Home > HP > Server > HPe Boot From San Configuration Guide

HPe Boot From San Configuration Guide

    Download as PDF Print this page Share this page

    Have a look at the manual HPe Boot From San Configuration Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1114 HP manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							3Bestpractices
    Considerthefollowing:
    •ForWindows,asinglepathtoasingleLUNmustbecreatedbeforestartingthebuildprocess.
    •VerifythebootorderintheserverRBSUandensurethatthebootHBAispositionedcorrectly.
    •InMicrosoftWindows2008server,ensurethattheUSBkeyispositionedbelowthehard
    driveC.
    •Whenthebuildprocessiscomplete,BFSdriverkitmustbeupgradedtothefullSmart
    Componentdriverkit.
    •Readthereleasenotesforthelatestrequiredupdates.
    •EnsurethattheHBAmanagementsoftwareversioniscompatiblewiththedriverthatis
    installed.
    •TheLinuxdriverlogsinformationaboutfabricordrivereventsthatitdetectsinthe/var/
    log/messagesfile.
    •OnlyoneLUNcanbepresentedtotheserverforinstallation.Multiplepathsareacceptable
    forRHandSLES11,butSLES10mustcontainoneLUN,onepath.
    •ForWindowsOS,aseparateBFSDriverkitmustbeavailabletobeinstalledwhenever
    requested.
    •RunthelatestreleaseversionoftheSPPbeforetheBFSprocessisstartedtoupdatethe
    serverBIOS,HBA,CNA,andLOMfirmwaretothelatestreleasedversionasrecommended
    bytheserverinstallationdocumentfortheservertypeyouareinstallingon.
    Driverinstallationandupgrade
    •TheSmartComponentcreatesalogfileaftertheinstallationiscomplete.Viewthislogfile
    toverifythattheinstallationwassuccessful.
    •Lookforanyyellowwarningflagsinthedevicemanager.
    •FromtheDeviceManager,opentheHBAdevicetoverifythatthedriverisrunningproperly.
    •Usethevendormanagementutilitytoverifythedriver,firmware,anduniversalcodeversions,
    aswellasthedriverparameters.
    Driverinstallationandupgrade11 
    						
    							4Installingtheoperatingsystem
    Emulex,QLogic,andBrocadeHBAs
    NOTE:AlthoughtheproceduresinthischapterrefertoHBAs,theyalsoapplytoallsupported
    EmulexandQLogicadapterHBA,CNA,LOM,andmezzaninecardtypes.
    Linux
    VerifythattherearemultiplepathstotheLUNSbeforeinstallingaLinuxoperatingsystem.
    NOTE:DriversfornewlyreleasedHBAofferingsmaynotappearinthebaseinstallationCD
    ofpreviousLinuxOSreleases.Inthesecasesadriverupdatedisk(DUD)mustbeloadedduring
    theinstallation.
    DUDinstallinstructions:
    1.BoottheBootRH72CD.
    2.OntheRH72installscreen,entere.
    3.OntheLinuxcommandline,enterinst.dd.
    4.PressCtrl+XtocontinuewiththeOSboot.
    OntheDUDCLIprompt:
    1.IfusingaseparateDVDdrivefortheDUD,selectthedrivenumberattheprompt.
    2.IfusingtheRemoteDesktopVirtualdrive:
    a.UnmountinstallCDimagefile.
    b.MountthedriverISOusingImagefile
    Selectthefollowingoptionsbasedonyourchoice:
    R=refresh
    #select
    C–continue
    c.Onceyouseealistofdisks,umountthedriverISO
    d.Mounttheinstalldisk.
    e.SelectRefreshtorefreshthescreenorContinuetocontinuewithinstallation.
    RedHatEnterpriseLinux
    1.Starttheinstallationoftheoperatingsystem.
    2.Providetheparameterlinuxmpathtothekernelbootline.
    NOTE:Whilecreatingpartitionsduringtheinstallationprocess,youwillseemultipath
    devices(/dev/mapper/mpath*).Createtheinstallationpartitionsusingmultipathdevices.
    Multipathingfeaturesareenabledforalltheoperatingsystempartitionscreatedonmultipath
    devicesduringinstallation.
    3.ViewtheBaseSystempackagelistandensurethatthedevice-mapper-multipath
    packageisselected.
    4.Completetheinstallationandboottheserver.
    FormoreinformationonDUDkitinstallations,seetheRedHatdocumentationontheRedHat
    website.
    12Installingtheoperatingsystem 
    						
