Home > Honeywell > Control panel > Honeywell control panel OMNI 408408EU User Manual

Honeywell control panel OMNI 408408EU User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Honeywell control panel OMNI 408408EU User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 178 Honeywell manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							 
    N9942-2V2 4/04 Rev. A 
      
     
    FBII Security System
    FBII Security SystemFBII Security System FBII Security System 
          
        
    O
    OO O O
    OO O
    M
    MM M M
    MM M
    N
    NN N N
    NN N
    I
    II I I
    II I®
    -
    -- - -
    -- -
    4
    44 4 4
    44 4
    0
    00 0 0
    00 0
    8
    88 8 8
    88 8
     
          
        
    O
    OO O O
    OO O
    M
    MM M M
    MM M
    N
    NN N N
    NN N
    I
    II I I
    II I®
    -
    -- - -
    -- -
    4
    44 4 4
    44 4
    0
    00 0 0
    00 0
    8
    88 8 8
    88 8
    E
    EE E E
    EE E
    U
    UU U U
    UU U
     
    User Guide 
        
     
     
     
     
      
    						
    							 
    – 3 – 
    Table Of Contents 
    QUICK REFERENCE ............................................................................................. 4 
    Arming the System ............................................................................................ 4 
    Disarming the System ....................................................................................... 4 
    Arm System/Stay Inside .................................................................................... 4 
    Arm System/Stay Inside/Instant Mode .............................................................. 4 
    Smoke Detector Reset ...................................................................................... 4 
    INTRODUCTION .................................................................................................... 6 
    SYSTEM REFERENCE ......................................................................................... 7 
    SYSTEM OPERATION ........................................................................................ 10 
    To Arm the System and Leave ....................................................................... 10 
    When the System is Not Ready ...................................................................... 11 
    To Arm the System and Stay Inside ............................................................... 11 
    To Arm the System In Instant Mode and Stay Inside ..................................... 12 
    To Arm the System In Instant Mode ............................................................... 13 
    To Bypass a Zone ........................................................................................... 13 
    To Unbypass a Zone ....................................................................................... 14 
    Disarming the System ..................................................................................... 14 
    USER CODES...................................................................................................... 16 
    Adding/Changing a User Code ....................................................................... 16 
    Deleting a User Code ...................................................................................... 16 
    PAGING FEATURE.............................................................................................. 17 
    Follow-Me Displays ......................................................................................... 17 
    Changing the Pager Follow-Me Phone Number ............................................. 17 
    MISCELLANEOUS COMMANDS ........................................................................ 19 
    TESTING THE SYSTEM ...................................................................................... 22 
    System Test .................................................................................................... 22 
    Battery Test ..................................................................................................... 22 
    RECOMMENDATIONS ON SMOKE DETECTORS ............................................ 23 
    EMERGENCY EVACUATION.............................................................................. 24 
    RADIO FREQUENCY EMISSIONS STATEMENTS.................................... 25 
    FEDERAL COMMUNICATIONS COMMISSION (FCC) PART 15 ....................... 25 
    TELEPHONE/MODEM INTERFACE STATEMENTS................................. 25 
    TELEPHONE OPERATIONAL PROBLEMS................................................. 26 
     O560 DECLARATION OF CONFORMITY............................................... 26 
    SYSTEM LIMITATIONS ....................................................................................... 27 
    GLOSSARY.......................................................................................................... 29  
    						
    							– 4 – 
    Quick Reference 
    Arming the System 
    Check to make sure the system is ready — Green READY LED is lit. 
    Enter your 4-digit User Code (or press the ARM button on your 
    keyfob). 
    The ARMED LED goes on. 
    Exit through a door designated by your installer as an exit/entry door.  
    Disarming the System 
    Enter through door designated by your installer as an exit/entry door.  
    Enter your 4-digit User Code (or press the DISARM button on your 
    keyfob). 
    The ARMED LED goes out. 
    Arm System/Stay Inside  
    Check to make sure the system is ready — Green READY LED is lit. 
    Press  STAY  followed by your User Code.
     
    The ARMED and STAY LEDs light. 
     
    You must disarm the system if you want to open the door or leave the premises 
    after the exit time has passed. 
    Arm System/Stay Inside/Instant Mode 
    Check to make sure the system is ready — Green READY LED is lit.  
    Press INSTANT thenSTAY  followed by your User Code.
     
     
    The ARMED, INSTANT, and STAY LEDs are all lit.  
    Smoke Detector Reset 
    Enter your 4-digit User Code. 
      
    						
    							 
    – 5 – 
    Quick Reference (cont’d) 
    The following table lists the “Quick Commands” available with this control. 
     
    Keystroke Quick Command  Keypads  Description 
     #  1 Quick Arm   All keypads If system is ready, allows you to arm the system without 
    requiring your User Code.  Your User Code is always 
    needed to disarm the system. 
     #  2 Force Arm    All keypads Allows you to arm the system even if some zones are 
    faulted.  These zones are automatically bypassed and are 
    unprotected. 
    [BYPASS] + 
    Zone No. Quick Bypass   All keypads Allows you to bypass a specific zone number.  Must be 
    enabled by your installer. 
     #  3 Set Time  All keypads Allows entry of the current system time (hours, minutes, 
    month, day, year).  
     #  4 Zone Directory  LCD only  Displays listing of zones in system.  
     #  55 Display Firmware Version  LCD only  Displays version of your OMNI-408 firmware. 
     #  56 Display Keyfob Battery Status  All keypads Allows you to test battery status of your keyfob.  Upon 
    entry of this mode, press any button on the keyfob and the 
    keypad will display if your battery is low. 
     #  58 Change/View Pager Number  All keypads Allows you to redirect pager output to a different pager 
    number.  Phone numbers are displayed only on LCD 
    keypads. 
     #  6 Display/Toggle Chime Mode  All keypads  Allows you to change the status of the chime function. 
     #  7 Display Current Time  LCD only  Allows you to view the current system time. 
     #  8 User Page Toggle  All keypads Allows you to turn the pager mode on or off.  Keypad 
    displays the current system status. 
      
