Home > Honeywell > Control panel > Honeywell control panel VISTA128BPVISTA250BP VISTA128SIA User Manual

Honeywell control panel VISTA128BPVISTA250BP VISTA128SIA User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Honeywell control panel VISTA128BPVISTA250BP VISTA128SIA User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 178 Honeywell manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							 
     
    – 71 – 
    Quick Guide to System Functions 
    FUNCTION PROCEDURE COMMENTS 
    Check Zones  Press [✱].  To view faulted zones when is system not ready 
    Display All 
    Descriptors Press and hold [✱] for 5 seconds.  Displays all alpha descriptors programmed by 
    installer. 
    Arm System  Enter code. 
    Press arming key desired (AWAY, 
    STAY, INSTANT, MAXIMUM). Arms system in mode selected. 
    NOTE: After pressing the STAY or INSTANT 
    arming key, enter 1, 2 or 3 to arm in 
    the desired STAY or INSTANT mode. 
    Disarm System  Enter code.  Press OFF [1].  Disarms system and silences alarms. 
    Bypass Zones  Enter code.  Press BYPASS [6]. 
    Enter zone numbers to be 
    bypassed (use 3-digit entries). Bypassed zones are unprotected and will not 
    cause an alarm if violated. 
    Quick Bypass  Enter code.  Press BYPASS [6]. 
    Press [#]. Bypasses all faulted zones automatically. 
    Group Bypass  Enter code.  Press BYPASS [6]. 
    Press [✱].  Enter Group Number 
    (01-15) Bypasses all zones assigned to the group. 
    Chime Mode  Enter code.  Press CHIME [9].  Keypad will sound if doors or windows are 
    violated while system disarmed. 
    Test Mode  Enter code.  Press TEST [5]  Activates alarm sounder and allows sensors to 
    be tested. 
    View Messages  Press and hold [0] for at least 5 
    seconds. Message from central station will appear. 
    View User 
    Capabilities Enter users code.  Press [✱] + [✱].  Displays partitions & authority levels assigned 
    to the user. 
    GOTO Partition  Enter security code.  Press [✱]. 
    Enter partition number (1-8). 
    0 returns to default partition. Allows a user at one keypad to perform 
    functions in another partition, if that user is 
    authorized to do so. 
    Self-Help  Press and hold any function key for 
    at least 5 seconds. Will display abbreviated instructions for the key 
    pressed. 
    Add a User  Enter master/manager code. 
    Press CODE [8]. 
    Enter new users user number. 
    Enter code for that user. 
    Enter authority for that user in this 
    partition (1-5). 
    Follow prompts, 1=Yes, 0=No. Master & Manager level users can add users to 
    the system, each with its own code and 
    authority level. 
    Change a Users 
    Code Enter master/manager code. 
    Press CODE [8]. 
    Enter users 3-digit number. 
    Enter new code for that user. 
    Press 0 (No) at prompt. Master & Manager level users can change their 
    own or other users codes. 
      
    						
    							 
