    Have a look at the manual Honeywell thermostat CM907 7 Day Programmable Thermostat User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 178 Honeywell manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							1011
    OPERATING THE CM907
    • DAY OFF FUNCTION
     The day off function allows you to temporarily run Sunday’s heating program for as many days as you desire. This is useful when you have a day off during your normal  week  or  will,  unintentionally,  be  at  home  on  a  workday  due  to  illness, etc.
     To set the Day Off function:
     a. Move the slider switch to the AUTO position.
     b. Press  the   button  to  display  the  days  off  counter,  ‘DAYS  OFF’  will  be displayed and the day off indicator  will appear.
     c. Press  the    or  buttons  to  set  the  number  of  days  (1  –  99  days)  you would like the alternative heating program to run for.
       Note:  (The  day  and  date  will  update  according  to  the  number  of  days selected).
     d. Press the green  button to confirm the setting.
     e. On  confirmation  ‘CHANGES  SAVED’  will  be  displayed  on  the  screen  for  a moment and then will return to the normal display, with the days off indicator displayed.
     The  thermostat  will  now  control  to  the  alternative  heating  program  for  the  set number of days before resuming with the normal heating program. To cancel the DAY OFF mode or to exit the function at any time press the  button a second time or move the slider switch to a different position.
    Adjusting the Time
    To adjust only the time during normal operation use the   or  buttons to adjust the time and press the green  button again to confirm any changes. 
    						
    							1213
    FINE TUNING THE CM907
    Changing the User Parameters
    The user mode allows you to modify some basic settings of the thermostat to meet your personal preferences. You can change the time display format (24hr or AM/PM), reset the heating program to the built-in settings and disable or enable the summer/winter time change feature.
    To change any of these user’s parameters:
    a. Move the slider switch to the OFF position, then press and hold the  button for approximately 5 seconds. button for approximately 5 seconds.
    b. Once entered the following information will be shown on the screen:
    COPYDAY
    DAY
    1..6CM907
    DATEPROGAUTOMANOFF
    OFF  
    						
    							1213
    FINE TUNING THE CM907
    c. Now choose which one of the following parameters you would like to change:
     i) Change the time format
     ‘CLOCK  SELECT’  should  be  displayed  on  the  screen  -  press  the    or  buttons to select the preferred time format (12=AM/PM format, 24=24hr format) and  the  display  will  flash,  indicating  a  change  has  been  made.  To  confirm  this change press the green  button.
     ii) Reset the built-in program to the factory default
     Press  the    time  button  once.  The  display  will  show  ‘RESET  PROGRAM’. Press  the    or   buttons  to  select  the  preferred  setting  (0=user  program, 1=factory  program)  and  the  display  will  flash,  indicating  a  change  has  been made. To confirm this change press the green  button.
     iii) Enable or disable summer/winter time change
     Press the   time button twice. The display will show ‘AUTO CHANGE’. Press the   or  buttons to select the preferred setting (0=disabled/Off, 1=enabled/On)  and  the  display  will  flash,  indicating  a  change  has  been  made.  To  confirm this change press the green  button.
    d. To  exit  the  user  mode  move  the  slider  switch  to  the AUTO, MAN or OFF position. 
    						
    							1415
    How do I change the batteries on the CM907 when they run out?
    The  thermostat  constantly  monitors  the  battery  power  level,  which  typically  last  for about  2  years  before  needing  replaced.  When  the  power  is  running  low  a  flashing symbol will be displayed on the screen. To change the batteries follow the steps in the above section (‘STEP 1: Installing the Batteries’ on page 3), replacing the used batteries with new ones in step c.
    Note: While changing the batteries your program settings will be stored but you may need to adjust the time and date settings to be correct.
    How do I set one temperature for the whole day?
    To operate as a simple thermostat with one temperature for a period of time, move the slider switch to the MAN position. Adjust the manual temperature by pressing the    or   buttons.  This  can  be  set  anywhere  from  5°C  to  35°C  in  0.5°C  steps.  The thermostat will continue to maintain this temperature until another operating mode is selected or the temperature is adjusted.
    What is Optimum Start?
    Optimum Start is a program which ensures that the optimum temperature conditions are achieved at the required times. This is an Energy Efficiency feature that adjusts the  start  time  of  your  heating  system  depending  upon  how  cold  it  is.  For  example, on cold days your heating system will be started earlier to ensure that your home is warm when you get up (at the target temperature) and on warmer days the heating system will be started later to save energy. So, if the Optimum Start Feature is used, then  the  time  /  temperature  settings  which  are  entered  into  the  thermostat  should be set to when you want to be warm by and not when you want the heating system to start.
    FAQ’s & TROUBLESHOOTING 
    						
