Have a look at the manual Honeywell thermostat CM721 1 Day Wireless Programmable Thermostat User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 178 Honeywell manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
11 PROGRAMMING THE CM727 ‘Efficient Daily Use’ f. i) Press the COPY DAY button to copy Monday’s program into Tuesday. The display will go blank apart from the ‘non flashing’ day indicator, which indicates the day copied and the ‘flashing’ target day to copy the program to. To accept this day press the green button. To select a different target day press the DATE/DAY button until the ‘flashing’ day indicator is under the required day, then accept it by pressing the green button. Note: Once the target day is confirmed it becomes the day that is copied if the COPY DAY button is pressed again. OR ii) Press the DATE/D AY button to move the day indicator to Tuesday (Day 2). The program for that day can then be adjusted by following steps b to e. Programs for the remaining days can be set in the same way, using the DATE/D AY button to move to the next day. To exit the programming mode select the desired operating mode by pressing the AUTO, MAN or OFF buttons. Note: To run the adjusted program select the AUTO mode. Disabling / Enabling Time Periods The thermostat has 4 periods each day that can be programmed, but you may not need all of these switch points for your heating requirements. Therefore, any period from 2 to 4 can be removed from (or returned to) the heating program profile. To disable or enable time periods: a. To disable unwanted periods go to the desired period (2 to 4) using the PROGRAM or buttons to navigate, ensure the correct period is highlighted with the flashing square symbol. Press and hold the button for at least 2 seconds and the display will indicate the period has been removed from the program. b. To enable periods again follow the same procedure as above, navigating to the already disabled period. To enable this period again press and hold the button for at least 2 seconds. OPERATING THE CM727 ‘Using the Features’ Choosing the Operating Mode The thermostat can operate in three different modes: Automatic, Manual or Off. To set the operating mode press either of the AUTO, MAN or OFF buttons. The screen indicates which mode is currently active by displaying AUTO, MAN or OFF. • AUTO (automatic) mode sets the thermostat to follow the built-in temperature program (default or personalised). Operating the thermostat in this mode is the best way to maintain a high level of temperature comfort whilst maximising your energy savings. • MAN (manual) mode sets the thermostat to act as a simple thermostat with a fixed setpoint throughout the day. The setpoint can be adjusted from 5°C to 35°C by using the or buttons. The thermostat will continue to maintain this temperature until another operating mode or temperature is selected. • OFF mode sets the thermostat to control to a minimum temperature setting of 5°C (default) that acts as a frost protection measure for your home.
12 During Normal Operation • Temperature Enquiry In AUTO, MAN and OFF operating modes the thermostat will display the current room temperature. To review the programmed ‘target’ temperature (the temperature which the thermostat is trying to maintain) press the button. This ‘target’ temperature value will be displayed flashing for 5 seconds before returning to the current room temperature value. • Temperature Override During normal operation (AUTO mode) the programmed temperature can be adjusted manually by pressing the or buttons or the button. The ‘target’ temperature will be displayed and flash for 5 seconds - during this time the or buttons can be used to modify the set value. Note: This temperature override is cancelled at the next programmed temperature change. Adjusting the Time To adjust only the time during normal operation use the or buttons to adjust the time and press the green button again to confirm any changes. Using the Special Functions • HOLIDAY Function The holiday function allows you to set a constant temperature (default = 10°C) for a specified number of days (from 1 - 99 days). This lets you save energy and related costs when you are away from home, but resumes normal operation on the day of your return. To set the Holiday function: a. Ensure the thermostat is running in AUTO or MAN operating modes. b. Press the holiday button to display the holiday days counter and temperature setting, along with the holiday indicator . c. Press the or time buttons to set the holiday time (1 - 99 days) and press the green button to confirm. d. Press the or buttons to set the holiday temperature (5°C - 35°C) and press the green button to confirm. The thermostat will now control to the new temperature for the set number of days that your home is vacant. At midnight the holiday counter will be reduced by one until the selected number of days have passed. The thermostat will then return to normal operation as set by the MAN or AUTO mode. To cancel the HOLIDAY function or to exit the function at any time press the button a second time. ‘Using the Features’ OPERATING THE CM727
13 Using the Special Features • SERVICE indicator (optional) Note: This option only works if activated by your installer. The 'SERVICE' indicator is displayed at set intervals as a reminder that your heating system requires a routine check. Please call your installer to arrange a maintenance visit. The ‘SERVICE’ indicator will remain on the display of the CM727 until it is either reset or disabled by your installer. The CM727 and heating system will continue to operate as normal. • Automatic Summer/Winter Time Change The CM727 has a built-in Automatic Summer/Winter Time Change feature that will automatically adjust the clock forward or backward by one hour for ‘Daylight Saving Time’. This is carried out on the last Sunday of March and October each year. • Optimum Start Optimum Start is a program which ensures that the optimum temperature conditions are achieved at the required times. This is an Energy Efficiency feature that adjusts the start time of your heating system depending upon how cold it is. For example, on cold days your heating system will be started earlier to ensure that your home is warm when you get up (at the target temperature) and on warmer days the heating system will be started later to save energy. So, if the Optimum Start Feature is used, then the time / temperature settings which are entered into the thermostat should be set to when you want to be warm by and not when you want the heating system to start. PROGRAMMING THE CM727 ‘Using the Features’
