Page 31
27 5SCAN OPERATION Programmed scan Programmed scan automatically searches for signals within a specified frequency range. For programmed scan, scan edges must be programmed in advance. See the next section for details. DUsing the multi-function receiver screen qMake sure the squelch is set to the threshold point. (closed condition) wClick the [SET] button to call up the setting screen if it is not displayed. eClick the [Program SCAN] tab to show the program list. rSelect a programmed scan range to be...
Page 32
28 5SCAN OPERATION Setting scan edges Settings such as frequency range, receive mode, tuning step, etc. must be set in advance. Up to 20 settings can be pro- grammed. qCall up the setting screen if it is not displayed. •For the multi-function receiver screen, click the [SET] button. •For the simple function receiver screen, click the [MENU] button and select the ‘Function Setting (SET).’When the scan controller screen is in use, click the [SET] button on the screen. wClick the [Program SCAN] tab to show...
Page 33
29 5SCAN OPERATION Auto memory write scan Auto memory write scan does the same as the programmed scan and then writes paused signal frequencies into memory channels of a specified memory bank. Scan edges must be programmed in advance. (p. 28) DUsing the multi-function receiver screen qMake sure the squelch is set to the threshold point. (closed condition) wClick the [SET] button to call up the setting screen if it is not displayed. eClick the [Program SCAN] tab to show the program list. rSelect the...
Page 34
30 5SCAN OPERATION Memory scan This function searches all memory channels in a selected memory bank. DUsing the multi-function receiver screen qMake sure the squelch is set to the threshold point. (closed condition) wClick the [BANK ∧] or [BANK∨] button to select the de- sired memory bank. •When using the memory list screen, click [BANK#]/[BANK$] or select a bank name with [$] to select a memory bank. eClick the [SET] button to call up the setting screen if it is not displayed. rClick the [Memory SCAN]...
Page 35
31 5SCAN OPERATION Versatile memory scan Using the [Memory SCAN] tab in the setting screen you can set conditions specific only to memory channels during mem- ory scan. qCall up the setting screen if it is not displayed. •For the multi-function receiver screen, click the [SET] button. •For the simple function receiver screen, click the [MENU] button and select the ‘Function Setting (SET).’When the scan controller screen is in use, click the [SET] button on the screen. wClick the [Memory SCAN] tab. eMake...
Page 36
32 5SCAN OPERATION Scan resume condition When receiving a signal, scan automatically pauses on that signal. The scan resume condition sets the time that the scan pauses before resuming or whether scan stops instead of pausing. qCall up the setting screen if it is not displayed. •For the multi-function receiver screen, click the [SET] button. •For the simple function receiver screen, click the [MENU] button and select the ‘Function Setting (SET).’When the scan controller screen is in use, click the [SET]...
Page 37
33 5SCAN OPERATION Scan speed setting The searching speed of frequencies or memory channels is variable. DUsing the multi-function receiver screen ➥Click the [SPEED] control with the sub mouse button to in- crease the scan speed; click the [SPEED] control with the main mouse button to decrease the scan speed. •When clicking and holding the control, the scan speed scrolls up or down. DUsing the simple function receiver screen qCall up the scan controller screen if it is not displayed. •Click the [MENU]...
Page 38
34 6BAND SCOPE Operation The band scope function allows you to visually check a spec- ified frequency range. Receive audio is muted while monitoring the band scope. Push [s/❙❙] to pause sweeping and receive the audio. DUsing the multi-function receiver screen qClick the sweep start/pause button ([s/❙❙]) to begin a sweep; signal conditions appear starting from the center of the range. •Conditions over the entire set frequency span can be observed around the center frequency of the currently received...
Page 39
35 6BAND SCOPE tClick the waveform to select the frequency of the signal. •Click the [s/❙❙] button to pause a sweep and monitor the fre- quency. Repeat to resume the sweep. •While pausing the band scope, you can also select the frequency by clicking the waveform. The current receive frequency is marked by a dotted line and the previous receive frequency is displayed at center. yClick the close ([]) button to stop sweeping and close the band scope screen. Changing the automatic sweep step limit The...
Page 40
36 7TONE SQUELCH OPERATION The tone squelch opens only when receiving a signal con- taining a matching subaudible tone in FM mode. For exam- ple, you can silently wait for calls from group members using the same tone in an amateur band. DUsing the multi-function receiver screen qClick the [FM] button to select FM mode. wClick the [T-SQL] button to bring up the [TONE SQUELCH] dialog box. •“T-SQL”appears in the function display. eClick the [$] button, then select the desired tone squelch frequency....