    Have a look at the manual Honeywell thermostat ST9400A 1 Day 2 Channel Programmer User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 178 Honeywell manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							
    11
    
    OPERATING YOUR ST900A
    Overriding the Operation Without Changing the Programmes
    In AUTO and ONCE operating modes, the OVERRIDE buttons switch the heating or hot water ON or OFF without altering the programme. 
    When the indicator lamp is ON, pressing the OVERRIDE button switches the heating or hot water OFF until the next programmed ON time.
    When  the  indicator  lamp  is OFF,  pressing  the OVERRIDE  button  switches  the heating or hot water ON until the next programmed OFF time.
    The LoT™ Display will provide you with information about the override.
    The Extra Hour Function (for Heating and/or Hot Water)
    The EXTRA HOUR buttons allow you to switch the heating or hot water ON for up to 3  extra  hours  without  altering  the  programme.  Pressing  either  button  once  will  give one extra hour.  The LoT™ Display will display the message ‘+ 1 HOUR’, to confirm the button has been pressed. 
    When  the  green INDICATOR  LAMP  is OFF,  pressing  an EXTRA  HOUR  button switches the heating or hot water ON for just one hour.
    When  the  green INDICATOR  LAMP  is ON,  pressing  an EXTRA  HOUR  button extends the programmed ON period by one hour.
    Further presses of the EXTRA HOUR buttons will increase the extra hour period by one hour for each button press, up to a maximum of 3 hours.  The LoT™ Display will continue to provide information on the extra hour status.
    To  cancel  the  extra  hours,  just  keep  pressing  the EXTRA  HOUR  button  until  the ‘CANCELLED’ message appears on the LoT™ Display. 
    						
    							
    12
    
    FINE TUNING YOUR ST900A
    Changing from AM/PM Time Display to the 2 Hour Clock
    Your  ST9400A  can  operate  on  the  12  hour  AM/PM  or  24  hour  clock  formats.  To change the format, ensure the slider is in the RUN position then press and hold the   and  buttons together for about 2 seconds. Ignore the ‘NOT VALID’ message that will appear briefly. All the displayed times will be automatically changed to the new format.
    Repeating this procedure will change the clock display back to the original format.
    Changing the Installer Parameters
    The  ST9400A  has  a  special  Installer  Mode  where  some  features  can  be  adjusted to suit your lifestyle or preferences – these are called Installer Parameters, and are listed in the table below, along with a description of the options that are possible.
    INSTALLER PARAMETERParameter NumberDefault ValueOptionsDescription
    24hr or am/pm clock display.11212, 2412 = am/pm display,24 = 24hr display
    Configure backlight operation.220, 1, 20 = off, 1 = on if button pressed,2 = on continuously
    Enable/disable auto time change.310, 10 = disabled, 1 = enabled
    Number of ON/OFFs per day.522, 32 = 2 on/offs per day,3 = 3 on/offs per day
    Select default time programme.6AA, b, CA = standard, b = at home,C = economy
    Configure Mini-Programmer.
    This will be set by your Installer and will depend on your system – do NOT change without contacting installer.
    700,10 = standard Programmer,1 = Mini-Programmer
    Reset all parameters810, 10 = do not reset1 = default parameters 
    						
    							
    1
    
    FINE TUNING YOUR ST900A
    To Enter Installer Mode:
    a. Ensure the slider is in the RUN position, then press and hold  and  buttons together for 8 seconds. Ignore the ‘NOT VALID’ message that is displayed for a few  seconds.  The  message  ‘SET  UP  MENU’  will  show  briefly,  followed  by  ‘SET INSTALLER OK ?’
    b. Press the  button to take you into the Installer Mode Parameter Menu.
    c.  Parameter  1  is  now  available  to  change.  This  is  to  allow  you  to  change  the clock  format  from  12  hour  AM/PM  to  24  hour.  At  every  step,  the  LoT™  Display will  inform  you  what  the  parameter  means  and  what  option  you  have  selected. The  parameter  number  is  shown  on  the  display  separated  by  a  colon  from  the parameter value.
    d. You can change the parameter value by pressing the   or  buttons. At this point  the  description  in  the  LoT™  Display  will  change  and  the  parameter  value will flash. If you press  the value will stop flashing and be saved for use.
    e.  Press  to move to the next parameter available for editing.
    f.  Keep  pressing   to  step  around  the  list  of  parameters,  and  use    or  buttons to change the parameter value.
    g. Any  parameter  changes  that  have  been  confirmed  with  the   button  will  be saved and used.
    To Exit Installer Mode:
    h. You can exit Installer Mode at any time by moving the slider to the next position and then back again to RUN.
     Note:  Installer  Mode  will  exit  automatically  after  10  minutes  if  the  slider  is  not moved. 
    						
