Land Rover Common Rail System Crs Denso Manual
Here you can view all the pages of manual Land Rover Common Rail System Crs Denso Manual. The Land Rover manuals for Automobile are available online for free. You can easily download all the documents as PDF.
Page 31
Operation Section1–26 Fuel Discharge Quantity Control • The diagram below shows that the suction starting timing (SCV (Suction Control Valve) ON) is constant (determined by the pump speed) due to the crankshaft position sensor signal. For this reason, the fuel suction quantity is controlled by changing the suction ending timing (SCV OFF). Hence, the suction quantity decreases when the SCV is turned OFF early and the quantity increases when the SCV is turned OFF late. • During the intake stroke, the...
Page 32
Operation Section1–27 3.3 HP3 Type (1) Construction and Characteristics • The supply pump is primarily composed of the pump unit (eccentric cam, ring cam, two plungers), the SCV (suction control valve), the fuel temperature sensor and the feed pump (trochoid type), and is actuated at 1/1 or 1/2 the engine rotation. • The two compact pump unit plungers are positioned symmetrically above and below on the outside of the ring cam. • The fuel discharge quantity is controlled by the SCV, the same as for the...
Page 33
Operation Section1–28 (2) Exploded View Q000836E Pump Housing CamshaftEccentric CamRing CamFeed Pump Plunger Element Sub-AssemblySCV (Suction Control Valve) Regulating ValveFuel Temperature Sensor Delivery Valve Delivery Valve Delivery Valve Element Sub-Assembly Plunger
Page 34
Operation Section1–29 (3) Component Part Functions Feed Pump • The trochoid type feed pump, which is integrated in the supply pump, draws fuel from the fuel tank and feeds it to the two plungers via the fuel filter and the SCV (Suction Control Valve). The drive shaft actuates the outer/inner rotors of the feed pump, thus causing the rotors to start rotating. In accordance with the space that increases and decreases with the movement of the outer and inner rotors, the feed pump draws fuel into the suction...
Page 35
Operation Section1–30 Suction Control Valve (SCV) • In contrast to the HP2, the SCV for the HP3 supply pump is equipped with a linear solenoid valve. The fuel flow vol- ume supplied to the high-pressure plunger is controlled by adjusting the engine ECU supplies power to the SCV (duty ratio control). When current flows to the SCV, the internal armature moves according to the duty ratio. The armature moves the needle valve, controlling the fuel flow volume according to the amount that the valve body fuel...
Page 36
Operation Section1–31 Duty Ratio Control - The engine ECU outputs sawtooth wave signals with a constant frequency. The value of the current is the effective (average) value of these signals. As the effective value increases, the valve opening decreases, and as the effec- tive value decreases, the valve opening increases. When the SCV Energized Duration (Duty ON Time) is Short - When the SCV energization time is short, the average current flowing through the solenoid is small. As a result, the needle...
Page 37
Operation Section1–32 When the SCV Energized Duration (Duty ON Time) is Long - When the energization time is long, the average current flowing to the solenoid is large. As a result, the needle valve is pressed out (in the compact SCV, the needle valve is pulled), creating a small valve opening. Subsequently, the fuel suction quantity decreases. Q002321E Compact SCV Needle ValveLarge OpeningFeed Pump Q002342E Needle Valve Small OpeningSCV Feed Pump Conventional SCV
Page 39
Operation Section1–34 Normally Closed Type - When the solenoid is energized, the needle valve is pressed upon (in the compact SCV, the cylinder is pulled upon) by the armature, completely opening the fuel passage and supplying fuel to the plunger. (Total quantity suctioned → Total quantity discharged) - When power is removed from the solenoid, the return spring presses the needle valve back to the original position, closing the fuel passage. - The solenoid ON/OFF is actuated by duty ratio control. Fuel...
Page 40
Operation Section1–35 When the SCV Energized Duration (Duty ON Time) is Long - When the energization time is long, the average current flowing to the solenoid is large. As a result, the needle valve is pushed out (in the compact SCV, the needle valve is pulled), creating a large valve opening. Subsequently, the fuel suction quantity increases. Q002344E Needle Va l v eLarge Opening SCV Feed Pump Conventional SCV Q002324 E Large Valve Opening Compact SCV Needle Va l v eSCV Feed Pump