    							SUSELinuxEnterpriseServer
    1.Selectthedeviceforinstallingtheoperatingsystem:
    •ForSLES11:
    1.SelecttheDMdevicestocreateinstallationpartitions.
    Bydefault,DMdevicesarenotlisted.TolisttheDMdevices,selectHardDisks.
    2.SelectConfigure→ConfigureMultipath→Yes→Yes.
    3.SelecttheDMdevicestocreateinstallationpartitions.
    •ForSLES10,selectSANdevicesforinstallationpartitions.
    2.Whilecreatingtheinstallationpartitions,selectoneofthefstaboptionsunderMountin
    /etc/fstabby:
    •Ifyouintendtousetheuser_friendly_nameswithdevicemappermultipathdevices,
    selectVolumelabel.
    •Ifyoudonotintendtousetheuser_friendly_nameswithdevicemappermultipath
    devices,selectDeviceID.
    3.Completetheinstallationandrebootyourserver.
    4.VerifythatthelatestsupportedDevicemappermultipathtoolspackageisinstalled.
    5.IfyoumountedtheinstallationpartitionsbyDeviceIDinStep2,ensurethatyousetthe
    user_friendly_namestonointhe/etc/multipath.conffile.
    Windows
    InstallingfromtheMicrosoftCD
    UsethefollowingprocedurestoinstalltheoperatingsystemusingtheMicrosoftCD.
    LoadingtheHBAdriverforaMicrosoftWindowsServer2003install
    Toloadthedriver:
    1.InserttheHPESmartSetupCD.
    2.FromtheEBSUmenu,selectBootableDVD,andthenpressEnter.
    3.SelectLoadOEMBootdriverorpressBtodisplaytheLoadOEMBootDriverwindow.
    4.SelecttheFibreChannelHBA,andthenpressEnter.
    5.PressTabonce,andthenpressEntertoloadthedriver.
    Thesystemdisplaysamessageconfirmingthatthedriverisloaded.
    6.SelectExitorpressXtoexit.
    InstallingtheMicrosoftWindowsServer2003operatingsystem
    ToinstalltheMicrosoftWindowsServer2003operatingsystem:
    Procedure1
    1.WiththeMicrosoftWindowsServer2003CDintheDVDdrive,selectBootableDVD.Press
    anykeytobootfromtheCDandstarttheinstallationprocess.
    NOTE:DonotpressF6toloadanymass-storagedevicedrivers.
    2.Whentheinstallationcompletes,usethelatestSmartSetupCDtoupdatethesystemdrivers
    andagents.
    3.Tore-installtheHBAdriver,runtheSmartComponentbyselectingDrivers→DriverforFC
    HBA.
    ThissetstheHewlettPackardEnterprise-supportedregistryparameters.
    Emulex,QLogic,andBrocadeHBAs13 
    						
    							NOTE:Forsingle-pathconfigurations,skipStep4.
    4.Installmultipathingsoftware.
    5.Reboottheservertocompletetheinstallation.
    6.CompletetheinstallationandconnectotherHBAs,ifthereareany.
    InstallingtheMicrosoftWindowsServer2008operatingsystem
    ToinstalltheMicrosoftWindowsServer2008operatingsystem:
    1.WiththeMicrosoftWindowsServer2008CDintheDVDdrive,selectBootableDVD.Press
    anykeytoboottheCDwhichstartstheinstallationprocess.
    2.Whenprompted,clickCustom(Advanced)toinstallacleancopyofWindows.
    3.Browsetotheappropriatedriverfolder.
    4.Selectthediskonwhichyouwanttoinstalltheoperatingsystem,andthenclickNext.
    5.UsethelatestSmartSetupCDtoupdatethesystemdriversandagents.
    NOTE:Forsingle-pathconfigurationsskipStep4andStep6.
    6.Installmultipathingsoftware.
    7.Reboottheserver.
    8.Formultipathconfigurations,returntotheHBABIOSutilityandcompletetheconfiguration
    ofthesecondaryandtertiarybootpaths.
    9.Rebootthesystem.
    VMware
    1.InserttheESXiinstallerCD/DVDintotheCD/DVD-ROMdriveorinserttheInstallerUSB
    flashdrive.Restartthemachineandfollowtheonscreenprompts.
    2.VMwareVMvisorBootMenuappears.SelectESXiinstallerandpressEnter.
    3.VMwareESXiInstallationMenuappears.PressEntertocontinue.
    4.AcceptVMwareEULAappears.PressF11toaccept.
    5.SelectaDisktoInstallVMwareESXiappears.LocateandselecttheconfiguredinAdapter
    BIOSandpressEnter.
    6.SelecttheappropriatelayoutofthekeyboardandpressEnter.
    7.Entertherootpassword,ensurethatpasswordmustmatch.PressEntertocontinue.
    8.PressF11toconfirmtheinstallation.Installationiscomplete.
    9.RemovetheinstallationmediaandpressEntertoreboot.
    NOTE:ForspecificESX/ESXi3.x,4.x,and5.xinstallationdocumentation,seehttp://
    pubs.vmware.com/.
    Citrix
    ForprocedurestoinstallCitrixXenServer,seetheversion-specificCitrixXenServerinstallation
    guideavailableathttp://support.citrix.com/productdocs/.
    QlogicEthernetCNAs
    Linux
    VerifythattherearemultiplepathstotheLUNsbeforeinstallingaLinuxoperatingsystem.
    14Installingtheoperatingsystem 
    						