    							
    1
    
    FAQ AND TROUBLESHOOTING
    How  do  I  set  the  time  only,  if  the  ST900A  clock  is  not correct?
    Your ST9400A contains a very accurate digital clock that is factory pre-set. Should you ever need to change the time, just follow this procedure:
    a. Move the slider to the DAY/TIME position.
    b. Keep  pressing  the  green   button  until  the  message  ‘SET  THE  TIME’  is displayed.  To  change  the  time,  press  the    or   buttons  until  the  correct time is shown. The message ‘IS TIME OK?’ will be displayed. Press the green  button to confirm the time is correct.  If you have made a change, the message ‘TIME SAVED’ will show, followed quickly by ‘DATE + TIME COMPLETE’.
    c.  Move the slider to the RUN position, to complete changing the time.
    What do I do when the clocks go back in October and forward in March?
    Your  ST9400A  is  factory-set  to  adjust  the  clock  automatically  at  the  correct  dates, so  you  should  never  need  to  adjust  the  clock  forward  or  backwards  yourself.  It  is possible to disable this particular feature, as described in the section ‘Changing the Installer Parameters’ (page 12). You may also check the section ‘Configuration & Service Data’ (page 18) to see how your Installer has configured your product.
    What  should  I  do  if  I  get  ‘lost’  while  programming  the ST900A?
    The  LoT™  Display  on  ST9400A  will  provide  you  with  help  and  tips  to  work  through the programming. Should you ever get ‘lost’, the simplest thing to do is to move the slider  to  the RUN  position,  and  then  move  it  back  to  the  appropriate  programming position where you got lost. At this point just follow the instructions again.
    What happens if there is a power failure?
    In  the  event  of  a  mains  power  failure,  the  ST9400A  display  will  go  blank,  the indicator lamps will go out, and the control outputs will switch off. The real time will be  constantly  maintained  by  means  of  the  built-in  battery  backup,  ready  to  power back up as if nothing had happened when the mains power is restored. In addition, all  programmes  and  settings  are  stored  in  a  special  memory  (called  NV  memory) which requires no power to maintain information, and so will be retained indefinitely.
    Should the correct time and date ever be lost, for whatever reason, the message ‘SET DATE + TIME’ will be displayed whilst the slider is in the RUN position. In this case, simply  follow  the  procedure  described  under  ‘Step  1:  Setting  the  Date  &  Time’ (page 4). It should not be necessary to make any changes to your programmes. 
    						
    							
    1
    
    SymptomPossible CauseRemedy
    ST9400A has a blank LCD displayNo power to the heating systemCheck that there is power to the heating system
    Fault in ST9400ACall Installer
    ST9400A indicates that Heating and/or Hot Water are ON, but radiators are cold and/or taps are running with cold water.
    Temperature controls are switched off or set too low
    Check that the temperature controls in the system are set to appropriate levels
    Boiler or other system controls have malfunctioned
    Call Installer
    ST9400A shows the message ‘INTERNAL FAULT’
    Fault in ST9400ACall Installer
    When the slider is moved to the HOT WATER position, the display shows ‘NOT VALID’
    ST9400A has been configured as a Mini-Programmer
    Check the Contents page of this booklet or the ‘Configuration & Service Data’ section (page 18) to see if your ST9400A has been configured as a Mini-Programmer.
    Call Installer to check if this is correct for your heating system.
    Troubleshooting Guide
    This  is  a  quick  guide  to  help  you  diagnose  and  cope  with  possible  problems  with ST9400A. For further assistance, please contact your Installer.
    FAQ AND TROUBLESHOOTING 
    						