     
    – 72 – 
    Quick Guide to System Functions (cont’d) 
    FUNCTION PROCEDURE COMMENTS 
    Delete a User  Enter master/manager code. 
    Press CODE [8]. 
    Enter user no. to be deleted. 
    Enter master/manager code. 
    Press 1 (Yes) at prompt. Master & Manager level users can delete users. 
    A user can only be deleted by a user with higher 
    authority level. 
    Real-Time Clock 
     Enter Master code.  Press [#] + [63] 
     Press [✳] or [#] to move cursor. Enter time and 
    date accordingly. Press any key (0-9) for 
    AM/PM. 
    Enter security code.  Press [#] 
    Enter 71 or 72. Activate output device as programmed. Control Output 
    Device 
    Enter security code.  Press [#] 
    Enter 70. Activate output device manually 
    Enter security code.  Press [#] 
    Enter 77. Activate output device or system event instantly 
    Enter security code.  Press [#] 
    Enter 41 Randomize output devices set for random 
    schedules 
    Randomize 
    Output Device 
    Enter security code.  Press [#] 
    Enter 42. Randomize output devices set for random 
    schedules with activation times between 6 PM 
    and 5 AM 
    Enter the sequence used to 
    activate randomization. De-activate randomization 
    Enter security code (002-050) 
    Press [#].  Enter 86. Activate single-panel single-partition mode. 
    Enter security code (002-050) 
    Press [#].  Enter 85. Exit single-panel single-partition mode. 
    Enter security code (002-050) 
    Press [#].  Enter 88. Activate multi-partition multi-panel mode. 
    Panel Linking 
    Enter security code (002-050) 
    Press [#].  Enter 87. Activate multi-panel view mode. 
    Enter 0.  Exit multi-partition multi-panel mode and multi-
    panel view mode. 
    Enter security code.  Enter 0.  Activate access relay for current partition. 
    Enter security code 
    Press [#].  Enter 73. Request to enter or exit at a console. 
    Enter security code 
    Press [#].  Enter 74. 
    Enter access point number. Request to enter or exit at an access point. 
    Access Control 
    Enter security code.  Press [#]. 
    Enter 75. Enter access point 
    number. 
    Enter state (1-3) Change the access point state. 
      
    						
    							 
     
    – 73 – 
    Summary of Audible Notification 
    (Alpha Display Keypads) 
    SOUND CAUSE  DISPLAY 
    LOUD, 
    INTERRUPTED* 
     Keypad & External FIRE ALARM FIRE is displayed; descriptor of zone in alarm is 
    displayed. 
    LOUD, 
    CONTINUOUS* 
     Keypad & External BURGLARY/AUDIBLE EMERGENCY 
    ALARM  AL ARM is displayed; descriptor of zone in alarm is 
    also displayed. 
    ONE SHORT BEEP 
     (not repeated) 
    Keypad only a. SYSTEM DISARM   
    b.  SYSTEM ARMING ATTEMPT 
    WITH AN OPEN ZONE. 
    c.  BYPASS VERIFY  a. DISARMED/READY TO ARM is displayed.  
    b. The number and descriptor of the open protection 
    zone is displayed. 
    c.  Numbers and descriptors of the bypassed 
    protection zones are displayed (One beep is heard 
    for each zone displayed). Subsequently, the 
    following is displayed: DISARMED BYPASS Ready 
    to Arm 
    ONE SHORT BEEP 
      (once every 15 
    sec.) Keypad only SYSTEM IS IN TEST MODE  Opened Zone identifications will appear. 
    TWO SHORT BEEPS 
      (once every 5 sec.) 
    Keypad only SYSTEM IS ABOUT TO 
    AUTOMATICALLY EXIT TEST 
    MODE Opened Zone identifications will appear. 
    ONE BEEP 
      (every 60 sec.)  
    Keypad only LOW BATTERY AT A TRANSMITTER LO BAT displayed with description of transmitter. 
    TWO SHORT BEEPS  
      Keypad only  ARM AWAY OR MAXIMUM     ARM ED AW AY or ARM ED M AXIM UM is displayed. 
    Red ARMED indicator is lit. 
    THREE SHORT 
    BEEPS 
     Keypad only a. ARM STAY OR INSTANT   
    b. ZONE OPENED WHILE SYSTEM 
    IS IN CHIME MODE.   
    c. ENTRY WARNING** a. ARMED STAY ZONE BYPASSED or ARM ED 
    INSTANT ZONE BYPASSED is displayed. Red 
    ARMED indicator is lit. 
    b. CHIME displayed, descriptor of open protection 
    zone will be displayed if the [✱] key is pressed. 
    c. DISARM SYSTEM OR ALARM WILL OCCUR is 
    displayed. 
    RAPID BEEPING  
     Keypad only a. TROUBLE   
    b. AC POWER LOSS ALERT*** 
    c.  MEMORY OF ALARM  a. CHECK displayed.  Descriptor of troubled 
    protection zone is displayed. 
    b. AC LOSS displayed (may alternate with other 
    displays that may be present). 
    c. FIRE or AL ARM  is displayed; descriptor of zone in 
    alarm is displayed.  
    SLOW BEEPING  
     Keypad only a. ENTRY DELAY WARNING**  
    b. EXIT DELAY WARNING  
     (if programmed) a. DISARM SYSTEM OR ALARM WILL OCCUR is 
    displayed. Exceeding the delay time without 
    disarming causes alarm.  
    b. ARM ED AW AY or ARMED MAXIMUM is displayed 
    along with You May Exit Now 
    *  If bell is used as external sounder, fire alarm is pulsed ring; burglary/audible emergency is steady ring.  
    **  Entry warning may consist of three short beeps or slow continuous beeping, as programmed by your installer. 
    ***  Loss of system battery power is not indicated or annunciated by the keypad (warnings are for loss of AC power 
    only).  
      
