13WIRELESS OPERATION 56 DKeypad KEYFUNCTIONSECONDARY FUNCTION (After )FUNCOTHER FUNCTIONS Calls up a call channel.No secondary function. •After : Input the appropriate digit for frequency or memory channel selection. •After : Transmit the appropriate DTMF code. •After : Transmit the appropriate DTMF memory contents. [0] to [9], [A] to [D] can be used for DTMF memory. DTMF MEMO DTMF KEY D ENT DEMO Selects memory mode.No secondary function. Selects VFO mode.Turns the one-touch PTT function ON and OFF. Selects high output power.No secondary function. Selects mid-high output power.No secondary function. Selects low output power.Turns the DTMF memory function ON. Selects –duplex.Turns the subaudible tone encoder ON. Selects + duplex.Turns the pocket beep function ON. Selects simplex.Turns the tone squelch function ON. Mutes audio signals.Starts and stops a priority watch. AFC CALL 1 AFC-OFF 2 MR PTT-M 3 VFO PGR 4 HIGH 5 C-SQL MID 6 DTMF LOW 7 DUP– TONE 8 DUP+ T-SQLS 9 SIMP T-SQL 0 MUTE PRIO
13WIRELESS OPERATION 57 KEYFUNCTIONSECONDARY FUNCTION (After )FUNCOTHER FUNCTIONS Clears a digit before entry. Cancels the scan, priority watch, or DTMF memory function.Writes the VFO contents into the memory channel or call channel. Advances the memory channel number when continuously pushed after program- ming is completed. •After : Transmit the appropriate DTMF code. [B MONI] Transmits a 1750 Hz tone call signal for 0.5 sec. [A SQL] Transmits a 1750 Hz tone call signal while pushing.DTMF KEYEnters set mode and advances the set mode selection order.Turns the DTMF memory function OFF. Decreases the set mode selection order after entering set mode. NOTE: The IC-207H has no voice synthesizer function.Turns the subaudible tone encoder, pocket beep or tone squelch OFF. Sets the keypad for numeral input.Enters and exits demonstration mode. Toggles between opening and closing the squelch.Starts and stops scanning. Selects 1 of the 4 preset squelch levels.Locks all the keys on the microphone key- pad. MW A CLR B D-OFF SET C SPCH T-OFF D ENT DEMO M SCAN MONI # SQL REAR LOCK
13WIRELESS OPERATION 58 Microphone address The transceiver has 8 possible microphone addresses (in- cluding OFF) to help prevent interference from other HM-90 WIRELESS MICROPHONES. Set both the microphone address and microphone dip switch to the same value as follows. NOTE:When the supplied microphone is connected, the transceiver rejects control signals from the HM-90 even when the microphone address is matched. DMicrophone address ➀Push [PWR] to turn power OFF. ➁While pushing [SET], turn power ON to enter initial set mode. ➂Push [SET] a few times to select the “Adr” display as shown at right. ➃Rotate the tuning dial to set the microphone ad- dress to 0–7 or to turn the microphone control OFF. •When “Adr-oF” is selected, the transceiver rejects all control sig- nals from the HM-90. ➄Push [PWR] momentarily to exit initial set mode. USINGINITIAL SET MODE The display shows the mi- crophone address is set to 2. DMicrophone dip switch ➀Remove the switch cover from the microphone rear panel. ➁Set the microphone dip switch and the microphone ad- dress to the same value as shown below. ➂Replace the switch cover. MICROPHONE ADDRESSDIP SWITCH S1–1S1–2S1–3 Adr-0OFFOFFOFF Adr-1 (default)ONOFFOFF Adr-2OFFONOFF Adr-3ONONOFF Adr-4OFFOFFON Adr-5ONOFFON Adr-6OFFONON Adr-7ONONON LOCK AFC AFC-OFF PTT-M MW PGR CALL 123A 456BMR VFO CLR C-SQL DTMF D-OFF HIGH MID LOW SET Dip switch ON OFF 1 2 3 (S1) Switch cover