    							
    1
    
    MINI-PROGRAMMER OPERATING INSTRUCTIONS
    You need only refer to this section if:
    • The Mini-Programmer box is ticked on the Contents page of this booklet, or
    • The  ST9400A  Configuration  Data  (page  18)  indicates  it  is  set  as  a  Mini-Programmer.
    What is a Mini-Programmer?
    In  a  poorly  controlled  gravity  circulation  hot  water  system,  whenever  the  boiler comes on to service the heating, there will inevitably be some circulation though the hot water storage tank, which will then heat up.
    So, whenever the HEATING is ON, the HOT WATER is also ON.
    It  is  therefore  NOT  possible  to  have  independent  programmes  for  heating  and  hot water, so it is only necessary to enter one time programme.
    If you have this type of installation (gravity circulation hot water circuit WITHOUT a hot water control valve), your Installer should have restricted the ST9400A Programmer to be a Mini-Programmer.
    This section describes how to use the product as a Mini-Programmer.
    Modifying the Heating & Hot Water Programme
    The heating & hot water programme has three pairs of ON/OFF switching times per day. Each time can be set between 3.00 am and 2.50 am (on the next day) to allow you to programme the heating & hot water to stay on past midnight, if required. 
    a. Move  the  slider  to  the HEATING  position.  ‘SET  HEATING’  will  show  briefly  to verify this action.
    b. Now follow the same procedure to set the times as described in ‘Modifying the Hot Water Programme’ (page 7) steps b to e.
    Exiting Heating & Hot Water Programming Mode:
    To exit HEATING Programming mode, move the slider to the RUN position. This can be done at any time during the programming process, and any changes made and confirmed with the  button will have been saved.
    Note:  If  the  unit  is  left  in HEATING  Programming  mode  for  more  than  10  minutes without the slider being moved or any buttons pressed, the message ‘MOVE SLIDER’ will  be  displayed.    Press  a  button  to  finish  programming,  or  move  the  slider  to  the RUN position. 
    						
    							
    1
    
    Disabling / Enabling Time Periods
    To disable any of the time periods ON 1 to OFF 1 or ON 2 to OFF 2, simply set the ON  time  and  its  paired OFF  time  to  the  same  time,  and  the  programme  will  just ignore them.
    To re-enable the time period, simply set the two ON and OFF times to be different.
    Choosing the Operating Mode 
    In  a  Mini-Programmer,  some  Operating  Modes  are  not  possible.  For  example, HEATING  in AUTO  mode  and HOT  WATER  in OFF  mode  is  not  allowed.  When configured,  your  ST9400A  knows  which  combinations  of  Operating  Mode  are possible, and only permits those combinations that are allowed.
    Override and Extra Hour Functions
    When  you  use  the  hot  water OVERRIDE  or EXTRA  HOUR  functions,  they  will operate as normal. However, the heating OVERRIDE or EXTRA HOUR functions will also bring on the hot water. This is a consequence of the type of system you have, and is perfectly normal.
    Other Functions
    All other functions operate the in the same way as for the standard ST9400A.
    MINI-PROGRAMMER OPERATING INSTRUCTIONS 
    						
    							
    150022737-004 A
    CONFIGURATION & SERVICE DATA
    Configurable FeaturesOptionsInstaller Configured (tick appropriate box)
    24hr or am/pm clock displayam/pm display
    24hr display
    Display backlight operationOff
    On if button pressed
    On continuously
    Automatic time changeEnabled
    Disabled
    Number of ON/OFFs per day2 on/offs per day
    3 on/offs per day
    Default programmeA = standard
    b = at home
    C = economy
    Set as Mini-Programmer *No
    Yes
    Configuration Data (to be completed by Installer)
    The  table  below  is  for  the  Installer  to  complete  to  indicate  how  your  ST9400A  has been configured.
    * Note:  It  is  recommended  that  gravity  circulation  hot  water  systems are  fitted  with  a  suitable  hot  water  control  valve  as  shown  in  the Honeywell  Sundial  C  Plan  system  (see  ST9400A/ST9400C  Installation Instruction  sheet).  If  so,  then  there  is  no  need  to  set  the  ST9400A  as  a Mini-Programmer. 
    						