Chapter 5---Troubleshooting Model 230 Service Manual5-1 5.0 Troubleshooting Contents 5.1 Status LEDs .............................................................................................5-1 5.2 Error Codes..............................................................................................5-4 5.3 Troubleshooting Guide .............................................................................5-7 5.1 Status LEDs The illustrations below indicate where various LEDs are located that indicate proper or improper operation of the System Controller, the Raster Timing Generator, the Video Processor Board, the Scan Reversal Board, the Convergence/Deflection Board, the Video Amplifier Board, the Low Voltage Power Supply, and the High Voltage Power Supply. Figure 5-1. Projector rear with cover and rear panel off.
Chapter 5---Troubleshooting 5-2Model 230 Service Manual Figure 5-2. Left side of projector with rear cover off. Figure 5-3. Right Side of projector with rear cover off.
Chapter 5---Troubleshooting Model 230 Service Manual5-3 Figure 5-4. Convergence/Deflection and Video Amplifier LEDs.
Chapter 5---Troubleshooting 5-4Model 230 Service Manual 5.2 Error Codes For certain errors that may occur in the Model 230 Projector the software provides error codes that are helpful in determining the nature of the problem. These error codes can be seen on the left side of the monitor screen when using a PC connected to Port A or Port B. Table 5-1. Error Categories: Category NumberError category Description 1 CEXEC Operating System. 2 FLASH HW Flash Memory HW driver. 3 IIC HANDLER IIC Handler for Convergence/Deflection PCB, Horizontal/Vertical Deflection PCB, Raster Timing Generator PCB, Video Amplifier PCB, Video Processor PCB. 4 POWER ON/OFF Power On Sequencing. 5 FLASH MANAGER Flash Memory Data Manager. 6 VIDEO SWITCHER EXTRON or JVC Video Switcher Handler. 7 ANSI OUTPUT Ansi Output Display process. 8 UI CHAN/SRC User Interface VIC Configuration Handler for Channel/SRC Data. 9 VIDEO INPUT CARD VIC Card Handler. 10 HARDWARE Misc HW (shutters, etc.). The error codes listed in Table 5-2 describe problems associated with software (Version 0.9.8) and hardware while the projector is operating. The first column of the table lists the error number code that appears on the PC screen. The second column describes the on-screen text. The third column provides a description of the problem and any other pertinent information. Table 5-2. Error Codes. Error NumberOn-screen text Description 1.5 “Invalid read/wrt” Software error-mismatch. Open mode vs. Write or Read command. 1.12 “Ser parity error” Serial Port Parity error-not currently used. 1.13 “Bad dev I/O oper” Software error-invalid I/O request. 1.27 “Timeout on Read” Software error-unexpected timeout
Chapter 5---Troubleshooting Model 230 Service Manual5-5 Error NumberOn-screen textDescription on Read. 1.34 “No mem available” Software error-no heap available for memory allocation. 2.1 “Invalid Sector” Software error-invalid Flash sector number. 2.2 “Write Timeout” Flash Memory Write Failure. 2.3 “Erase Timeout” Flash Memory Erase Sector Failure. 2.4 “Verify Error” Flash Memory Write Verify Failure. NOTE: Category 3 error codes may occur when power is interrupted by opening the cover interlock switches or during power brown-outs. 3.1 “Pin Timeout” IIC Slave HW protocol error- possible on each byte transfer. 3.2 “BB Timeout” IIC Slave HW protocol error-1st error possible on Read or Write. 3.3 “No Slave Ack” IIC Slave HW protocol error-missing acknowledgement on byte transfer. NOTE: This error occurs if the slave is missing. During Power On, this error is reported in the POWER category. 4.1 “CD PCA Missing” “No Slave Ack” on first poll of Convergence/Deflection PCB. 4.2 “CD PCA Not OK” /CD_OK is high (BAD). 