HP 5500 Ei 5500 Si Switch Series Configuration Guide
Here you can view all the pages of manual HP 5500 Ei 5500 Si Switch Series Configuration Guide. The HP manuals for Printer are available online for free. You can easily download all the documents as PDF.
Page 2071
8 A second in which errored frames appear is called an errored frame second. Remote fault detection Information OAMPDUs are exchanged periodically among Ethernet OAM entities across established OAM connections. In a network where traffic is interrupted due to device failures or unavailability, the flag field defined in information OAMPDUs allows an Ethernet OAM entity to send error information—the critical link event type—to its peer. You can use the log information to track ongoing link status...
Page 2072
9 Task Remarks Configuring errored frame period event detection Optional Configuring errored frame seconds event detection Optional Configuring Ethernet OAM remote loopback Enabling Ethernet OAM remote loopback Optional Rejecting the Ethernet OAM remote loopback request from a remote port Optional Configuring basic Ethernet OAM functions For Ethernet OAM connection establishment, an Ethern et OAM entity operates in active mode or passive mode. Only an Ethernet OAM entity in active mode ca...
Page 2073
10 Step Command Remarks 1. Enter system view. system-view N/A 2. Configure the Ethernet OAM handshake packet transmission interval. oam timer hello interval Optional. 1000 millisecond by default. 3. Configure the Ethernet OAM connection timeout timer. oam timer keepalive interval Optional. 5000 milliseconds by default. Configuring link monitoring After Ethernet OAM connections are established, the link monitoring periods and thresholds configured in this section take effect on...
Page 2074
11 Configuring errored frame seconds event detection IMPORTANT: Make sure the errored frame seconds tri ggering threshold is less than the errored frame seconds detection interval. Otherwise, no errored fram e seconds event can be generated. To configure errored frame seconds event detection: Step Command Remarks 1. Enter system view. system-view N/A 2. Configure the errored frame seconds event detection interval. oam errored-frame-seconds period period-value Optional. 60...
Page 2075
12 service loopback groups. For more information about link aggregation groups and service loopback groups, see Layer 2—LAN Switching Configuration Guide . • Enabling internal loopback test on a port in remote loopback test can terminate the remote loopback test. For more information about loopback test, see Layer 2—LAN Switching Configuration Guide . Configuration procedure To enable Ethernet OAM remote loopback in user view: Task Command Remarks Enable Ethernet OAM remote loopback on a...
Page 2076
13 Displaying and maintaining Ethernet OAM configuration Task Command Remarks Display global Ethernet OAM configuration. display oam configuration [ | { begin | exclude | include } regular-expression ] Available in any view Display the statistics on critical events after an Ethernet OAM connection is established. display oam critical-event [ interface interface-type interface-number ] [ | { begin | exclude | include } regular-expression ] Available in any view Display...
Page 2077
14 [DeviceA-GigabitEthernet1/0/1] oam mode passive [DeviceA-GigabitEthernet1/0/1] oam enable [DeviceA-GigabitEthernet1/0/1] quit # Set the errored frame detection interval to 20 seconds and set the errored frame event triggering threshold to 10. [DeviceA] oam errored-frame period 20 [DeviceA] oam errored-frame threshold 10 2. Configure Device B: # Configure GigabitEthernet 1/0/1 to operate in active Ethernet OAM mode (the default) and enable Ethernet OAM for it. system-view [DeviceB]...
Page 2078
15 The output shows that no critical link event occurred on the link between Device A and Device B. You can use the display oam link-event command to display the statistics of Ethernet OAM link error events. For example: # Display Ethernet OAM link event statistics of the remote end of Device B. [DeviceB] display oam link-event remote Port :GigabitEthernet1/0/1 Link Status :Up OAMRemoteErrFrameEvent : (ms = milliseconds) ---------------------------------------------------------------------...
Page 2079
16 Configuring CFD CFD overview Connectivity Fault Detection (CFD), which conforms to IEEE 802.1ag Connectivity Fault Management (CFM) and ITU-T Y.1731, is an end-to-end per-VLAN link layer Operations, Administration and Maintenance (OAM) mechanism used for link connectivity detection, fault verification, and fault location. Basic concepts in CFD Maintenance domain A maintenance domain (MD) defines the network where CFD plays its role. The MD boundary is defined by some maintenance association...
Page 2080
17 An MA serves a VLAN. Packets sent by the MPs in an MA carry the relevant VLAN tag. An MP can receive packets sent by other MPs in the same MA. Maintenance point An MP is configured on a port and belongs to an MA. MPs fall into two types: maintenance association end points (MEPs) and maintenance association intermediate points (MIPs). • MEP E a c h M E P i s i d e n t i f i e d b y a n i n t e g e r c a l l e d a M E P I D . T h e M E P s o f a n M D d e f i n e t h e r a n...