    						
    							 
     
    – 74 – 
    FEDERAL COMMUNICATIONS COMMISSION STATEMENTS 
    The user shall not make any changes or modifications to the equipment unless authorized by the Installation 
    Instructions or Users Manual. Unauthorized changes or modifications could void the users authority to 
    operate the equipment.  FCC CLASS B STATEMENT 
    This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC 
    requires the following statement for your information:  This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in 
    strict accordance with the manufacturers instructions, may cause interference to radio and television 
    reception. It has been type tested and found to comply with the limits for a Class B computing device in 
    accordance with the specifications in Part 15 of FCC Rules, which are designed to provide reasonable 
    protection against such interference in a residential installation. However, there is no guarantee that 
    interference will not occur in a particular installation. If this equipment does cause interference to radio or 
    television reception, which can be determined by turning the equipment off and on, the user is encouraged 
    to try to correct the interference by one or more of the following measures: 
      If using an indoor antenna, have a quality outdoor antenna installed. 
      Reorient the receiving antenna until interference is reduced or eliminated. 
      Move the radio or television receiver away from the receiver/control. 
      Move the antenna leads away from any wire runs to the receiver/control. 
      Plug the receiver/control into a different outlet so that it and the radio or television receiver are on different 
    branch circuits. 
      Consult the dealer or an experienced radio/TV technician for help.  INDUSTRY CANADA CLASS B STATEMENT 
    ICES-003 Class B Notice - Avis NMB-003, Classe B 
    This Class B digital apparatus complies with Canadian ICES-003. 
    Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.  FCC/IC STATEMENT 
    This device complies with Part 15 of the FCC Rules, and RSS 210 of IC. Operation is subject to the 
    following two conditions: (1) This device may not cause harmful interference (2) This device must accept 
    any interference received, including interference that may cause undesired operation. 
    Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS 210 des Industries Canada. Son 
    fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne doit pas causer d interferences 
    nuisibles. (2) Cet appareil doit accepter toute interference reçue y compris les interferences causant une 
    reception indésirable. 
     
    IN THE EVENT OF TELEPHONE OPERATIONAL PROBLEMS 
    In the event of telephone operational problems, disconnect the control by removing the plug from the RJ31X 
    (CA38A in Canada) telephone wall jack. We recommend that your certified installer demonstrate 
    disconnecting the phones on installation of the system. Do not disconnect the phone connection inside the 
    control/communicator. Doing so will result in the loss of your phone lines. If the regular phone works 
    correctly after the control/communicator has been disconnected from the phone lines, the 
    control/communicator has a problem and should be returned for repair. If upon disconnection of the 
    control/communicator, there is still a problem on the line, notify the telephone company that they have a 
    problem and request prompt repair service. The user may not under any circumstances (in or out of 
    warranty) attempt any service or repairs to the system. It must be returned to the factory or an authorized 
    service agency for all repairs.  
    						