4.3 “”HVD PCA Missing” “No Slave Ack” status on first poll of Horizontal/Vertical Deflection PCB. 4.4 “HVD PCA Not OK” HVD_OK is High (BAD)-[/HVD_OK requires RTG Timing. 4.5 “VA PCA Missing” “No Slave Ack” status on first poll of Video Processor. 4.6 “VA PCA Not OK” /VA_OK is High (BAD). 4.7 “VP PCA Missing” “No Slave Ack” status on first poll of VP. 4.8 “VP PCA Not OK” VP_OK is High (BAD) 4.9 “RTG PCA Missing” “No Slave Ack” status on first poll of RTG 4.10 “RTG PCA Not OK” RTG_OK is High (BAD) 4.14 “Lamp Startup” Lamp Failed to light (/LAMP_LIT_B
Chapter 5---Troubleshooting 5-6Model 230 Service Manual Error NumberOn-screen textDescription not Low for 3 seconds out of 20 seconds.) 4.15 “Low Voltage PS” Low Voltage PS failed (/LV_OK_B is High). 4.16 “High Voltage PS” High Voltage PS failed (/HV_OK_B is High). 4.17 “VIC1 Board Not OK” /VIC_OK is High (BAD) on VIC Slot 1. 4.18 “VIC 2 Board Not Ok” /VIC_OK is High (BAD) on VIC Slot 2 4.19 “VIC3 Board Not OK” /VIC_OK is High (BAD) on VIC Slot 3 4.20 “VIC1 Invalid Type” Software does not support VIC_ID in Slot 1 4.21 “VIC2 Invalid Type” Software does not support VIC_ID in Slot 2 4.22 “VIC3 Invalid Type” Software does not support VIC_ID in Slot 3 4.23 “Shutters Missing” One or more shutters not installed (BAD) 4.24 Lamp Start Not On /LAMP_OK is high, lamp module not installed, jumper missing, ALPS bad. No error codes in Category 5 (Flash Manager) Most Category 6 error codes indicate RS232 communication errors and apply to Switchers only. 6.1 “Sync Timeout” No Header found in data stream - possible baud rate error. 6.2 “No Char Repeat” Expected data characters to be repeated - failed. 6.3 “Invalid Format” Data not in Extron or JVC Switcher format. 7.1 “Write Len Error” Ansi Output to RS232 port was interrupted - incomplete. 8.1 “VIC Slot is empty” User has selected a Channel - VIC is not present. 8.2 “VIC Type Changed” User has selected a Channel - VIC type has changed. User may have
Chapter 5---Troubleshooting Model 230 Service Manual5-7 Error NumberOn-screen textDescription swapped a VIC into an incorrect slot. 8.3 “Interpol Blocked” Software process error - Interpolation Process not allowed to run by higher priority processes. 9.1 “Quad Dec Not Init” HW: Quad Decoder failed Startup Sequence. 10.1 “Shutter Stat BAD” One or more shutters reading wrong status. One other error may appear on the monitor screen with the statement “Assertion Failed” (only if the PC is connected to Port A). This is a very rare but serious error. If it occurs, copy the 3 lines that appear on the screen, note what occured just prior to this failure, and call Hughes-JVC. 5.3. Troubleshooting Guide Table 5-2 shows some common projector problems, what to check when problems occur, possible solutions and the section in this Service Manual (If User’s Guide contains pertinent information, the appropriate section will be given) that provides some related information on the problem. Table 5-3. Troubleshooting Guide. Problem Check Possible solution Section No PowerMain Circuit Breaker on Projector rear panel.Reset Circuit Breaker. Main Circuit Breaker fails when reset.Verify input power is correct. Replace defective Low Voltage Power Supply or Arc Lamp Power Supply.4.5 and 4.6 Power Interlock Switch Test switch operation. If defective, replace switch. Projector cover not enabling interlock switch?Reposition projector cover. 4.2 No PictureCorrect channel input & VIC selected?Select correct channel and VIC.User’s Guide 4.6 Arc Lamp turned off. Restart projector. User’s Guide 4.3. System power turned off.Restart projector. User’s Guide 4.3. Signal source Verify signal source is turned on and properly connected.User’s Guide 3.5.