OTHER FUNCTIONS14 59 Beep tones on/off You can select silent operation by turning beep tones OFF or you can select to have confirmation beeps sound at the push of a switch by turning beep tones ON. ➀Push [PWR] to turn power OFF. ➁While pushing [SET], turn power ON to enter initial set mode. ➂Push [SET] one or more times until “bEP” appears. •Pushing [MONI] reverses the order of selection. ➃Rotate the tuning dial to select the condition. •“bEP-oF”: Beep tones are turned OFF. •“bEP-on”: Beep tones are turned ON. ➄Push [PWR] momentarily to exit initial set mode. Time-out timer To prevent accidental prolonged transmission with the one- touch PTT function, etc., the transceiver has a time-out timer. This timer cuts a transmission OFF after 3, 5, 15 or 30 min. of continuous transmission. This timer can be cancelled (de- fault). Approx. 10 sec. before the time-out timer passes, the trans- ceiver emits a beep tone as a warning. ➀Push [PWR] to turn power OFF. ➁While pushing [SET], turn power ON to enter initial set mode. ➂Push [SET] one or more times until “tot” appears. •Pushing [MONI] reverses the order of selection. ➃Rotate the tuning dial to select the desired time-out time or turn the timer OFF (“oF”). ➄Push [PWR] momentarily to exit initial set mode. USINGINITIAL SET MODEUSINGINITIAL SET MODE The display shows that the 5 min. timer is selected.The display shows that the time-out timer is cancelled. TOT The display shows that the beep tones are turned ON.
14OTHER FUNCTIONS 60 Auto power-off The auto power-off function conveniently turns the transceiver power OFF after a preset time in which no operations are per- formed. In this way, when you forget to turn the power OFF, the transceiver automatically turns itself OFF, thereby con- serving battery power. The time can be set to 30 min., 1 hr., 2 hrs. or turned OFF. The selected time is retained even when the transceiver is turned OFF via the auto power-off function. To cancel the function, select “oF” in step ➃below. ➀Push [PWR] to turn power OFF. ➁While pushing [SET], turn power ON to enter initial set mode. ➂Push [SET] one or more times until “PoF” appears. •Pushing [MONI] reverses the order of selection. ➃Rotate the tuning dial to select the desired auto power-off time or turn the timer OFF (“oF”). •“AO” appears when an auto power-off time is set. ➄Push [PWR] momentarily to exit initial set mode. Cooling fan setting The transceiver has a heatsink and cooling fan to radiate heat. The cooling fan automatically turns ON while transmit- ting and remains ON for 2 min. after transmitting. The cool- ing fan can be activated continuously, if desired. ➀Push [PWR] to turn power OFF. ➁While pushing [SET], turn power ON to enter initial set mode. ➂Push [SET] one or more times until “FA n” appears. •Pushing [MONI] reverses the order of selection. ➃Rotate the tuning dial to set the cooling fan to automatic (“At”) or continuous (“on”). ➄Push [PWR] momentarily to exit initial set mode. USINGINITIAL SET MODEUSINGINITIAL SET MODE The display shows that the 30 min. timer is selected. AO The display shows that the cooling fan is set for automatic operation.The display shows that the cooling fan is set for continuous operation.
14OTHER FUNCTIONS 61 Microphone [F-1]/[F-2] keys Switches on the transceiver’s front panel can be assigned to the microphone’s [F-1] and [F-2] keys. ➀Turn power OFF. ➁While pushing the desired switch on the transceiver and [F-1] or [F-2] on the microphone, turn power ON. •The switches’ function is programmed into the key ([F-1] or [F-2]). •Default setting The following functions are assigned to the [F-1]/[F-2] keys when first applying power or after CPU resetting: [F-1]: selects output power; push and hold to select duplex setting [F-2]: selects a tone function or none at all; push and hold to start/stop tone scan Display dimmer Adjust to suit lighting conditions and personal preference. ➀Push and hold [SET] one or more times until “d-1”–“d4” ap- pears as follows. •Pushing [MONI] reverses the order of selection. ➁Rotate the tuning dial to set the desired intensity. •Intensity can be set from “d1” (dark) to “d4” (bright). ➂Push [V/MHz] to return to normal operation. USINGSET MODE HI19 5 The display shows the display backlighting set to brightest.
