Page 21
Chapter 3---Electrical Model 250 Service Manual 3-5 ! +5.1V for digital components ! +6.2V for CRT filaments ! ±15V for analog circuits ! +80V supply used by the High Voltage Power Supply, Video Amplifier PCB, and the Horizontal/Vertical Deflection PCB. LVPS - Service Adjustments There are no service adjustments for the Low Voltage Power Supply. LVPS - Remove and Replace Tools Needed: #2 Posi-drive Phillips-head screwdriver Parts Needed: Low Voltage Power Supply - p/n 102520 To remove the Low Voltage...
Page 22
Chapter 3---Electrical 3-6 Model 250 Service Manual ALPS - Inputs: AC input power: Directly from the AC Line Filter. The input range is from 220- 240 VAC, at 50/60 Hz. /LAMP_ENA - from the System Controller PCB. Turns on the ALPS. /COVER_ON - signal enabling the Arc Lamp Power Supply. /LAMP_OK - the input is jumpered at the Arc Lamp Power Supply (tied to ground) so it is always low. / = Active Low ALPS - Outputs: ! +170 VDC output during the boost phase to get Arc Lamp ignition. This supplies the...
Page 23
Chapter 3---Electrical Model 250 Service Manual 3-7 Figure 3-2 Arc Lamp Power Supply signals and voltages. ALPS - Operation: Three signals (/LAMP_ENA, /COVER_ON, and /LAMP_OK) are required in order for the Arc Lamp Power Supply to light the Arc Lamp. The /LAMP_OK (active low) input is jumpered to ground at the Arc Lamp Power Supply, so it is always low. The Arc Lamp Power Supply sends the /LAMP_OK to the System Controller PCB. The System Controller PCB then sends the /LAMP_ENA signal back to the Arc...
Page 24
Chapter 3---Electrical 3-8 Model 250 Service Manual The Arc Lamp Power Supply sends the /LAMP_LIT signal back to the System Controller when the Arc Lamp is lit. The Arc Lamp regulates its output to give a constant Arc Lamp power. If the Arc Lamp has not lit within 20 seconds (/LAMP_LIT still high), the System Controller PCB will try once more to re-initiate the sequence. If the Arc Lamp still fails to light, an error code will appear on the back panel (see section 7.22 Error Codes). The Arc Lamp Power...
Page 25
Chapter 3---Electrical Model 250 Service Manual 3-9 2. Turn the AC Circuit Breaker to the OFF position and unplug the AC Power Cord. 3. Remove the front cover (see section 6.1 Projector Covers ). 4. Remove the lower-right-side panel by removing the five Pozi-drive screws securing it. 5. Remove the five Pozi-drive screws securing the EMI Shield. Slide the shield to the left and remove it. 6. Disconnect the INPUT AC plug. 7. Disconnect the two CONTROL SIGNALS cables. The /LAMP_OK signal jumper is attached...
Page 26
Chapter 3---Electrical 3-10 Model 250 Service Manual Figure 3-4 High Voltage Power Supply I/O signals. HVPS - Inputs HVPS_SYNC - this signal is generated on the Raster Timing Generator PCB. Square wave HCT level with 50 or 33% duty cycle. The signal is synchronized to horizontal sync. /HV_ENA - The HVPS shutdown signal from the Video Amplifier PCB (/VA_OK). H_PARABOLA - The horizontal parabola from the Convergence Deflection PCB used by the Dynamic Focus Amplifier. V_PARABOLA - The vertical parabola...
Page 27
Chapter 3---Electrical Model 250 Service Manual 3-11 RGB Anode Voltage - goes directly to each CRT RGB Focus Voltage - goes directly to each CRT Arc Ground - The Arc Ground protection for each CRT from the Video Amplifier PCB. HVPS - Operation The High Voltage Power Supply has three basic functions. ! High Voltage Generation ! Focus Voltages ! High Voltage and CRT Protection High Voltage Generation - The High Voltage Amplifier section converts the +80 V from the Low Voltage Power Supply, to 25 kV, and...
Page 28
Chapter 3---Electrical 3-12 Model 250 Service Manual HVPS - Remove and Replace Tools Needed #1 Pozi-drive Phillips-head screwdriver #2 Pozi-drive Phillips-head screwdriver small Flathead screwdriver Parts Needed High Voltage Power Supply p/n 102566 To remove the High Voltage Power Supply: 1. Power off the projector by IR Remote or PC, and allow the cooling fans to run until they shut off. 2. Turn the AC Circuit Breaker to the OFF position and unplug the AC Power Cord. 3. Remove the front cover. 4....
Page 29
Chapter 3---Electrical Model 250 Service Manual 3-13 Table 3-1 HVPS - P45 I/O Pinout PIN # Description PIN # Description 1 GND (+80V) 9 +15V 2 GND (+15V) 10 -15V 3 GND (-15V) 11 G1 SUPPLY 4 GND (G1) 12 /HV_ENA 5 /HV_OK 13 V PARABOLA 6 H PARABOLA 14 H DRIVE (HVPS_SYNC 7 GND (DAF) 8 +80V Figure 3-6 High Voltage Power Supply. 5. Carefully slide the cover upward and outward to remove it. NOTE : Refer to Figure 4-5 for the remainder of this procedure. 6. Disconnect the three CRT Anode Cables. 7....
Page 30
Chapter 3---Electrical 3-14 Model 250 Service Manual 10. Disconnect P45 (“Control”) at upper left of HVPS. 11. Disconnect and label the three Focus cables. The square tabs on these cables (see Figure 3-6) may have to be lifted up. Gently pry up with a small Flathead screwdriver. 12. Remove all the cables from the slot in the cable guide located on the left side of the HVPS. 13. Verify that all plugs and cables are removed and out of the way so the HVPS is free to be removed. 14. Loosen (do not remove)...