Chapter 5---Troubleshooting 5-8Model 230 Service Manual Problem Check Possible solution Section HIDE command invoked?Unhide image with the HIDE key on the remote. One color is missing. Turn on the missing color with the HIDE key. No image or raster on one CRT.Replace defective CRT or Video Amplifier Board.4.15, 4.13 Arc LampArc Lamp will not light. Clicking noise is heard when projector is turned on.Replace worn out Arc Lamp.4.4 Clicking noise not audible when projector is turned on.LVPS, ALPS, or Ignitor faulty. Replace LVPS, ALPS, or Ignitor.4.6, 4.5, 4.4 Arc Lamp ignites but will not stay lit.Replace defective Ignitor. 4.4 Arc LampBrightness flicker or picture is very dim.Arc Lamp may have too many hours of usage. Replace Arc Lamp.4.4 Image out of focusSpacer balls not visible. Perform the Projection Lens Focus procedure.User’s Guide 5.5.15 ILA® “spacer balls” are visible but the image is fuzzy.Perform the CRT Mechanical Focus procedure.3.5 CRT focus range is limited and the image is fuzzy.Adjust the Electronic focus. 5.6 CRT focus in not effective.Ensure the ILA® assembly is installed correctly.4.16 Image blurry with shadow on right edge.Replace ILA® assembly.4.16 Characters do not appear legible.Replace ILA® assembly.4.16 CRT focus problem is limited to one color.Replace CRT. 4.15 Sensitivity Offset is set too high.Reset Sensitivity Offset. User’s Guide 5.9. 2 Picture GeometryPicture not centered or sized correctly.Repeat the Blanking, Phase, Size, and Centering procedures.User’s Guide 5.4.3, 5.4.4, 5.5.1, 5.5.2. Picture “wraparound” at left or right edge.Readjust Blanking and Phase.User’s Guide 5.4.3,
Chapter 5---Troubleshooting Model 230 Service Manual5-9 Problem Check Possible solution Section 5.4.4. Retrace lines on raster. Adjust TOP Blanking. User’s Guide 5.4.3. Image not squared. Check Geometry and readjust if necessary.User’s Guide 5.5.3, through 5.5.10. Image bowed at left/right edge or top/bottom.Check Bow, Pincushion Balance, and Pincushion adjustments.User’s Guide 5.5.3, 5.5.4, 5.5.10. Picture Linearity. Readjust Horizontal, Vertical, or Edge Linearity.User’s Guide 5.5.7, 5.5.8. XY ConvergenceLinearity is different between colors. Unable to converge.Yoke not properly set on CRT. Perform CRT Rotation procedure.3.6 Horizontal size is different between colors.Adjust horizontal coils on Scan Reversal Board.3.10 Vertical size is different between colors.Adjust vertical size pots on Horizontal/Vertical Deflection board.3.10 XY ConvergenceNot enough range in Red or Blue XY convergence.Adjust Red or Blue CENTERING to match Green.5.5.11 Picture Color BalanceRed, Green, or Blue is missing in the image.ILA® assembly bias voltage is incorrect or there is no signal-replace Video Amplifier Board.4.13 Red, Green, or Blue lacks color.Replace ILA® assembly or Video Amplifier Board.4.16, 4.13 Grey scale test pattern is correct but image color is incorrect.Readjust Contrast. User’s Guide 5.11.2 Black image is overdriven.Adjust Threshold, Black level, and Brightness.User’s Guide 5.10.2, 5.9.1, 5.11.1. Bright Red, Green, or Blue area on screenAdjust ILA® bias and shading.User’s Guide 5.7,
Chapter 5---Troubleshooting 5-10Model 230 Service Manual Problem Check Possible solution Section limited to corners or edge.5.10 Grey scale is Green in bright areas.Subtract Green Sensitivity Offset and add Red and Blue.User’s Guide 5.9.2 Grey scale is Red in bright areas.Subtract Red Sensitivity Offset and add Green and Blue.User’s Guide 5.9.2 Grey scale is Blue in bright areas.Subtract Blue Sensitivity Offset and add Green and Red.User’s Guide 5.9.2 Picture-Various ProblemsOut of focus, blurry area on image limited to Red, Green, or Blue.Clean oily spot off CRT, Prism, or Projection Lens.3.12 Small, dark line or dot in Red, Green, or Blue image.Scratch in optics or CRT burn. Replace CRT.4.15. Bubbles in Red, Green, or Blue image.Replace affected ILA® assembly.4.16. Image ghost in picture. Replace burn-in CRT or ILA® assembly4.15, 4.16 Reversed ghost image on screen.If projecting through glass, prevent light from reflecting back into the lens. Picture lacks depth of field.Adjust Contrast or Brightness.User’s Guide 5.11.2, 5.11.1 Picture-Various ProblemsImage jitter and noise. Replace Video Processor Board.4.8 Image jitter present at one source only.Replace Raster Timing Generator.4.8 Image is not level. Level the projector or rotate the CRT Yoke.3.6 “Flagwaving” at top of picture or top of image is skewed.VTR mode checked in Timing menu. Deselect VTR mode.User’s Guide 4.9 {4.Timing (5) }. Black line appears on the screen.Loss of fluid in Prism. Replace Prism.4.18 No Response when using Tether cable on the Remote.Possible defective tether cable. Terminal port not set up correctly.Replace tether cable. Select Tethered Remote and correct baud rate from menu.