    							 
     
    – 75 – 
     
     “FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 68 NOTICE 
    This equipment complies with Part 68 of the FCC rules. On the front cover of this equipment is a 
    label that contains, among other information, the FCC registration number and ringer equivalence 
    number (REN) for this equipment. If requested, this information must be provided to the 
    telephone company. 
    This equipment uses the following jacks: 
      An RJ31X is used to connect this equipment to the telephone network. 
    The REN is used to determine the quantity of devices which may be connected to the telephone 
    line. Excessive RENs on the telephone line may result in the devices not ringing in response to 
    an incoming call. In most, but not all areas, the sum of the RENs should not exceed five (5.0). To 
    be certain of the number of devices that may be connected to the line, as determined by the total 
    RENs, contact the telephone company to determine the maximum REN for the calling area. 
    If this equipment causes harm to the telephone network, the telephone company will notify you in 
    advance that temporary discontinuance of service may be required. If advance notice is not 
    practical, the telephone company will notify the customer as soon as possible. Also, you will be 
    advised of your right to file a complaint with the FCC if you believe necessary. 
    The telephone company may make changes in its facilities, equipment, operations, or procedures 
    that could affect the operation of the equipment. If this happens, the telephone company will 
    provide advance notice in order for you to make the necessary modifications in order to maintain 
    uninterrupted service. 
    If trouble is experienced with this equipment, please contact the manufacturer for repair and 
    warranty information. If the trouble is causing harm to the telephone network, the telephone 
    company may request you remove the equipment from the network until the problem is resolved. 
    There are no user serviceable components in this product, and all necessary repairs must be 
    made by the manufacturer. Other repair methods may invalidate the FCC registration on this 
    product. 
    This equipment cannot be used on telephone company-provided coin service. Connection to 
    Party Line Service is subject to state tariffs. 
    This equipment is hearing-aid compatible. 
    When programming or making test calls to an emergency number, briefly explain to the 
    dispatcher the reason for the call. Perform such activities in the off-peak hours; such as early 
    morning or late evening. 
     
     
     
     
     
     
      
    						
    							 
     
    – 76 – CANADIAN DEPARTMENT OF COMMUNICATIONS  
    (DOC) STATEMENT 
     
    NOTICE 
    The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational and safety requirements. The Department does not guarantee the equipment will operate to the user’s satisfaction. 
    Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. In some cases, the company’s inside wiring associated with a single line individual service may be extended by means of certified connector assembly (telephone extension cord). The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations. 
    Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment. 
    Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas. 
    Caution:  User should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate. 
    The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device, to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the requirement that the total of the Load Numbers of all the devices does not exceed 100. 
    AVIS 
    L’étiquette du ministère des Communications du Canada identifie le matériel homologué.  Cette étiquette certifie que le matériel est conforme à certaines normes de protection, d’exploitation et de sécurité des réseaux de télécommunications. Le ministère n’assure toutefois pas que le matériel fonctionnera à la satisfaction de l’utilisateur. 
    Avant d’installer ce matériel, l’utilisateur doit s’assurer qu’il est permis de le raccorder aux installations de l’entreprise locale de télécommunications. Le matériel doit également être installé en suivant une méthode acceptée de raccordement. Dans certains cas, les fils intérieurs de l’entreprise utilisés pour un service individuel à la ligne unique peuvent être prolongés au moyen d’un dispositif homologué de raccordement (cordon prolongateur téléphonique interne). L’abonné ne doit pas oublier qu’il est possible que la conformité aux conditions énoncées ci-dessus n’empèchet pas la dégradation du service dans certaines situations. Actuellement, les entreprises de télécommunications ne permettent pas que l’on raccorde leur matériel aux  prises d’abonnés, sauf dans les cas precis prévus par les tarifs particuliers de ces entreprises. 
    Les réparations du matériel homologué doivent être effectuées pas un centre d’entretien canadien autorisé désigné par le fournisseur. La compagnie de télécommunications peut demander à l’utilisateur de débrancher un appareil à la suite de réparations ou de modifications effectuées par l’utilisateur ou à cause de mauvais fonctionnement. 
    Pour sa propre protection, l’utilisateur doit s’assurer que tous les fils de mise en terre de la source d’énergie électrique, des lignes téléphoniques de réseau de conduites d’eau s’il y en a, soient raccordés ensemble. Cette précaution est particulièrement importante dans les régions rurales. 
    Avertissement:  L’utilisateur ne doit pas tenter de faire ces raccordements lui-même; il doit avoir recours à un service d’inspection des installations électriques, ou à un électricien, selon le cas. 
    L’indice de charge (IC) assigné à chaque dispositif terminal pour éviter toute surcharge indique le pourcentage de la charge totale qui peut être raccordé à un circuit  téléphonique bouclé utilisé par ce dispositif. La terminaison du circuit bouclé peut être constituée de n’importe quelle combinaison de dispositifs, pourvu que la somme des indices de charge de l’ensemble des dispositifs ne dépasse pas 100. 
      
