Bypassing Protection Zones (cont’d) 
 
2. BYPASS  007 FRONT 
UPSTAIRS BEDROOM 
Typical bypass message In  a  few  moments,  all  open  zones  will  be  displayed  
along  with  the  word  BYPASS.  Wait  for  these  zones 
to  be  displayed  before  arming.  Arming  the  system 
before  bypassed  zones  are  displayed  eliminates  all 
bypasses.
 
3. DISARMED BYPASS 
READY TO ARM 
Arm  the  system  as  usual  when  the  keypad  displays 
the  ready  to  arm  message.  Bypassed  zones  are...

Page 32

   
– 32 – 
Bypassing Protection Zones (cont’d) 
 
2. BYPASS  007 FRONT 
UPSTAIRS BEDROOM 
Typical bypass message In a few moments, all the zones in the group will be
 
displayed  along  with  the  word  BYPASS.  Wait  for  
these  zones  to  be  displayed  before  arming.  Arming  
the  system  before  bypassed  zones  are  displayed  
eliminates all bypasses.  
3. DISARMED BYPASS 
READY TO ARM 
Arm  the  system  as  usual  when  the  keypad  displays 
the  ready  to  arm  message.  Bypassed  zones  are...

Page 33

  
– 33 – 
Arming Perimeter Only 
(With Entry Delay ON) 
Using the   3  STAY key 
Use  this  key  when  you  are  staying  home,  but  might  e xpect  someone  to  use 
the entrance door later.  
When  armed  in  STAY  mode,  the  system  will  sound  an  a larm  if  a  protected 
door or window is opened, but you may otherwise mov e freely throughout the 
premises.  Late  arrivals  can  enter  through  the  entra nce  door  without  causing 
an  alarm,  but  they  must  disarm  the  system  within  th e...

Page 34

   
– 34 – 
Arming Perimeter Only 
(With Entry Delay ON) (cont’d) 
Auto-STAY Arming 
Auto-stay  allows  the  system  to  automatically  bypass  certain  zones  if  upon 
arming none of the entry/exit zones are faulted dur ing the exit delay time (no 
one  exits  the  premises).  The  system  provides  an  opt ion  to  set  each  burglary 
zone  for  Auto-stay.  All  zones  enabled  for  auto-stay   except  for  perimeter  and 
day/night types of zones, has exit delay time when  the partition is armed....

Page 35

  
– 35 – 
Arming Perimeter Only 
(With Entry Delay OFF) 
Using the   7  INSTANT Key 
Use this key when you are staying home and do not e xpect anyone to use the 
entrance door.  
When  armed  in  INSTANT  mode,  the  system  will  sound  a n  alarm  if  a 
protected  door  or  window  is  opened,  but  you  may  oth erwise  move  freely 
throughout  the  premises.  The  alarm  will  also  sound  immediately  if  anyone 
opens the entrance door. 
The  system  provides  three  INSTANT  modes:  INSTANT  mo...

Page 36

   
– 36 – 
Arming All Protection 
(With Entry Delay ON) 
Using the   2  AWAY Key 
Use this key when no one will be staying on the pre mises. 
When  armed  in  AWAY  mode,  the  system  will  sound  an  a larm  if  a  protected 
door or window is opened, or if any movement is det ected inside the premises. 
You  may  leave  through  the  entrance  door  during  the  exit  delay  period 
without  causing  an  alarm.  You  may  also  reenter  thro ugh  the  entrance  door, 
but  must  disarm  the  system...

Page 37

  
– 37 – 
Arming all Protection 
(with Entry Delay OFF) 
Using the   4  MAXIMUM Key 
Use  this  key  when  the  premises  will  be  vacant  for  e xtended  periods  of  time 
such  as  vacations,  etc.,  or  when  no  one  will  be  mov ing  through  protected 
interior areas.  
When  armed  in  MAXIMUM  mode,  the  system  will  sound  a n  alarm  if  a 
protected door or window is opened, or if any movem ent is detected inside the 
premises.  You  may  leave  through  the  entrance  door  d uring  the...

Page 38

   
– 38 – 
Quick Exit 
Using the   #  +   9  Keys 
The Quick Exit feature allows you to exit the armed partition without having 
to disarm and then rearm the partition.  
To Quick Exit the premises:  
1.   Press the   # 
 key and then press the    9  key. 
2.   The system will sound the exit beeps, if enabled, a nd will give you the 
programmed exit delay time to leave the premises. 
                              

Page 39

  
– 39 – 
Disarming and Silencing Alarms 
Using the   1  OFF Key 
The OFF  key  is  used  to  disarm  the  system  and  to  silence  ala rm  and  trouble 
sounds.  See  Summary  of  Audible  Notification   section  for  information  that 
will help you to distinguish between FIRE and BURGL ARY alarm sounds. 
IMPORTANT:  If you return and the main burglary sounder is on,  DO NOT enter 
the premises, but call the police from a nearby safe location. If you return after an 
alarm has occurred and the main...

Page 40

   
– 40 – 
Using the Keyswitch 
General 
Your  system  may  be  equipped  with  a  keyswitch  for  use  when  arming  and 
disarming  a  partition.  A  red  and  green  light  on  the   keyswitch  plate  indicate 
the status of your system as follows: 
  Green Light:   Lights  when  the  system  is  disarmed  and  ready to  be 
armed  (no  open  zones).  If  the  system  is  disarmed  an d  the 
green light is off, it indicates the system is not  ready (one or 
more zones are open). 
  Red Light:...