Home > Husqvarna > Blower > Husqvarna X Series 125bvx Manual

Husqvarna X Series 125bvx Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Husqvarna X Series 125bvx Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 35 Husqvarna manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							 
    125B   125B                        125BVX-SERIES            X-SERIES         
    EN 2-20
    FR 21-40
    ES 41-60 
    						
    							English --- 2
    115277126 Rev. 2 5/1/10
    CONTENTS
    Contents
    Introduction 2
    ...................
    Key to symbols 3
    ..................
    Safety instructions 4
    ...............
    Description 6
    .....................
    Fuel handling 11
    ....................
    Start and stop 12
    ...................
    Using the blower 13
    .................
    Maintenance 16
    ....................
    Technical data 19
    ...................
    WARNI NG :Under no circum-
    stances may the design of the
    machine be modified without the
    permission of the manufacturer.
    Always use genuine accessories.
    Non -- authorized modifications
    and/or accessories can result
    in serious personal injury or the
    death of the operator or others.
    Your warranty may not cover
    damage or liability caused by the
    use of non -- authorized accesso-
    ries or replacement parts.
    Note the following before
    starting:
    Husqvarna AB has a policy of continuous
    product development and therefore
    reserves the right to modify the design and
    appearance of products without prior
    notice. Long-- term exposure to noise can
    result in permanent hearing impairment.
    Always use approved hearing protection.
    This operator’s manual describes in detail
    how to use and service the blower and
    how to carry out regular maintenance. It
    also describes which measures should be
    taken to achieve maximum safety while
    operating the blower, how the safety de-
    vices work and how they should be ser-
    viced.
    Note! The section of the manual that deals
    with safety, must be read and understood
    by all persons who come in contact with
    the blower.
    This operator’s manual has been written
    for those who need guidance when it
    comes to fault tracing, thorough servicing
    and carrying out corrective maintenance of
    the blower.
    There are warning symbols on the blower.
    Should any of the warning symbols on the
    blower become disfigured or worn, new ones
    should be ordered and fitted to the blower as
    soon as possible. Note that some of the
    warning symbols may be molded in certain
    components of the blower.
    The blower is used for blowing away
    leaves and other debris on the ground.
    When operating the blower, the operator
    must stand with both feet firmly on the
    ground. 
    						
    							English --- 3
    115277126 Rev. 2 5/1/10
    KEY TO SYMBOLS
    Checks and/or main-
    tenance shall be
    carried out after
    having switched off
    the engine and discon-
    nected the spark plug.
    Cleaning at regular
    intervals is required.
    Approved protective
    goggles or visor must
    be worn.
    Approved protective
    goggles or visor, ear
    protection, and face
    mask in dusty environ-
    ments must be worn.
    WARNING! The blow-
    er can be dangerous!
    Careless or improper
    use can cause seri-
    ous, even fatal injury.
    Read the operator’s
    manual carefully and
    make sure that you
    understand the
    contents before using
    the blower.
    WARNING! Make sure
    that the inlet cover is
    locked in the closed
    position or that the
    vacuum tube is mount-
    ed on the blower. Never
    touch the impeller un-
    lesstheunitisoff,the
    impeller has stopped
    moving and the spark
    plug is disconnected.
    Always wear approved,
    protective gloves. The blower operator
    must make sure that
    no bystanders or
    animals come nearer
    than 15 meters.
    Whenever several
    operators are working
    inthesameworkarea,
    they should maintain a
    safe distance of at
    least 15 meters from
    one another.
    Choke
    Refueling
    Stop switch
    Instructions on how to
    open the inlet cover.
    This product is in ac-
    cordance with applica-
    ble EC directives.
    Noise pressure level
    measured at 7,5 metres
    distance.
    Noise emission to the
    environment according
    to the European
    Community’s Directive.
    The machine’s emis-
    sion is specified in the
    Technical data section
    andonthe
    label.
    Other symbols/decals on the machine
    refer to special certification requirements
    for certain markets.
    X
    X
    X
    XX
    XX XX
    X X
    X
    X
    XX
    XX
    XX
    WA R N I N G ! The blower
    may throw objects at
    high velocity that can
    ricochet and hit the
    operator. This may
    cause serious eye
    damage.
    XX
    X
    X
    XX 
    						
