11 Position the valve downward and provide tubing so that any discharge will exit only within 6 inches (153 mm) above, or at any distance below the structural floor. Be certain that no contact is made with any live electrical part. The discharge opening must not be blocked or reduced in size under any circumstances. Excessive length, over 30 feet (9.14 m), or use of more than four elbows can cause restriction and reduce the discharge capacity of the valve. No valve or other obstruction is to be placed...
Page 12
12 Converting the Lower Element These instructions only cover the conversion of the convertible element, read this entire manual before attempting to install or operate the water heater. The water heater is factory set to operate at 3800 watts. The lower element can be converted to operate at 5500 watts. Refer to “Facts to Consider About the Convertible Lower Element” section. The Upper Element, (if double element model) is a conventional 3800 watt element which only operates at its rated wattage on 240...
Page 13
13 FIGURE 16. 5. Remove the screws from terminal 2 of the element, and move the looped end of the wire aside. FIGURE 17. 6. The buss bar is labeled 5500 W. Place the buss bar over terminals 2 and 3 with the 5500 W visible. Install the extra screw provided into terminal 3. FIGURE 18. 7. The wire removed from terminal 2 has a looped end. It must remain looped and now be placed (as shown) on top of the buss bar, over the opening of terminal...
Page 14
14 11. Replace the access panel. FIGURE 21. 12. Complete wiring to the water heater, or if completed, turn “ON” electric power to the water heater after filling the tank with water. FIGURE 22. Never use this water heater unless it is completely full of water. To prevent damage to the tank and heating element, the tank must be filled with water. Water must flow from the hot water faucet before turning “ON” power. Wiring You must provide all wiring of...
Page 15
15 5. Wiring Diagrams (see “Wiring Diagrams” section) have been supplied showing the two most common types of connections between the water heater and the power supply. You can easily see which type connection you have by removing the junction box cover on top of the water heater. •Two Wire Connection Diagrams: is the most common requiring you to simply connect red to red, black to black, and the ground wire to the green ground screw in the junction box of the water heater. •Three Wire Connection...
Page 16
16 Wiring Diagrams FIGURE 25. STANDARD WIRING FOR 2 WIRE LEAD WATER HEATERS NON-SIMULTANEOUS OPERATION 240 VOLT DOUBLE ELEMENT WIRING FOR 3 WIRE LEAD WATER HEATERS NON-SIMULTANEOUS OPERATION 240 VOLT DOUBLE ELEMENT *NOTE: Some lower Hi-Temp Limit Switches may have 4 terminals. Use only the 2 terminals on left.FIGURE 24. A6 A9
Page 17
17 Temperature Regulation HOTTER WATER CAN SCALD: Water heaters are intended to produce hot water. Water heated to a temperature which will satisfy clothes washing, dish washing, and other sanitizing needs can scald and permanently injure you upon contact. Some people are more likely to be permanently injured by hot water than others. These include the elderly, children, the infirm, or physically/mentally handicapped. If anyone using hot water in your home fits into one of these groups or if there is a...
Page 18
18 NOTE: It is not necessary to adjust the upper thermostat. However, if it is adjusted above the factory set point of 120°F (49°C), it is recommended that it not be set higher than the lower thermostat setting. The upper and lower thermostats are adjustable if a different water temperature is desired. Read all warnings in the “Temperature-Regulation” section before proceeding. 1. Turn “OFF” the electric power to the water heater at the junction box. 2. Take off the upper and/or lower access panel,...
Page 19
19 The water heater should be drained if being shut down during freezing temperatures. Also, periodic draining and cleaning of sediment from the tank may be necessary. 1. Before beginning turn “OFF” the electric power supply to the water heater. 2. CLOSE the cold water inlet valve to the water heater. 3. OPEN a nearby hot water faucet and leave open to allow for draining. 4. Connect a hose to the drain valve and terminate to an adequate drain or outdoors. 5. OPEN the water heater drain valve to allow for...
Page 20
20 1. Before beginning turn “OFF” the electric power supply to the water heater. FIGURE 30. 2. Turn off the water supply to the water heater at the water Shut-off valve or water meter. FIGURE 31. 3. Attach a hose to the water heater drain valve and put the other end in a floor drain or outdoors. Open the water heater drain valve. Open a nearby hot water faucet which will relieve pressure in the water heater and speed draining. FIGURE 32. The...