    							RedHatEnterpriseLinux
    1.Anacondaimageupdates.
    ForRHEL6.3,twooptionsareavailable
    1.ForRHEL6.3,FCoEbootfromSANrequiresanupdatedAnacondaimage.Theupdated
    imageisprovidedbyRedHatatthefollowinglocation:http://
    rvykydal.fedorapeople.org/updates.823086-fcoe.img
    ForRHEL6.3,ontheinstallationsplashscreen,pressTabandinthebootcommand
    lineadd’ddupdates=’options.Fordetails
    aboutinstallingAnacondaupdateimage,seeRedHatInstallationGuide
    Section28.1.3https://access.redhat.com/site/documentation/en-US/
    Red_Hat_Enterprise_Linux/6/html-single/Installation_Guide/
    index.html#sn-boot-options-update
    2.ForRHEL6.3,ontheinstallationsplashscreenclickTab.Inthebootcommandline
    addthe'dd'option.WhenaskedforBasicStorageDevices/Specializedstorage
    devices,selecttheSpecializedStorageDevicesmenuthenswitchAnacondagraphical
    installertovirtualterminalCLIusing(Ctrl+Alt+F2)andenterthefollowingcommands
    beforesearchingforFCoEtargets(ReplaceethXwithnameofbootinterfaceport):
    #ifconfigethXup
    #fipvlan-c-s-f"-fcoe"ethX
    SwitchbacktoAnacondainstallerusingCtrl+Alt+F6andproceedtosearchforFCoE
    targetsusingspecializedstoragedeviceoption.
    ForRHEL6.4,updatedAnacondaisnotrequired.Ontheinstallationsplashscreen,press
    Tabandinthebootcommandline,add'dd'optiontobootthecommandline.
    2.PressEntertoproceed.
    3.Whenamessage‘Doyouhaveadriverdisk’appears,enterYes.
    4.Followtheon-screeninstructionstochoosetheDriverUpdatemediumandloadan
    appropriateDUDdriverkit.
    NOTE:TheDUDdriverkitcanbefoundasapartofSPPkit.
    5.Proceedwithinstallationafterthedriversareloaded.
    6.SelectSpecializedStorageDevicesandthenclickNext.
    7.ClickAddAdvancedTarget.
    8.SelectAddFCoESANandclickAddDrive.
    9.SelecteachinterfaceintendedforFCoEboot,clearUseDCB,selectUseautovlan,and
    clickAddFCoEdisk(s).
    10.EnsurethatallFCoE-visibledisksareseenunder‘MultipathDevices’or‘OtherSAN
    Devices’orboth,asappropriate.
    11.Repeatsteps8to10forallinitiatorports.
    12.ClickNextandcompletetheinstallation.
    13.Thesystemrebootsafterinstallationiscomplete.
    14.Afterinstallation,attheRHELinstallerpromptforaninitialreboot,pressCtrl+Alt+F2to
    enterashell.Edit/mnt/sysimage/boot/grub/menu.lstandplace
    bnx2x.disable_tpa=1intothedefaultkernelcommand.
    QlogicEthernetCNAs15 
    						
