Page 1
PRODUCT DATA 69- 1360- 2® U.S. Registered Trademark Copyright © 2001 Honeywell • All Rights Reserved Mastertrol® Automatic Balancing System™ (MABS®) EZ Zone (EZ-2 and EZ-4) Control Panels APPLICATION The MABS EZ-2 and EZ-4 are microprocessor-based forced air zone control panels that provide automatic or manual changeover control of single- and two-stage heating and cooling and heat pumps with or without auxiliary heat. FEATURES • MABS EZ-2 controls two zones and MABS EZ-4 control four zones. For...
Page 2
MASTERTROL® AUTOMATIC BALANCING SYSTEM™ (MABS®) EZ ZONE (EZ-2 AND EZ-4) CONTROL PANELS 69-1360–2 2 ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the TRADELINE® Catalog or price sheets for complete ordering number. If you have additional questions, need further information, or would like to comment on our products or services, please write or phone: 1. Your local Home and Building Control Sales Office (check white...
Page 3
MASTERTROL® AUTOMATIC BALANCING SYSTEM™ (MABS®) EZ ZONE (EZ-2 AND EZ-4) CONTROL PANELS 3 69-1360–2 Dampers: See Fig. 3-7 for hookup drawings. See Table 2 for recommended dampers.Accessories: For required accessories, see Table 3. INSTALLATION Mounting CAUTION Equipment Damage Hazard. Do not mount MABS EZ inside HVAC equipment. Mount only on wall or on cold air return 1.Mount the thermostats in each zone of the living space using the installation instructions provided with each thermostat. 2.Mount the...
Page 4
MASTERTROL® AUTOMATIC BALANCING SYSTEM™ (MABS®) EZ ZONE (EZ-2 AND EZ-4) CONTROL PANELS 69-1360–2 4 Wiring Diagrams See Table 1 for recommended thermostats. See Fig. 1-15 for wiring appropriate wiring diagrams. NOTE: The common wire (C to M1) is used only on thermo- stats that require it. Fig. 1. Typical single-stage thermostat hookup diagram. Fig. 2. Heat pump thermostats with separate heat and cool outputs. Use only thermostats listed in Table 1. Fig. 3. AOBD damper wiring (single).NOTE: Wiring is the...
Page 5
MASTERTROL® AUTOMATIC BALANCING SYSTEM™ (MABS®) EZ ZONE (EZ-2 AND EZ-4) CONTROL PANELS 5 69-1360–2 Fig. 7. ML6161 Damper Motor Actuator wiring diagram. NOTE: The R8222 relay is not required for operation, but if it is not used, the zone damper LED will be constantly green. Fig. 8. Transformer wiring diagram. NOTE: A dedicated 40 VA, 24 Vac transformer must be used. Fig. 9. ZoneMAX or C7735 Sensor wiring diagram.Fig. 10. Single-stage heating and cooling equipment wiring diagram. NOTES: — Electric...
Page 6
MASTERTROL® AUTOMATIC BALANCING SYSTEM™ (MABS®) EZ ZONE (EZ-2 AND EZ-4) CONTROL PANELS 69-1360–2 6 Fig. 12. Two-stage heating and cooling wiring diagram. NOTE: The stage timer energizes the second stage equip- ment. Fig. 13. Heat pump wiring diagram. IMPORTANT Y1 must be jumped to W1 for compressor control. Set DIP switch 8 to On to energize the fan with a call for heat. NOTES: — Fossil Fuel Kits with Heat Pumps: The wiring for these heat pumps is similar but the manufac- turers fossil fuel control...
Page 7
MASTERTROL® AUTOMATIC BALANCING SYSTEM™ (MABS®) EZ ZONE (EZ-2 AND EZ-4) CONTROL PANELS 7 69-1360–2 Fig. 14. MABS EZ-2 wiring diagram. C 123X 4567GY RWC ZONE 2 THERMOSTAT 24V, 40 VA TRANSFORMER M19046AAUTOMATIC ROUND DAMPER POWERE CLOSED (ARD-PC) OPPOSED BLADE DAMPERMOTOR ZONE 1 THERMOSTAT ZONE THERMOSTAT ZONE DAMPERSGY RW THIS DIAGRAM SHOWS TYPICAL SINGLE-STAGE THERMOSTAT AND DAMPER MOTOR CONNECTIONS.W2 E W1 B G R O Y1 Y2 TL TL G L ZONE 12ND STG. EMG.THERMOSTAT MOTOR YRWM6M4M1 CR TR1 TR2 HEAT SECOND...
Page 8
MASTERTROL® AUTOMATIC BALANCING SYSTEM™ (MABS®) EZ ZONE (EZ-2 AND EZ-4) CONTROL PANELS 69-1360–2 8 Fig. 15. MABS EZ-4 wiring diagram. STARTUP AND CHECKOUT After the installation is complete, verify the operation: 1.Put the Em Heat switch in the off (down) position. 2.Be sure the DIP switches are set correctly. See Sequence of Operation and Table 6 for correct configu- ration. The default position is in the off (down) position. 3.Power up the MABS EZ and set the thermostats so no zones are calling....
Page 9
MASTERTROL® AUTOMATIC BALANCING SYSTEM™ (MABS®) EZ ZONE (EZ-2 AND EZ-4) CONTROL PANELS 9 69-1360–2 OPERATION Sequence of Operation On a call for heating or cooling, the zone damper to the calling zone stays open, and the dampers close to the zones that are not calling. The MABS EZ panel brings on the heating or cooling and conditioned air is delivered to the calling zone until the zone is satisfied. When the call is satisfied, the system enters the Purge mode. This holds open the damper of the last...
Page 10
MASTERTROL® AUTOMATIC BALANCING SYSTEM™ (MABS®) EZ ZONE (EZ-2 AND EZ-4) CONTROL PANELS 69-1360–2 10 LED Indicators The panel features several LED status indicators visible through a window in the cover. See Table 6. Re-Booting the Microprocessor When conditions hang up the microprocessor, press and release the Boot button to re-boot the system and enter the Purge mode. ZoneMAX Sensor Leaving Air Temperature Sensor The ZMS (not included) is a duct-mounted temperature probe that monitors the supply of...