    							English --- 4
    115277126 Rev. 2 5/1/10
    SAFETY INSTRUCTIONS
    MufflerThe muffler is designed to give the lowest
    possible noise level and to direct the en-
    gine’s exhaust fumes away from the opera-
    tor. Mufflers fitted with catalytic converters
    are also designed to reduce harmful ex-
    haust components.
    Safety equipment
    The blower is equipped with a number of
    safety devices and guards for the preven-
    tion of accidents. These are described in
    the general description of the blower.
    The safety devices and guards also require
    regular inspection and maintenance. These
    measures and the interval at which they
    should be carried out are specified in the
    Maintenance section.
    WARNING:The exhaust fumes
    from the engine are hot and may
    contain sparks which can start a fire.
    Never start the machine indoors or
    near flammable material!
    Fuel safety
    Special safety instructions apply to the type
    of fuel used for the blower. These instruc-
    tions are specified under the Fuel handling
    section.Personal safety equipmentPersons who use the blower shall wear the
    following safety equipment:
    1. Approved ear protection.
    2. Approved eye protection.
    3. Approved protective gloves.
    4. Boots or work shoes with a non-- slip sole.
    5. Face mask when operating the blower in dusty environments.
    Personal safetyThe following instructions apply to persons
    operating the blower:
    SThe operator shall have read and under-
    stood the contents of this manual.
    S Do not wear loose clothing, scarves or
    neckchains or let long hair hang loose,
    since these can be drawn into rotating
    parts of the blower and cause injury.
    S Do not operate the blower while under
    the influence of alcohol, drugs or when
    you are tired.
    S Do not allow minors to operate the
    blower.
    S Always have a first aid kit nearby.
    WARNING:The fuel used to run
    the blower has the following
    dangerous characteristics:
    1. Volatile liquid: its vapor and exhaust fumes are poisonous.
    2. Direct contact can cause skin irritation.
    3. It is extremely flammable.
    WARNING:Mufflers fitted with
    catalytic converters become extreme -
    ly hot during use and after stopping.
    This also applies at idling speeds.
    Contact can result in burns to the
    skin.Beawareoftheriskoffire!
    WARNING:The blower must
    never be used if any of the safety
    devices or guards are missing,
    damaged or not in working order.
    WARNING:This machine pro-
    duces an electromagnetic field du
    ring operation. Under some circum-
    stances, this field may interfere with
    active or passive medical implants.
    To reduce the risk of serious or fatal
    injury, we recommend persons with
    medical implants to consult their
    physician and the medical implant
    manufacturer before operating this
    machine. 
    						