    						
    							 
     
    – 77 – 
    WARNING!   
    THE LIMITATIONS OF THIS ALARM SYSTEM While this system is an advanced design security system, it does not offer guaranteed protection against burglary or fire or other emergency. Any alarm system, whether commercial or residential, is subject to compromise or failure to warn for a variety of reasons. For example:   Intruders may gain access through unprotected openings or have the technical sophistication to bypass an alarm sensor or disconnect an alarm warning device.   Intrusion detectors (e.g. passive infrared detectors), smoke detectors, and many other sensing devices will not work without power. Battery operated devices will not work without batteries, with dead batteries, or if the batteries are not put in properly. Devices powered solely by AC will not work if their AC power supply is cut off for any reason, however briefly.   Signals sent by wireless transmitters may be blocked or reflected by metal before they reach the alarm receiver. Even if the signal path has been recently checked during a weekly test, blockage can occur if a metal object is moved into the path.   A user may not be able to reach a panic or emergency button quickly enough.   While smoke detectors have played a key role in reducing residential fire deaths in the United States, they may not activate or provide early warning for a variety of reasons in as many as 35% of all fires, according to data published by the Federal Emergency Management Agency. Some of the reasons smoke detectors used in conjunction with this System may not work are as follows. Smoke detectors may have been improperly installed and positioned. Smoke detectors may not sense fires that start where smoke cannot reach the detectors, such as in chimneys, in walls, or roofs, or on the other side of closed doors. Smoke detectors also may not sense a fire on another level of a residence or building. A second floor detector, for example, may not sense a first floor or basement fire. Moreover, smoke detectors have sensing limitations. No smoke detector can sense every kind of fire every time. In general, detectors may not always warn about fires caused by carelessness and safety hazards like smoking in bed, violent explosions, escaping gas, improper storage of flammable materials, overloaded electrical circuits, children playing with matches, or arson. Depending upon the nature of the fire and/or the locations of the smoke detectors, the detector, even if it operates as anticipated, may not provide sufficient warning to allow all occupants to escape in time to prevent injury or death.   Passive Infrared Motion Detectors can only detect intrusion within the designed ranges as diagrammed in their installation manual. Passive Infrared Detectors do not provide volumetric area protection. They do create multiple beams of protection, and intrusion can only be detected in unobstructed areas covered by those beams. They cannot detect motion or intrusion that takes place behind walls, ceilings, floors, closed doors, glass partitions, glass doors, or windows. Mechanical tampering, masking, painting or spraying of any material on the mirrors, windows or any part of the optical system can reduce their detection ability. Passive Infrared Detectors sense changes in temperature; however, as the ambient temperature of protected area approaches the temperature range of 90° to 105°F, the detection performance can decrease.   Alarm warning devices such as sirens, bells or horns may not alert people or wake up sleepers if they are located on the other side of closed or partly open doors. If warning devices sound on a different level of the residence from the bedrooms, then they are less likely to waken or alert people inside the bedrooms. Even persons who are awake may not hear the warning if the alarm is muffled from a stereo, radio, air conditioner or other appliance, or by passing traffic. Finally, alarm warning devices, however loud, may not warn hearing-impaired people or waken deep sleepers.   Telephone lines needed to transmit alarm signals from a premises to a central monitoring station may be out of service or temporarily out of service. Telephone lines are also subject to compromise by sophisticated intruders.   Even if the system responds to the emergency as intended, however, occupants may have insufficient time to protect themselves from the emergency situation. In the case of a monitored alarm system, authorities may not respond appropriately.   This equipment, like other electrical devices, is subject to component failure. Even though this equipment is designed to last as long as 10 years, the electronic components could fail at any time. The most common cause of an alarm system not functioning when an intrusion or fire occurs is inadequate maintenance. This alarm system should be tested weekly to make sure all sensors and transmitters are working properly. Installing an alarm system may make one eligible for lower insurance rates, but an alarm system is not a substitute for insurance. Homeowners, property owners and renters should continue to act prudently in protecting themselves and continue to insure their lives and property. We continue to develop new and improved protection devices. Users of alarm systems owe it to themselves and their loved ones to learn about these developments.  
    						