14 How do I change the batteries on the thermostat when they run out? The thermostat constantly monitors the battery power level, which typically lasts for about 2 years before needing replaced. When the power is running low a flashing symbol will be displayed on the screen. To change the batteries follow the steps in the above section (‘STEP 1: Installing the Batteries’ on page 3), replacing the used batteries with new ones in Step c. Note: While changing the batteries your program settings will be stored but you may need to adjust the time settings to be correct. How do I set one temperature for the whole day? To operate as a simple thermostat with one temperature throughout the day, select the manual operating mode by pressing the MAN button. Adjust the temperature by pressing the or buttons - this can be set anywhere from 5°C to 35°C in 0.5°C steps. The thermostat will continue to maintain this temperature until another operating mode is selected or the temperature is adjusted. FAQ’s BDR91 Relay Box Controls Layout The relay box will normally be found mounted close to the boiler. What does it mean when the BDR91 relay box green LED is ON? The green LED indicates normal operation of the radio frequency system. When the green LED is ON the boiler is also ON. When the LED is OFF the boiler is OFF. When do I need to use the push button? You should use the push button to control your boiler only when the RF communication is lost (see the Troubleshooting Guide). Push button and relay status LED’s This product and its associated documentation and packaging are protected by various intellectual property rights belonging to Honeywell Inc. and its subsidiaries and existing under the laws of the UK and other countries. These intellectual and property rights may include patent applications, registered designs, unregistered designs, registered trade marks, unregistered trade marks and copyrights. Honeywell reserves the right to modify this document, product and functionality without notice. This document replaces any previously issued instructions and is only applicable to the product(s) described. This product has been designed for applications as described within this document. For use outside of the scope as described herein, refer to Honeywell for guidance. Honeywell cannot be held responsible for misapplication of the product(s) described within this document. Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, ACS-ECC EMEA, Z.A. La Pièce 16, 1180 Rolle, Switzerland by its Authorised Representative Honeywell Inc.
15 Symptom Blank Display (Power Loss). Display shows flashing symbol. Display shows symbol. Display shows the word 'SERVICE' BDR91 red LED is constantly on or flashing Remedy Check batteries are installed by removing the battery cover. Check batteries have been installed in the correct orientation. Replace the batteries. The batteries in the thermostat are low on power - Replace the batteries. A fault has occurred in your heating system. Remove and re-insert the batteries. If the symbol does not clear after a few minutes contact your installer. Your installer has set a scheduled maintenance alert period on your CM727 as a recommendation that your heating system should receive a routine inspection. Call your installer to arrange a maintenance visit. Note: The CM727 and heating system will continue to operate as normal. RF communication lost due to the wrong location of the room unit - Hook the room unit back on the wall bracket where RF communication was reliable. Call installer NOTE: You can control the boiler manually when the RF communication is lost: Press the BDR91 push button to switch the boiler on and off. When the green LED is on – the boiler is on. TROUBLESHOOTING THE CM727
16 50039991-003 A© 2009 Honeywell International Inc. Honeywell Control Systems Ltd.Arlington Business Park, Bracknell Berkshire RG12 1EB Technical Help Desk: 08457 678999 www.honeywelluk.com WHAT IS A PROGRAMMABLE ROOM THERMOSTAT? ...an explanation for householdersA programmable room thermostat is both a programmer and a room thermostat. A programmer allows you to set ‘On’ and ‘Off’ time periods to suit your own lifestyle. A room thermostat works by sensing the air temperature, switching on the heating when the air temperature falls below the thermostat setting, and switching it off once this set temperature has been reached. So, a programmable room thermostat lets you choose what times you want the heating to be on, and what temperature it should reach while it is on. It will allow you to select different temperatures in your home at different times of the day (and days of the week) to meet your particular needs. Turning a programmable room thermostat to a higher setting will not make the room heat up any faster. How quickly the room heats up depends on the design of the heating system, for example, the size of boiler and radiators. Neither does the setting affect how quickly the room cools down. Turning a programmable room thermostat to a lower setting will result in the room being controlled at a lower temperature, and saves energy. The way to set and use your programmable room thermostat is to find the lowest temperature settings that you are comfortable with at the different times you have chosen, and then leave it alone to do its job. The best way to do this is to set low temperatures first, say 18°C, and then turn them up by one degree each day until you are comfortable with the temperatures. You won’t have to adjust the thermostat further. Any adjustments above these settings will waste energy and cost you mo\ re money. If your heating system is a boiler with radiators, there will usually be only one programmable room thermostat to control the whole house. But you can have different temperatures in individual rooms by installing thermostatic radiator valves (TRVs) on individual radiators. If you don’t have TRVs, you should choose a temperature that is reasonable for the whole house. If you do have TRVs, you can choose a slightly higher setting to make sure that even the coldest room is comfortable, then prevent any overheating in other rooms by adjusting the TRVs. The time on the programmer must be correct. Some types have to be adjusted in spring and autumn at the changes between Greenwich Mean Time and British Summer Time. You may be able to temporarily adjust the heating programme, for example, ‘Override’, ‘Advance’ or ‘Boost’. These are explained in the manufacturer’s instructions. Programmable room thermostats need a free flow of air to sense the temperature, so they must not be covered by curtains or blocked by furniture. Nearby electric fires, televisions, wall or table lamps may prevent the thermostat from working properly. ®