Have a look at the manual Honeywell thermostat CM921 1 Day Wireless Programmable Thermostat User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 178 Honeywell manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
11 fINE TuNING THE CM921 c. Now choose which one of the following parameters you would like to chang\ e: i) Change the time format ‘CLOCK SELECT’ should be displayed on the screen - press the or buttons to select the preferred time format (12=AM/PM format, 24=24hr format) and the display will flash, indicating a change has been made. To confirm this change press the green button. ii) Reset the built-in program to the factory default Press the time button once. The display will show ‘RESET PROGRAM’. Press the or buttons to select the preferred setting (0=user program, 1=factory program) and the display will flash, indicating a change has been made. To confirm this change press the green button. iii) Enable or disable summer/winter time change Press the time button twice. The display will show ‘AUTO CHANGE’. Press the or buttons to select the preferred setting (0=disabled/Off, 1=enabled/On) and the display will flash, indicating a change has been made. To confirm this change press the green button. d. To exit the user mode move the slider switch to the AUTO, MAN or OFF position.
12 Symptom Possible Cause Remedy The thermostat has a blank LCD screen. Batteries not installed. Check to see if there are batteries in the battery compartment and the paper tab has been removed. Incorrect battery orientation. Check that the batteries have been installed in the correctorientation. Exhausted batteries. Replace with new batteries. The thermostat shows a flashing symbol on the LCD screen. Batteries are exhausted and need replacing. Replace with new batteries. The thermostat’s LCD display shows a symbol but the heating does not switch on. The heating is not required at this moment. The heat demand is send to the BDR91 as a value between 0-100%. The BDR91 will adjust the boiler on time to meet this requirement. That is why the heating will be off sometimes even if the symbol is displayed. To check if RF system is communicating properly press the button to increase the set temperature a few degrees above the current temperature. The heating should come on after a few seconds. The thermostat shows a flashing symbol on the LCD screen. Fault in thermostat Remove and re-insert the batteries in the thermostat. If the symbol does not clear itself in a few minutes call the installer. Troubleshooting Guide fA q’s & TR oublESHoo TING
13 fA q’s & TR oublESHoo TING Symptom Possible Cause Remedy The thermostat’s LCD display works but the heating does not switch on (BDR91 LEDs are off or green one is on). No power to heating system. Check that there is power to the heating system. Program does not call for heat. Move the slider switch to MAN and press or to increase the temperature a few degrees above the current room temperature. The heating should come on after a few seconds. Wrong electrical connection. Call electrical installer to check the boiler and BDR91 power supply as well as the connection between the boiler and the BDR91. The red LED on the BDR91 is constantly on or flashing. RF communication lost due to the wrong location of the thermostat. Hook the thermostat back on the wall bracket or replace the thermostat on the table stand in the position where RF communication was reliable. RF communication fault. Call installer.NOTE: You can control the boiler manually when the RF communication is lost: Press the BDR91 push button to switch the boiler on and off. When the green LED is on – the boiler is on. Heating switches ON or OFF too slowly or quickly. The thermostat not set correctly for your system. Call Installer. Temperature swings between too hot and too cold. The thermostat not set correctly for your system. Call Installer.
14 How do I change the batteries on the CM921 when they run out? The thermostat constantly monitors the battery power level, which typically last for about 2 years before needing replaced. When the power is running low a flashing symbol will be displayed on the screen. To change the batteries follow the steps in the above section (‘STEP 1: Installing the Batteries’ on page 3), replacing the used batteries with new ones in step c. Note: While changing the batteries your program settings will be stored but you may need to adjust the time and date settings to be correct. How do I set one temperature for the whole day? To operate as a simple thermostat with one temperature for a period of time, move the slider switch to the MAN position. Adjust the manual temperature by pressing the or buttons. This can be set anywhere from 5°C to 35°C in 0.5°C steps. The thermostat will continue to maintain this temperature until another operating mode is selected or the temperature is adjusted. What is Optimum Start? Optimum Start is a program which ensures that the optimum temperature conditions are achieved at the required times. This is an Energy Efficiency feature that adjusts the start time of your heating system depending upon how cold it is. For example, on cold days your heating system will be started earlier to ensure that your home is warm when you get up (at the target temperature) and on warmer days the heating system will be started later to save energy. So, if the Optimum Start Feature is used, then the time / temperature settings which are entered into the thermostat should be set to when you want to be warm by and not when you want the heating system to start. I want to use the table stand instead of wall mounted bracket. Where can I position the room unit? It is important to keep the room unit in a location where reliable RF communication was proven. Advise your installer where would you like to position the room unit and he will check if the RF communication is reliable in the selected location(s). Important: The Room Unit measures the temperature of the room where it is located. It is important that the placement of the Room Unit within the room is away from; draughts, direct sunlight and other heat sources. As this is a wireless device certain objects could interfere with the RF signal - Leave at least 30cm distance from any metal objects (including wall boxes) and at least 1 metre from any other electrical equipment eg. radio, TV, PC, etc. fA q’s & TR oublESHoo TING
15 How do I remove the thermostat from the table stand or wall bracket? After programming is finished always replace the thermostat back on the wall holder or table stand. BDR91 Relay Box Controls Layout What does it mean when the BDR91 relay box green LED is ON? Green LED indicates normal operation of the radio frequency system. When the green LED is ON the boiler is also ON. When the LED is OFF the boiler is O\ FF. fA q’s & TR oublESHoo TING Wall bracketTable stand Push button and relay status LED’s
16 Can I use my CM921 to control my air-conditioning system? Yes, if your system has been set up correctly you can use your thermostat to control the cooling. To switch the thermostat between heating and cooling modes press the and buttons together for 5 seconds in any of the product operating modes (AUTO, MAN or OFF). The text ‘COOLING’ will be displayed for a moment on the screen to indicate the cooling operation is now active. The factory default program for cooling is specified in the table below, but this can be modified in the same way as the default heating program: period 1 2 3 4 5 6 Time 6:30 8:00 12:00 14:00 18:00 22:30 Temperature 24°C 28°C 24°C 28°C 24°C 24°C fA q’s & TR oublESHoo TING How do I operate an HR 80 radiator controller with my CM921? 1. Display: Shows current set temperature and device information. 2. Adjustment dial on the operating unit: Allows manual temperature adjustment. 3. Symbol for the RF connection to the command centre. 4. Symbol for separating the operating unit and coupling module. 5. Set temperature. 6. Symbol for actual value coming from the room thermostat (see installation manual 4.5.2). Changing the set temperature with adjustment dial The setpoint is normally defined and controlled at the room thermostat. To override the local setpoint, turn the adjustment dial of the radiator controller unit until the desired set temperature (between 5 - 30 °C) is displayed. This local setpoint override remains valid until a time program from the room thermostats overwrites it automatically. In order to open or close the radiator valve completely turn the adjustment dial until “OFF” (closed) or “ON” (opened) is displayed. (If temperature limits are set, “ON”/”OFF” is not displayed - see installation manual 4.5.1)\ . 1 2 3456