    							 
     
    – 78 – 
    Index 
    #70 command ............................................... 50 
    4286 VIP module ..................................... 9, 50 
    AC Loss ........................................................ 65 
    Access Another Partition....................... 22 
    Access Control Commands .......................... 58 
    Access Door .................................................. 49 
    Action Code
    ............................................... 57 
    Action Specifier
    ........................................ 57 
    Add a User................................................. 18 
    ADD NEW USER ........................................ 20 
    Add User Code ............................................. 17 
    Ademco Dealer............................................. 65 
    Advanced User Interface.................... 5, 10 
    Alarm ............................................................. 7 
    Alkaline batteries ........................................ 69 
    Alpha Keypads............................................. 10 
    Arm/Disarm Commands ............................. 57 
    Armed ............................................................ 7 
    ARMED INDICATOR............................... 13 
    Audible Emergency ..................................... 46 
    Audible Signals............................................ 73 
    Authority Level............................................ 15 
    Authority Levels .................................... 16, 17 
    Auto-STAY Arming ..................................... 37 
    Away ........................................................ 7, 22 
    AWAY .......................................................... 43 
    AWAY mode................................................. 39 
    battery life ................................................... 69 
    Burglary ......................................................... 5 
    Burglary Protection ....................................... 7 
    Bypass- Access Door .................................... 49 
    Bypass Commands ...................................... 58 
    Bypass Zones ............................................... 33 
    Bypassing................................................... 33 
    Call Service .................................................. 64 
    Change a Users Code.............................. 20 
    Change User Code ....................................... 17 
    CHECK....................................................... 64 
    Chime ....................................................... 7, 44 
    Closing Time ................................................ 51 
    Comm. Failure ............................................. 64 
    Common Lobby ............................................ 25 Delaying Closing Time............................ 51 
    Delete a User............................................. 21 
    Delete User Code ......................................... 17 
    Descriptors ................................................... 32 
    Device Timers....................................... 8, 54 
    Disarm.......................................................... 42 
    Displays for Multi-Partition and Multi-Panel 
    Modes ....................................................... 30 
    DOC .............................................................. 76 
    Duress .......................................................... 16 
    Duress Code............................................... 15 
    Emergency ..................................................... 5 
    Entry Delay.................................................. 14 
    Entry/Exit ...................................................... 6 
    Event Log Procedures.................................. 60 
    Exit Delay .................................................... 14 
    Exit User Edit Mode................................ 17 
    FCC .............................................................. 74 
    Fire ........................................................... 5, 46 
    fire alarm ..................................................... 63 
    Fire Display Lock......................................... 63 
    Fire Protection ............................................... 6 
    GLOBAL ARM ............................................. 19 
    Global Arming.............................................. 22 
    Goto .............................................................. 19 
    GOTO ........................................................... 22 
    GOTO Command ........................................... 8 
    Grant- Access Door ...................................... 49 
    Group Bypass ............................................... 35 
    How to Use Panel Linking .......................... 27 
    Instant...................................................... 7, 22 
    INSTANT ..................................................... 14 
    INSTANT mode ........................................... 38 
    Keypad ........................................................... 5 
    Keypad back lighting................................... 10 
    Keypads ........................................................ 10 
    Keyswitch ..................................................... 43 
    LO Bat .......................................................... 65 
    Low Battery ................................................. 69 
    Low Battery Warning.............................. 70 
    macro ............................................................ 47 
    Macros ............................................................ 8  
    						