    							English --- 5
    115277126 Rev. 2 5/1/10
    SAFETY INSTRUCTIONS
    Other safety measuresS Operate the blower only at reasonable
    hours, i.e. not early in the morning or late
    at night when people might be disturbed.
    Comply with times listed in local ordi-
    nances. Usual recommendations are 9:00
    a.m. to 5:00 p.m., Monday through Satur-
    day.
    S Operate the blower at the lowest possible
    throttle setting to do the job.
    S Check the condition of the blower before
    operation, especially the muffler, air intake
    and air filter.
    S Use a rake or a broom to loosen ground
    debris before blowing.
    S Under dusty conditions, slightly spray the
    work area with a hose.
    S Conserve water by using blowers instead
    of hoses for many lawn and garden
    applications, including areas such as roof
    gutters, screens, patios and gardens etc.
    S Watch out for children, pets, open windows
    or vehicles, and blow debris safely away.
    S Use the full nozzle extension so the air
    stream can work close to the ground.
    S After using the blower, clean up and
    dispose of debris in trash receptacles.Safety while operating the
    blower
    SThis garden blower/vacuum is only
    designed for blowing away or removal of
    leaves and other debris on the ground.
    S Do not allow bystanders or animals to be
    in the work area, i.e. 15 meters from the
    operator.
    S The blower may throw objects at high
    velocity that can ricochet and hit the opera-
    tor. This may cause serious eye damage.
    S Never point the blower nozzle toward
    people or animals.
    S Stop the engine before fitting or disman-
    tling accessories or other components.
    S Never operate the blower if any of the
    guards are missing.
    S Never operate the blower in poorly venti-
    lated spaces where exhaust fumes might
    otherwise be inhaled.
    S Stop the engine before refueling. Move
    the unit at least 3 meters from fueling site
    before attempting to start.
    S The catalytic muffler is extremely hot
    while the blower is running and after it
    has stopped. The same applies when the
    blower is running at idling speed. Be
    aware of the danger of fire, especially
    while operating the blower near flam-
    mable materials and/or where flammable
    fumes are present.
    S Be careful, particularly if left hand opera-
    tion is applied. Avoid any direct body
    contact with inlet cover area. Keep jewel-
    ry, loose clothing, or clothing with loosely
    hanging straps, ties, tassels, etc., away
    from inlet cover area.
    S Do not operate the blower while standing
    on a ladder or a stand.
    S Secure the machine during transport. 
    						
    							English --- 6
    115277126 Rev. 2 5/1/10
    DESCRIPTION
    The blower
    20
    23
    24
    13
    15
    14
    17
    19
    12
    10
    9
    8
    6
    3
    1
    4
    7
    11
    2
    1. Shoulder strap (125BVX-- SERIES) 13. Fan impeller
    2. Throttle trigger 14. Standard nozzle
    3. STOP switch 15. High velocity nozzle
    4. Variable speed control (125B
    X-- SERIESand 125BVX-- SERIES)
    5. Fan housing 16. Blower tube
    6. Fuel cap 17. Tube clamp bolt
    7. Air filter 18. Tube clamp nuts
    8. Choke 19. Muffler
    9. Primer bulb 20. Ground wire
    10. Inlet cover 21. Starter handle
    11. Vacuum handle 22. Starter device (125B
    X--SERIESand 125BVX-- SERIES) 23. Carburetor adjustment screws
    12. Cutters (125BX--SERIESand 24. Operator’s manual
    125BVX--SERIES)
    510
    21
    16
    22
    18 
    						
    							English --- 7
    115277126 Rev. 2 5/1/10
    DESCRIPTION
    Accessories (125BX--SERIESand 125BVX--SERIES)
    24
    22
    21. Vacuum device with collection components consisting of items 22-- 26 below
    22. Collection bag tube
    23. Collection bag
    24. Vacuum tube in two sections
    25. Screw
    26. Shoulder strap23
    21
    25
    26 
    						
    							English --- 8
    115277126 Rev. 2 5/1/10
    DESCRIPTION
    Safety equipmentThe following equipment on the blower is
    designed for protecting personnel and
    materials. These components should
    receive special attention whenever you
    operate, inspect and service the blower.
    Stop switchS The stop switch (A) is used to stop the
    engine.
    MufflerSThe muffler is designed to give the low-
    est possible noise level and to direct the
    engine’s exhaust fumes away from the
    operator. Mufflers fitted with catalytic
    converters are also designed to reduce
    harmful exhaust components.
    S The engine exhaust fumes are hot and
    can contain sparks, which may cause
    fire if they come in contact with dry or
    flammable material.
    S Some blower models, esp. those sold in
    countries where the climate is dry, are
    equipped with a spark arresting screen
    (B). This screen must be c leaned or re-
    placed at specific intervals. See the
    Maintenance section.
    A
    WARNING:The muffler is ex-
    tremely hot while the engine is run -
    ning and after it has stopped. DO
    NOTTOUCHTHEMUFFLERIFITIS
    HOT! This can cause severe burns.
    B
    Other equipment
    Throttle triggerS The speed and the output of the engine
    are regulated by the throttle trigger (C).
    Variable speed controlSThe variable speed control (D) is de-
    signed to allow setting engine speed as
    necessary during blower use only.
    S To avoid causing damage to the unit, DO
    NOT attempt to use the variable speed
    control during starting or during vacuum
    use.
    Fan housingSThe blower fan housing (E) and the fan
    impeller (F) provide high performance air
    discharge.
    C
    E
    F D 
    						