    							15.Afterbooting,ensurethatallbootpathdevicesaresettostartatboottime.
    TIP:Tostartallbootdevicesattheboottime,Setonboot=yesundereachnetworkconfig
    filein/etc/sysconfig/network-script/
    NOTE:ForRHEL6.4only,edit/boot/grub/menu.lst.
    1.Deleteall“fcoe=:nodcb”parametersfromthe“kernel/
    vmlinuz...”line.TheremustbeasmanyFCoE=parametersastherewereFCoE
    interfacesconfiguredduringinstallation.
    2.Insert“fcoe=edd:nodcb”tothe“kernel/vmlinuz...”line.
    NOTE:ForRHEL6.3andRHEL6.5only,editthekernelcommandline.Next,whenthe
    systemboots,edit/boot/efi/EFI/redhat/grub.confasfollows:
    Replacethefcoe=edd:nodcbparametersfromthekernel/vmlinuz...linewithsingle
    fcoe=:nodcbforthebootinterfacewhichwasconfiguredduringinstallation.
    OnaccountofaknownlimitationwithRHEL6.3,RHEL6.4,andRHEL6.5,thehostwillonly
    bootfromthelastinterfacelistedinthekernelcommandline.
    SUSELinuxEnterpriseServer
    HPEGen9serverinstallation:
    FollowtheHPEProLiantGen9–Seriesservers(alsoDL580Gen8server)installationinstructions
    fromtheLink.
    Afteryouhavecompletedthesteps,proceedtostep4.
    1.BootfromSLES11SP2/SP3installationmediumandpressF6ontheinstallationsplash
    screenfordriverupdatedisk.SelectYes.Inbootoptions,typewithfcoe=1.Select
    Installationtoproceed.
    2.Followtheon-screeninstructionstochoosetheDriverUpdatemediumandloadan
    appropriateDUDdriverkit.
    3.Afterthedriverisupdated,selectNexttocontinuewiththeinstallation.
    4.Whenrequested,clickConfigureFCoEInterfaces.
    5.EnsurethatFCoEEnableissettoyesonthe10GbEinitiatorportsthatyouwanttouseas
    SANbootpaths.
    6.ToenableeachinterfaceforFCoEboot,clickChangeSettings,ensurethat:
    •FCoEEnableandAUTO_VLANaresettoyes
    •DCBrequiredissettono
    •clickCreateFCoEVLANInterface
    TheVLANdialogboxappears.
    7.ClickYestoconfirmtriggeringautomaticFIPVLANdiscovery.Ifsuccessful,VLANisdisplayed
    underFCoEVLANInterface.Ifnotvisible,SANconnectivityandswitchconfigurationmust
    tobeverified.
    NOTE:IncaseofSLES11SP3inHPEFlexFabricenvironment,youmightnotseeany
    VLANwithinterfacename,whichisacceptableforthisenvironment.
    8.Whenconfigurationofalltheinterfacesiscompleted,clickOKtoproceed.
    9.ClickNexttocontinueinstallation.Toactivatemultipath,YaST2promptappearsanditmust
    beansweredappropriately.ThepromptappearsonlyifmultiplepathstothesameLUNare
    configured.
    10.Continuewiththeinstallation.
    16Installingtheoperatingsystem  
    						
    							11.UndertheExperttabontheInstallationSettingsscreen,selectBooting.
    12.SelectBootLoaderInstallationtabandthenselectBootLoaderInstallationDetails.
    Ensuretohaveonebootloaderentryanddeleteallredundantentries.
    13.ClickOKandcompletetheinstallation.
    Windows
    MicrosoftWindowsServer2008/2008R2,2012/2012R2
    MicrosoftWindowsServer2008/2008R2,2012/2012R2BootfromSANinstallationrequiresthe
    useofslipstreamDVDorISOimage,introducingthelatestQlogicEthernetdrivers.
    TocreaterequiredMicrosoftWindowsServer2008/2008R2,2012/2012R2imageISOorDVD,
    refertoAppendixA“Injecting(Slipstreaming)HPEQLogicEthernet10/20GbECNAMultifunction
    DriversintoMicrosoftWindowsServer2008/2008R2/2012/2012R2ImageFiles”(page20)
    1.InsertthenewlycreatedDVDorISOforinstallingtheapplicableMicrosoftWindowsserver
    2008/2008R2,2012/2012R2version.
    2.AfterinstallingtheOS,applythelatestServicePackforProLiant(SPP)forupdatingthe
    systemdriversandagents.
    3.Installappropriatemultipathingsoftware.
    4.Reboottheserver.
    5.Toconfiguremultipath,startHBABIOSutilityandcompletetheconfigurationofthesecondary
    andtertiarybootpaths.
    6.Rebootthesystem.
    VMware
    NOTE:BootfromSANissupportedonESXi5.1U1,ESXi5.5,orlater.
    FcoEBootfromSANrequiresthelatestHewlettPackardEnterprisecustominstallimagefor
    ESXi5.1U1orESXi5.5whichincludesQlogicEthernetFCoEdrivers.
    1.BootfromtheupdatedESXiinstallationimageandselectESXiinstallerwhenprompted.
    2.Followtheinstructionsonthescreentocontinuetheinstallationprocess.
    3.Rebootthesystem.
    VMwareBestPractices
    •FollowHewlettPackardEnterpriserecommendationfromthespecificserverbootingfrom
    aSAN.
    •Enableandconfiguretheadaptercorrectly,toallowittoaccessthebootLUN.
    •EachhostmusthaveaccesstoitsownbootLUNonlyandnotothers.Usestoragesystem
    softwaretoensurethehostaccessesonlyitsdesignatedLUNs.
    •MultipathingtoabootLUNonactive-passivearraysisnotsupportedbecausemultipathing
    isnotsupportedbyBIOSandisunabletoactivateastandbypath.
    •SANconnectionsmustbemadethroughaswitchedtopologyifthearrayisnotcertifiedfor
    directconnecttopology.Ifanarrayiscertifiedfordirectconnecttopology,SANconnections
    canbemadedirectlytothearray.
    NOTE:BootfromSANissupportedforbothswitchedtopologyanddirectconnecttopology
    ifthesetopologiesarecertifiedforthespecificarray.
    •SeespecificESX/ESXi3.x,4.x,and5.xinstallationdocumentationathttp://
    pubs.vmware.com/.
    VMwareBestPractices17 
    						