    							 
     
    – 79 – 
    Manager ....................................................... 16 
    Master .......................................................... 16 
    Master Keypad......................................... 9, 23 
    Maximum ................................................. 7, 22 
    MAXIMUM .................................................. 14 
    MAXIMUM mode......................................... 40 
    Memory of Alarm.................................. 8, 42 
    Messages ...................................................... 45 
    Modem Comm .............................................. 65 
    MULTI-ACCESS ......................................... 19 
    Multi-Panel View Mode ............................... 29 
    Multi-Partition Multi-Panel Mode .............. 28 
    NFPA............................................................ 66 
    NIGHT......................................................... 38 
    Not Ready..................................................... 31 
    Off ................................................................. 22 
    OFF .............................................................. 42 
    Open Zones................................................ 31 
    Open/Close Schedules............................. 51 
    Open/Close Windows ................................... 58 
    Operator A ................................................... 16 
    Operator B ................................................... 16 
    Operator C ................................................... 16 
    OUTPUT TIMER ......................................... 54 
    Panel Linking .......................................... 6, 27 
    Panic Keys................................................. 46 
    PANIC KEYS.............................................. 13 
    Partitioned System ........................................ 6 
    Personal Emergency .................................... 46 
    Phone Access .................................................. 9 
    Power............................................................ 65 
    POWER/READY INDICATOR................ 13 
    Protect- Access Door .................................... 49 
    Quick Arm .................................................... 13 
    Quick Arming............................................ 15 
    Quick Bypass............................................. 34 
    Quick Exit .................................................... 41 
    Quick Guide ........................................... 71, 72 
    Randomize Output Devices ......................... 56 
    Ready.......................................................... 31 READY .........................................................44 
    Ready Key ....................................................31 
    Real-Time Clock ...........................................72 
    Relay commands ..........................................57 
    Relay Menu Mode.....................................50 
    Replacing Batteries.................................69 
    RF BUTTON ................................................18 
    Routine Care.............................................70 
    Schedules..................................................8, 51 
    Security Code ...............................................15 
    Security Codes..............................................15 
    Sensing Devices..............................................6 
    Silencing A Fire Alarm ................................63 
    Silent Emergency .........................................46 
    Single-Partition Single-Panel Mode............27 
    Smoke Detectors ..........................................62 
    Speed Key .....................................................47 
    SPEED KEY ...................................................8 
    Stay...........................................................7, 22 
    STAY.............................................................43 
    STAY mode...................................................36 
    System LO Bat .............................................65 
    Temporary Schedules ............................51, 52 
    Temporary Users .........................................18 
    Test Key........................................................62 
    Test mode .....................................................62 
    Testing Your System....................................62 
    Time Window ...............................................51 
    TRBL...........................................................64 
    Trouble Condition ........................................64 
    UNABLE TO ARM LOBBY .........................25 
    User Edit Mode ............................................17 
    User Numbers ..............................................15 
    Users Instructions .........................................9 
    Using #77 Instant Activation Mode ............57 
    Wireless Sensor ............................................69 
    Zone Bypassed..............................................36 
    Zone Descriptors ..........................................32 
    Zones.............................................................6
      
    						
    							 