    						
    							– 6 – 
    Introduction 
    Congratulations on your decision to protect your home or business 
    with the OMNI®
    -408 security system.  You have chosen a reliable, 
    state-of-the-art security system that is remarkably easy to operate.  
    Representatives from your local security company, who can explain 
    the specifics of your system, have professionally installed your system. 
    The keypad is the input and display device for your security system.  
    Your system can use either the OMNI-KP, OMNI-KP-US, OMNI-LCD, 
    OMNI-LCD-US, XK7LC, or XK108 keypads.  The OMNI-KP and 
    OMNI-KP-US keypads display the system status with fixed words, the 
    OMNI-LCD, OMNI-LCD-US, and XK7LC keypads display two lines of 
    text, and the XK108 keypad displays the current zone status, 
    including alarms, bypasses, and faults, using LEDs.  Each condition 
    causes the LEDs to operate differently. 
    Throughout this guide, the following conventions are used to display 
    the keystrokes required to perform functions. 
    BYPASS 
    Key labeled [BYPASS] 
     
    INSTANT 
    Key labeled [INSTANT] 
     
    STAY 
    Key labeled [STAY] 
     
    CODE 
    Key labeled [CODE] 
     
                               Enter your four-digit User Code.   
    Please keep your guide in a convenient location so you can refer to it if 
    needed.  
    						
    							 
    – 7 – 
    System Reference 
    ZONE DESCRIPTION 
    1  
    2  
    3  
    4  
    5  
    6  
    7  
    8  
     
    ENTRY 
    TIME 1   
    DOOR  EXIT 
    TIME*  
    ENTRY 
    TIME 2   
    DOOR    
    * Exit time is the same for all designated entry/exit doors. 
    The following SEND HELP ALERTS can be programmed into your 
    system.  Both keys must be pressed at the same time to activate the 
    alert.  The keys you press depend on which type of keypad you have.  
    Your installer will show you how to activate these emergency keys. 
    DESCRIPTION KEYS 
     [#] and [*] 
     [7] and [9] 
     [1] and [3] 
     
     
    See page 8 of this User Guide for pictures of the OMNI-KP,OMNI-KP-US, OMNI-
    LCD, OMNI-LCD-US, XK7LC, and XK108 keypads.  
    						
    							– 8 – 
    System Reference (cont’d) 
    OMNI-KP,OMNI-KP-US AND XK108 KEYPADS 
     
    ALARMFIRE
    INSTANT
    BYPASS
    TRBL
    PAGE
    STAY
    SUPRVSNCANCELEDCHIME
    BAT NOT  READY PHONE
    TEST
    TAMPER   NO  AC
     
    OMNI-KP Fixed-Word Keypad 
     
    ALARMFIRE
    INSTANT
    BYPASS
    TRBL
    PAGE
    STAY
    SUPRVSNCANCELEDCHIME
    BAT NOT  READY PHONE
    TEST
    TAMPER   NO  AC
     
    OMNI-KP-US Fixed-Word Keypad
     
    XK108 LED Keypad 
     
     
     
     
    OMNI-LCD, OMNI-LCD-US, AND XK7LC KEYPADS 
     
    OMNI-LCD Alpha Keypad
     
     
    OMNI-LCD-US Alpha Keypad 
    STAY
    BYPASS
    INSTANT
    CODE 123
    456
    78
    9
    *0
    #
    XK-7LC_kypd 
    XK7LC Alpha Keypad 
      
    						
    							 
    – 9 – 
    System Reference (cont’d) 
     
    USER ID  ASSIGNED TO 
     
    1    (MASTER USER 1) 
    2    
    3    
    4    
    5    
    6   Duress** 
    * The Master User can add, change, or erase other User Codes. 
    ** If enabled, this User Code will transmit a duress signal to the central station. 
     
    MONITORING STATION INFORMATION 
    Account No.   
    Telephone No.   
     
     
     
     
     
     
      
    						
    							– 10 – 
    System Operation 
    You can arm or disarm the burglar portion of your security system.  
    Before you can arm the system, it must be “ready.”  If you have a 
    protected door open, or if someone is moving in view of a motion 
    detector, the system will not display “READY.” 
    The system is ready if the READY LED is lit and the display shows: 
    LCD Keypad: 
    SYSTEM READY 
      
    Fixed-Word Keypad: 
    READY LED lit 
     
     
    NOTE: If programmed by your installer, you may arm the system if a 
    delay or interior zone is faulted. However, faulted zones must be 
    restored before your exit time expires or an alarm or zone bypass will 
    result. Ask your installer if your system has this feature and, if so, if it 
    causes an alarm or zone bypass. 
    To Arm the System and Leave  
    Enter your User Code. 
    The ARMED LED goes on and the display shows: 
     
    LCD Keypad: 
    ON: AWAY 
      
    Fixed-Word Keypad: 
    ARMED LED lit 
     
     
    Exit through a door designated by your installer as an exit/entry door.  
    You must leave within the exit time programmed by your installer.  
    Refer to the reference sheet for the time that has been set for your 
    system.  
    						