    							1415
    FAQ’s & TROUBLESHOOTING
    Can I use my CM907 to control my air-conditioning system?
    Yes, if your system has been set up correctly you can use your thermostat to control the  cooling.  To  switch  the  thermostat  between  heating  and  cooling  modes  press the   or  buttons together for 5 seconds in any of the product operating modes (AUTO, MAN or OFF).  The  text  ‘COOLING’  will  be  displayed  for  a  moment  on  the screen to indicate the cooling operation is now active. The factory default program for cooling is specified in the table below, but this can be modified in the same way as the default heating program:
    Monday to Friday
    Period 1 2 3 4 5 6
    Time 6:30 8:00 12:00 14:00 18:00 22:30
    Temperature 24°C 28°C 24°C 28°C 24°C 24°C
    Saturday & Sunday
    Period 1 2 3 4 5 6
    Time 8:00 10:00 12:00 14:00 18:00 23:00
    Temperature 24°C 24°C 24°C 24°C 24°C 24°C
    If something happens to my heating system how can I check that the thermostat is working?
    Refer to the Troubleshooting Guide on page 17. If you still need assistance after this call your installer. The thermostat should only be opened or removed by a qualified professional  to  prevent  possible  injury  from  electric  shock  and/or  damage  to  the product. 
    						
    							1617
    FAQ’s & TROUBLESHOOTING
    What other accessories can I buy that work with the CM907?
    1. Outside Temperature Sensor Accessory
     The  Outside  Temperature  Sensor  accessory  can  be  fitted  to  your  thermostat  to display the outside temperature. By pressing the  button twice, the thermostat displays the external temperature.
    2. Remote Temperature Sensor Accessory
     The  Remote  Temperature  Sensor  accessory  can  be  fitted  to  your  thermostat  to control  the  temperature  of  another  room  where  it  is  inconvenient  to  locate  the thermostat  e.g.  commercial  premises  where  the  public  may  tamper  with  the buttons.
    Note: For more information on the above accessories please contact your installer. 
    						
    							1617
    Troubleshooting GuideSymptomCM907 has a blank LCD screenCM907 shows a flashing 
     
    symbol on the LCD screenThe CM907’s LCD screen works but the heating does not switch onHeating switches ON or OFF too slowly or quicklyTemperature swings between too hot and too cold.CM907 shows a flashing 
     symbol on the LCD 
    screen
    Possible CauseBatteries not installedIncorrect battery orientationExhausted batteriesBatteries are exhausted and need replacingNo power to heating systemProgram does not call for heatCM907 not connected to boiler properlyCM907 not set correctly for your systemCM907 not set correctly for your systemFault in CM907
    RemedyCheck to see if there are batteries in the battery compartment and the paper tab has been removedCheck that the batteries have been installed in the correctorientationReplace with new batteriesReplace with new batteries Check that there is power to the heating system.Move the slider switch to 
    MAN 
    and press 
      or to 
    increase the temperature a few degrees above the current room temperature. The heating should come on after a few seconds.Call installer to check electrical connection between the CM907and the boiler.Call InstallerCall InstallerRemove and re-insert the batteries in the CM907. If the 
     symbol does not clear itself in a few 
    minutes call the installer 
    						
    							1842010943-703 R1
    ...an explanation for householders
    A  programmable  room  thermostat  is  both  a  programmer  and  a  room  thermostat.  A programmer allows you to set ‘On’ and  ‘Off’ time periods to suit your own lifestyle. A  room  thermostat  works  by  sensing  the  air  temperature,  switching  on  the  heating when the air temperature falls below the thermostat setting, and switching it off once this set temperature has been reached. 
    So,  a  programmable  room  thermostat  lets  you  choose  what  times  you  want  the heating to be on, and what temperature it should reach while it is on. It will allow you to select different temperatures in your home at different times of the day (and days of the week) to meet your particular needs. Turning a programmable room thermostat to a higher setting will not make the room heat  up  any  faster.  How  quickly  the  room  heats  up  depends  on  the  design  of  the heating system, for example, the size of boiler and radiators. 
    Neither  does  the  setting  affect  how  quickly  the  room  cools  down.  Turning  a programmable  room  thermostat  to  a  lower  setting  will  result  in  the  room  being controlled at a lower temperature, and saves energy.
    The  way  to  set  and  use  your  programmable  room  thermostat  is  to  find  the  lowest temperature  settings  that  you  are  comfortable  with    at  the  different  times  you  have chosen,  and  then  leave  it  alone  to  do  its  job.  The  best  way  to  do  this  is  to  set  low temperatures  first,  say  18°C,  and  then  turn  them  up  by  one  degree  each  day  until you are comfortable with the temperatures. You won’t have to adjust the thermostat further. Any adjustments above these settings will waste energy and cost you more money.
    If  your  heating  system  is  a  boiler  with  radiators,  there  will  usually  be  only  one programmable room thermostat to control the whole house. But you can have different temperatures in individual rooms by installing thermostatic radiator valves (TRVs) on individual  radiators.  If  you  don’t  have  TRVs,  you  should  choose  a  temperature  that is  reasonable  for  the  whole  house.  If  you  do  have  TRVs,  you  can  choose  a  slightly higher setting to make sure that even the coldest room is comfortable, then prevent any overheating in other rooms by adjusting the TRVs.
    WHAT IS A PROGRAMMABLE ROOM THERMOSTAT? 
    						