     
    ÊK5895V5*Š 
    K5895V5 4/09 Rev C  
     TWO YEAR LIMITED WARRANTY  Honeywell International Inc., acting through its Security & Communications business (“Seller”), 2 Corporate Center Drive, Melville, New York 11747 warrants its products to be free from defects in materials and workmanship under normal use and service, normal wear and tear excepted, for 24 months from the manufacture date code; provided, however, that in the event the Buyer presents a proper invoice relating to the purchased product and such invoice bears a date later than the manufacture date, then Seller may at its discretion, reflect the warranty period as commencing at invoice date. Except as required by law, this Limited W arranty is only made to Buyer and may not be transferred to any third party. During the applicable warranty period, Seller will repair or replace, at its sole option and as the exclusive remedy hereunder, free of charge, any defective products.  Seller shall have no obligation under this Limited W arranty or otherwise if the product:     (i)  is improperly installed, applied or maintained;   (ii)  installed outside of stated operating parameters, altered or improperly serviced or repaired by anyone other than the Seller/Seller’s Authorized Service/Repair Center;   (iii)  damage is caused by outside natural occurrences, such as lightning, power surges, fire, floods, acts of nature, or the like; or   (iv)  defects result from unauthorized modification, misuse, vandalism, alterations of serial numbers, other causes unrelated to defective materials or workmanship, or failures related to batteries of any type used in connection with the products sold hereunder.  Exceptions to Warranty With Respect to Honeywell Products listed below:  Hardwire Contacts and PIRs – Seller warrants parts for hardwire contacts and PIRs in accordance with the terms of the above limited warranty for a period of five (5) years from the manufacture date code.  EXCLUSION OF WARRANTIES, LIMITATION OF LIABILITY  THERE ARE NO W ARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, OF MERCHANTABILITY, OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERW ISE, WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. TO THE FULLEST EXTENT PERMITTED BY LAW , IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY (i) CONSEQUENTIAL, INCIDENTAL, INDIRECT, SPECIAL, OR PUNITIVE DAMAGES ARISING OUT OF OR RELATING IN ANY W AY TO THE PRODUCT AND/OR FOR BREACH OF THIS OR ANY OTHER WARRANTY OR CONDITION, EXPRESS OR IMPLIED, OR UPON ANY OTHER BASIS OF LIABILITY W HATSOEVER, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY SELLER’S OW N NEGLIGENCE OR FAULT AND EVEN IF SELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH LOSSES OR DAMAGES. Any product description (whether in writing or made orally by Seller or Seller’s agents), specifications, samples, models, bulletin, drawings, diagrams, engineering sheets or similar materials used in connection with the Buyer’s order are for the sole purpose of identifying the Seller’s products and shall not be construed as an express warranty or condition. Any suggestions by Seller or Seller’s agents regarding use, applications, or suitability of the products shall not be construed as an express warranty or condition unless confirmed to be such in writing by Seller. Seller does not represent that the products it sells may not be compromised or circumvented; that the products will prevent any personal injury or property loss by burglary, robbery, fire or otherwise, or that the products will in all cases provide adequate warning or protection. Buyer understands that a properly installed and maintained alarm may only reduce the risk of a burglary, robbery or fire without warning, but it is not insurance or a guarantee that such will not occur or will not cause or lead to personal injury or property loss. CONSEQUENTLY, SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY, PROPERTY DAMAGE OR OTHER LOSS BASED ON ANY CLAIM AT ALL INCLUDING A CLAIM THE PRODUCT FAILED TO GIVE WARNING. However, if Seller is held liable whether directly or indirectly for any loss or damage with respect to the products it sells, regardless of cause or origin, its maximum liability shall not in any case exceed the purchase price of the product, which shall be fixed as liquidated damages and not as a penalty, and shall be the complete and exclusive remedy against the Seller. Should your product become defective during the warranty, please contact your installer to facilitate repair or replacement with Seller pursuant to the terms hereof. Seller reserves the right to replace any defective product under warranty with new, refurbished, or remanufactured product.   
     
    2 Corporate Center Drive, Suite 100
    P.O. Box 9040, Melville, NY 11747
    Copyright © 2009 Honeywell International Inc.
    www.honeywell.com/security
      
    						
    All Honeywell manuals Comments (0)

    Related Manuals for Honeywell control panel VISTA128BPVISTA250BP VISTA128SIA User Manual