14OTHER FUNCTIONS 62 Squelch delay During operation, received signal strength often fluctuates. This can result in annoying repeated opening and closing of the squelch during reception of the same signal. The IC-207H has a built-in squelch delay function which helps prevent this. When both stations are operating from a fixed location, this function should be set to “short” e.g. packet operation. ➀Push [PWR] to turn power OFF. ➁While pushing [SET], turn power ON to enter initial set mode. ➂Push [SET] one or more times until “Sqt” appears. •Pushing [MONI] reverses the order of selection. ➃Rotate the tuning dial to set the squelch delay to “L” (long) or “S” (short). ➄Push [PWR] momentarily to exit initial set mode. USINGINITIAL SET MODE The display shows the squelch delay function is set to short. Demonstration display A demonstration function is available at power ON. This func- tion gives you a quick visual introduction to the function dis- play indicators. ➀While pushing [BAND], push [PWR] to turn power ON. •The transceiver cycles through a visual tour of the function dis- play indicators. ➁Push any switch to exit demonstration mode and enter the normal operating condition temporarily. NOTE:The transceiver automatically returns to demon- stration mode after 2 min. in which no operations are per- formed. To deactivate the demonstration display permanently, turn power OFF, then while pushing [BAND], turn power ON again.
14OTHER FUNCTIONS 63 Packet operation DData speed For packet operation the transceiver can be set to one of two data speeds: 1200 bps (default) or 9600 bps. ➀Push [PWR] to turn power OFF. ➁While pushing [SET], turn power ON to enter initial set mode. ➂Push [SET] one or more times until “bPS” appears. •Pushing [MONI] reverses the order of selection. ➃Rotate the tuning dial to select the desired data speed. ➄Push [PWR] momentarily to exit initial set mode. USINGINITIAL SET MODE The display shows the data speed set to 1200 bps. The display shows the data speed set to 9600 bps. NOTE: For 1200 bps operation— •Disconnect the microphone plug from the microphone connector during data transmission, otherwise the data signal and voice signal are simultaneously transmitted. For 9600 bps operation— •When the transceiver is set for 9600 bps data transmis- sion in INTIAL SET MODE, the microphone signal is au- tomatically cut. Therefore, it is not necessary to disconnect the microphone plug from the connector in this case. •When pushing [PTT] during data transmission, data transmission is interrupted and voice signals have prior- ity.
NOTE: •Read the instructions supplied with your TNC carefully before attempting packet operation with the IC-207H. •Pin tAF OUT is for 1200 bps operation only. This pin cannot be used for 9600 bps operation. •Over modulation may degrade signal quality. If you find that many transmissions are failing, re-adjust the modu- lation level. 14OTHER FUNCTIONS 64 D1200 bps packet operation qConnect the IC-207H and a TNC as illustrated below. wSet the TNC for transmit. eSet transmit delay on the TNC to 30–50. rAdjust the TNC frequency deviation if necessary. •When using a deviation meter: Adjust the output of the TNC so that frequency deviation is in the range ± 3 to 4 kHz. •When NOT using a deviation meter: A receiver or transceiver is needed to monitor the transmission— compare the received audio output level when receiving a TNC modulated signal with high level voice signals using the micro- phone. Then adjust the TNC modulated signal to a lower level than the voice modulated signal. D ATA I N SQL PTT RX AUDIO GND TX AUDIO TNC SIDE GND PTTP SQ AF OUT
14OTHER FUNCTIONS 65NOTE: •When using the PTTP terminal for packet operation, no voice signals are transmitted from the microphone. •When pushing [PTT] during data transmission, data transmission is interrupted and the voice signal takes pri- ority. •Read the instructions supplied with your TNC carefully before attempting packet operation with the IC-207H. •Pin rDATA OUT is for 9600 bps operation only. This pin cannot be used for 1200 bps operation. D9600 bps high speed packet operation The IC-207H supports 2 modes of 9600 bps packet opera- tion: G3RUH and GMSK. qConnect the IC-207H and a TNC as illustrated below. wG3RUH mode can handle 16 kinds of modulated wave forms in order to maintain a communication link. eSet the TNC’s TX DELAY to 30–50. rAdjust the TNC frequency deviation if necessary (see page at right). D ATA I N SQL PTT RX AUDIO GND TX AUDIO TNC SIDE GND PTTP SQ DATA OUT