Page 81
HP Omnibook XE4100/XE4500 Troubleshooting and Diagnostics 3-17 Diagnostic Tools This section describes the following diagnostic tools you can use for troubleshooting and repairing the notebook: • Notebook e-Diagtools diagnostic program (below). • Power-on self-test (page 3-19). • Sycard PCCtest 450 PC card (page 3-25). • Windows Management Instrumentation (page 3-26). • BIOS Setup utility (page 3-27). e-Diagtools Diagnostic Program The hardware diagnostic programs provide two levels of testing: •...
Page 82
3-18 Troubleshooting and Diagnostics HP Omnibook XE4100/XE4500 Running e-Diagtools The following procedure describes how to run e-Diagtools. The individual steps might differ slightly for different versions of e-Diagtools. 1. Click Start, Turn Off Computer (or Shut Down), Restart. 2. When the HP logo appears, press F10 to start the diagnostic test. The first time you run the program, you are prompted to select the language for the program. 3. When the menu appears, press F2 to run e-Diagtools. 4....
Page 83
HP Omnibook XE4100/XE4500 Troubleshooting and Diagnostics 3-19 Interpreting the Results The e-Diagtools diagnostic program returns test groups, error codes, and suggestions for repair and/or follow-up actions. The basic hardware test shows a recommended replacement part. To help interpret the results of the e-Diagtools tests, refer to the following: • e-Diagtools Support Ticket on page 3-18. • Replaceable Module Diagram on page 1-14 • Functional Structure Description on page 1-15 This combined...
Page 84
3-20 Troubleshooting and Diagnostics HP Omnibook XE4100/XE4500 Power-On Self-Test Note If Quiet Boot is enabled in BIOS Setup (the default setting), press Esc during boot to see POST messages. When the notebook boots, its system BIOS runs a series of initialization routines and diagnostic tests called POST (Power-On Self-Test). The BIOS will not boot the notebook’s operating system if the system memory, CPU, DMA, or interrupt controller fails the POST diagnostic tests. POST indicates progress by a...
Page 85
HP Omnibook XE4100/XE4500 Troubleshooting and Diagnostics 3-21 Beep Codes*POST Description1-3-1-3 Test 8742 Keyboard Controller (on motherboard).1-3-2-1 Set ES segment register to 4 GB.1-3-3-1 Auto size DRAM; or wrong type or no RAM installed.1-3-3-2 Initialize POST Memory Manager.1-3-3-3 Clear 512 kB base RAM.1-3-4-1 RAM failure on address line xxxx.1-3-4-3 RAM failure on data bits xxxx of low byte of memory bus.1-3-4-4 Enable cache before system BIOS shadow.1-4-1-1 RAM failure on data bits xxxx of high...
Page 86
3-22 Troubleshooting and Diagnostics HP Omnibook XE4100/XE4500 Beep Codes*POST Description3-2-1-4 Build MPTABLE for multi-processor boards.3-2-2-2 Install CD-ROM for boot.3-2-2-3 Clear huge ES segment register.3-2-2-4 Fix up Multi Processor table.3-2-3-2 Check for SMART Drive (optional).3-2-3-3 Shadow option ROMs.3-2-4-1 Set up Power Management.3-2-4-2 Initialize security engine (optional).3-2-4-3 Enable hardware interrupts.3-2-4-4 Determine number of ATA and SCSI drives.3-3-1-1 Set time of day.3-3-1-3...
Page 87
HP Omnibook XE4100/XE4500 Troubleshooting and Diagnostics 3-23 The following table lists POST messages and explanations for reported problems. If the system fails after you make changes in BIOS Setup, reset the notebook, enter BIOS Setup, and install the defaults or correct the error. Table 3-5. POST Messages MessageDescription 0200 Failure Fixed Disk Fixed (hard) disk is not working or not configured properly. Make sure the hard disk is installed properly. Run BIOS Setup and make sure the hard disk...
Page 88
3-24 Troubleshooting and Diagnostics HP Omnibook XE4100/XE4500 MessageDescription 02F4: EISA CMOS not writeable ServerBIOS2 test error: Cannot write to EISA CMOS. 02F5: DMA Test Failed ServerBIOS2 test error: Cannot write to extended Direct Memory Access (DMA) registers. 02F6: Software NMI Failed ServerBIOS2 test error: Cannot generate software Non-Maskable Interrupt (NMI). 02F7: Fail-Safe Timer NMI Failed ServerBIOS2 test error: Fail-safe timer takes too long. device Address Conflict Address conflict...
Page 89
HP Omnibook XE4100/XE4500 Troubleshooting and Diagnostics 3-25 System BIOS shadowed System BIOS copied to shadow RAM. UMB upper limit segment address: nnnn Displays the address nnnn of the upper limit of Upper Memory Blocks (UMB), indicating released segments of the BIOS that can be reclaimed by a virtual memory manager. Video BIOS shadowed Video BIOS copied to shadow RAM. Sycard PCCtest 450/460 PC Card (Optional) The PCCtest 450 and 460 cards (version 1.05) from Sycard Technology are the only...
Page 90
3-26 Troubleshooting and Diagnostics HP Omnibook XE4100/XE4500 Windows Management Instrumentation (WMI) The Windows Management Instrumentation is basically sets of rules for accessing information about a notebook. WMI allows an application to determine, for example, the operating system being used, which hardware and software components are in the notebook, and possibly whether any of the components need replacing. A local or remote application can use the WMI interface to check which hardware and...