    							5Supportandotherresources
    AccessingHewlettPackardEnterpriseSupport
    •Forliveassistance,gototheContactHewlettPackardEnterpriseWorldwidewebsite:
    www.hpe.com/assistance
    •Toaccessdocumentationandsupportservices,gototheHewlettPackardEnterpriseSupport
    Centerwebsite:
    www.hpe.com/support/hpesc
    Informationtocollect
    •Technicalsupportregistrationnumber(ifapplicable)
    •Productname,modelorversion,andserialnumber
    •Operatingsystemnameandversion
    •Firmwareversion
    •Errormessages
    •Product-specificreportsandlogs
    •Add-onproductsorcomponents
    •Third-partyproductsorcomponents
    Accessingupdates
    •Somesoftwareproductsprovideamechanismforaccessingsoftwareupdatesthroughthe
    productinterface.Reviewyourproductdocumentationtoidentifytherecommendedsoftware
    updatemethod.
    •Todownloadproductupdates,gotoeitherofthefollowing:
    HewlettPackardEnterpriseSupportCenterGetconnectedwithupdatespage:
    www.hpe.com/support/e-updates
    ◦
    ◦SoftwareDepotwebsite:
    www.hpe.com/support/softwaredepot
    •Toviewandupdateyourentitlements,andtolinkyourcontractsandwarrantieswithyour
    profile,gototheHewlettPackardEnterpriseSupportCenterMoreInformationonAccess
    toSupportMaterialspage:
    www.hpe.com/support/AccessToSupportMaterials
    IMPORTANT:Accesstosomeupdatesmightrequireproductentitlementwhenaccessed
    throughtheHewlettPackardEnterpriseSupportCenter.YoumusthaveanHPPassport
    setupwithrelevantentitlements.
    18Supportandotherresources  
    						