    							English --- 9
    115277126 Rev. 2 5/1/10
    DESCRIPTION
    Ground wireS The ground wire (G) reduces static
    build-- up during operation in dry condi-
    tions.
    Inlet coverSAn inlet cover (H) is located on the side
    of the fan housing. Opening this cover
    allows access for cleaning and inspect-
    ing the impeller ( 125B
    X-- SERIESand
    125BVX-- SERIESonly). If the vacuum tube
    is used, it must be fitted to the opening in
    the inlet cover. To open the inlet cover,
    use a tool to lift the edge of the cover
    opposite the hinge (indicated by arrow
    on inlet cover).
    Cutters(125BX-- SERIESand 125BVX--SERIES)
    S Two cutters (J) are fastened to the impel-
    ler. The cutters are there to mulch leaves
    and other debris that have been vacuumed
    before they enter the collection bag.
    Blower tube and nozzleSThe blower tube (K) has a pegged slot
    mounting system to the unit. To install
    or remove the blower tube (or collection
    bag tube for the 125BV
    X-- SERIES), loosen
    the tube clamp bolt (do not remove nuts
    from bolt). Align slot in the blower air
    outlet with the raised rib on the tube
    and insert tube. Tighten tube clamp bolt.
    S The nozzles (L)have a bayonet mount
    for connection to the blower tube. Air is
    channeled through the blower tube to the
    nozzles, where the air discharge velocity
    increases and the air stream discharge
    pattern is formed to provide best perfor-
    mance. The length of the blower tube
    can be adjusted by twisting the nozzle to
    the left to disengage the bayonet mount
    and sliding the nozzle to the appropriate
    position. Twist the nozzle to the right until
    a click is felt to resecure the nozzle.
    Starter device and starter handleS The starter device (M) is located on the
    side of the engine shrouding and en-
    gages the crankshaft only when the
    starter handle (N) is pulled.
    Fuel capSThe fuel cap (O) is located at the rear of
    the engine shrouding on the fuel tank
    and has a seal to prevent fuel from leak-
    ing out.
    Air filterSThe air filter (P) consists of a fiber filter
    medium in a resilient frame. The air filter
    should be cleaned at specific intervals
    (see Maintenance section). Otherwise,
    the blower will consume too much fuel,
    the performance will be reduced and an
    oily deposit may form on the spark plug
    electrodes.
    WARNING:Never start the blower
    if the inlet cover is not closed, is
    damaged or cannot be closed
    (except if the vacuum tube is fitted).
    H
    K
    J
    M
    N
    O
    P
    G
    L 
    						
    							English --- 10
    115277126 Rev. 2 5/1/10
    DESCRIPTION
    Adjusting the carburetor
    NOTFORALLMODELS
    S There are three adjusting screws (R) for
    adjusting the carburetor:
    SLow speed jet
    S High speed jet
    S Adjustment screw for idling
    S Adjusting the carburetor involves adapt-
    ing the engine to local operating condi-
    tions, e.g. climate, altitude, gasoline and
    type of two-- stroke engine oil used. For
    details about carburetor adjustment, see
    the Maintenance section.
    R
    ChokeSThe choke (Q) is located below the air
    filter cover and should be used every
    time the engine is cold-- started.
    Q 
    						
    All Husqvarna manuals Comments (0)