous Next Registration (black) Top Margin 1.Reconnect the power cord to the electrical outlet, but do not turn on the printer yet. 2.Enter Diagnostic mode (press and hold and , turn on the printer, and release the buttons when the clock graphic displays). 3.Select REGISTRATION, and press Select . 4.Select Quick Test, and press Select or use the last Quick Test you used to adjust skew. 5.Select Top Margin, and press Select . 6.Adjust the values until both...
Page 236
4-14Service Manual 5026 Go Back Previous Next Left Margin 1.Adjust the left margin until the points of the left alignment marks touch the edge of the page. •Increasing the value ( ) moves the left alignment marks away from the edge of the page. •Decreasing the value ( ) moves the left alignment marks toward on the edge of the page. 2.Press Select ( ) to save the value. 3.Print the Quick Test page, and check the left alignment marks each time until you are satisfied. Right Margin 1.Adjust the right...
Page 237
Repair information4-15 5026 Go Back Previous Next 7.Select Quick Test in the Cyan menu, and press Select (). Two pages print. You may have to print these pages several times until you get T (Top Margin) and Z (Skew) aligned. Do not go to step 2 until T and Z are aligned. The first page is similar to the following:
Page 238
4-16Service Manual 5026 Go Back Previous Next 8.Determine the line under Fine Adjustment that is closest. If the value is beyond the Fine Adjustment scale, use either of the Coarse Adjustment scales. 9.Enter the number determined from the Fine Adjustment scale or the Coarse Adjustment scales on the part of the page for the “T” value. The current value is automatically entered on the sheet. At this point, it should be zero. 10.Enter the “New Cyan T value” on the operator panel using the left and...
Page 239
Repair information4-17 5026 Go Back Previous Next 12.Repeat this process for skew (Z). Dont forget to subtract the T value and add the current cyan Z value to obtain the new skew (Z) value. An example is shown below: 13.Continue to follow the directions on the bottom of the first page to find the Cyan Top Margin (T), the Skew (Z), and on the second page of the Quick Test page, the Left Margin (L), Right Margin (R), and Bow (P). 14.Repeat steps 2 through 11 for yellow and magenta. Note: Start each...
Page 240
4-18Service Manual 5026 Go Back Previous Next Printer removal procedures Precautions to take before maintenance work Do not implement any operation, removal, or modification and so on, which is not presented in this manual. 1.Turn the printer power off and unplug the power cable from the outlet prior to starting removals or checks. 2.Prior to starting any repairs, read and understand the warnings in this manual. •High temperature •High voltage •Laser radiation 3.Confirm the direction of all parts...