    							Websites
    LinkWebsite
    www.hpe.com/info/enterprise/docsHewlettPackardEnterpriseInformationLibrary
    www.hpe.com/support/hpescHewlettPackardEnterpriseSupportCenter
    www.hpe.com/assistanceContactHewlettPackardEnterpriseWorldwide
    www.hpe.com/support/e-updatesSubscriptionService/SupportAlerts
    www.hpe.com/support/softwaredepotSoftwareDepot
    www.hpe.com/support/selfrepairCustomerSelfRepair
    www.hpe.com/info/insightremotesupport/docsInsightRemoteSupport
    www.hpe.com/info/hpux-serviceguard-docsServiceguardSolutionsforHP-UX
    www.hpe.com/storage/spockSinglePointofConnectivityKnowledge(SPOCK)nlStoragecompatibilitymatrix
    www.hpe.com/storage/whitepapersStoragewhitepapersandanalystreports
    Customerselfrepair
    HewlettPackardEnterprisecustomerselfrepair(CSR)programsallowyoutorepairyourproduct.
    IfaCSRpartneedstobereplaced,itwillbeshippeddirectlytoyousothatyoucaninstallitat
    yourconvenience.SomepartsdonotqualifyforCSR.YourHewlettPackardEnterpriseauthorized
    serviceproviderwilldeterminewhetherarepaircanbeaccomplishedbyCSR.
    FormoreinformationaboutCSR,contactyourlocalserviceproviderorgototheCSRwebsite:
    www.hpe.com/support/selfrepair
    Remotesupport
    Remotesupportisavailablewithsupporteddevicesaspartofyourwarrantyorcontractualsupport
    agreement.Itprovidesintelligenteventdiagnosis,andautomatic,securesubmissionofhardware
    eventnotificationstoHewlettPackardEnterprise,whichwillinitiateafastandaccurateresolution
    basedonyourproduct’sservicelevel.HewlettPackardEnterprisestronglyrecommendsthat
    youregisteryourdeviceforremotesupport.
    Formoreinformationanddevicesupportdetails,gotothefollowingwebsite:
    www.hpe.com/info/insightremotesupport/docs
    Documentationfeedback
    HewlettPackardEnterpriseiscommittedtoprovidingdocumentationthatmeetsyourneeds.To
    helpusimprovethedocumentation,sendanyerrors,suggestions,orcommentstoDocumentation
    Feedback([email protected]).Whensubmittingyourfeedback,includethedocument
    title,partnumber,edition,andpublicationdatelocatedonthefrontcoverofthedocument.For
    onlinehelpcontent,includetheproductname,productversion,helpedition,andpublicationdate
    locatedonthelegalnoticespage.
    Websites19 
    						
    							AInjecting(Slipstreaming)HPEQLogicEthernet10/20
    GbECNAMultifunctionDriversintoMicrosoftWindows
    Server2008/2008R2/2012/2012R2ImageFiles
    ToobtainthecorrectversionofHPEQLogicEthernet10/20GbECNAMultifunctionWindows
    driver,refertothelatestdriverpackagefromthereleaseCDorsearchforyouradapteron
    HPE.comandselectthepackagefortheappropriateoperatingsystemversion.
    ToinjectthedriversintotheWindowsimagefile:
    1.CreateaworkingdirectoryonthelocalmachinethatyouwillbeusingtobuildtheWindows
    Slipstreamisofile.
    2.Extractdriverpackagetotheworkingdirectory.Refertothesection“ExtractingDriver
    Packages”(page20)fordetails.
    3.Copytheslipstream.txt(InAdobeReaderorAcrobat,selectView→Show/Hide→
    NavigationPanes→Attachments)fileintotheworkingdirectory.
    4.Renametheslipstream.txtfiletoslipstream.bat.
    5.DownloadtheWindowsAssessmentandDeploymentKit(ADK)v8.1fromhttp://
    www.microsoft.com/en-in/download/details.aspx?id=39982.
    6.InstalltheWindowsADKonasupportedcomputer.
    ItisrecommendedtousethedefaultinstallationfolderforinstallingtheADK.
    7.Openacommandprompt(withadministratorprivileges)andnavigatetothefoldercontaining
    thescriptfileslipstream.bat.
    8.Executethescriptfilewiththefollowingcommand:nlslipstream.bat
    where
    pointstotherootdrivewheretheOSinstallationmediais
    available/mounted.
    pointstothesub-folder(undertheextractedfolderinstep1)containingtheplatform
    specificdrivers.
    NOTE:OSinstallationmediaisexpectedtobeavailableasalocaldrive.Networkpaths
    forOSinstallationmediaarenotsupported.
    ForExample:slipstream.batH“C:\Temp”
    NOTE:ThescriptinjectsthedrivercomponentsinalltheSKUsthataresupportedbythe
    OSinstallationmedia.
    9.Afterthescriptcompletesexecution,the.isofileisgeneratedandlocatedinthecurrent
    folder(fromwherethescriptwasexecuted).
    10.Burnthe.isofiletoaDVDusinganyDVD-creationsoftware.
    11.InstalltheapplicableWindowsServerOSversionusingthenewDVDor.isocreated.
    ExtractingDriverPackages
    1.Double-clickontheHPESPPcontainingtherelevantdrivers.
    2.ClickontheExtractbutton.
    20Injecting(Slipstreaming)HPEQLogicEthernet10/20GbECNAMultifunctionDriversintoMicrosoftWindowsServer2008/2008R2/2012/2012R2ImageFiles 
    						
    All HP manuals Comments (0)

    Related Manuals for HPe Boot From San Configuration Guide