N9942-2V2 4/04 Rev. A FBII Security System FBII Security SystemFBII Security System FBII Security System O OO O O OO O M MM M M MM M N NN N N NN N I II I I II I® - -- - - -- - 4 44 4 4 44 4 0 00 0 0 00 0 8 88 8 8 88 8 O OO O O OO O M MM M M MM M N NN N N NN N I II I I II I® - -- - - -- - 4 44 4 4 44 4 0 00 0 0 00 0 8 88 8 8 88 8 E EE E E EE E U UU U U UU U User Guide
– 3 – Table Of Contents QUICK REFERENCE ............................................................................................. 4 Arming the System ............................................................................................ 4 Disarming the System ....................................................................................... 4 Arm System/Stay Inside .................................................................................... 4 Arm System/Stay Inside/Instant Mode .............................................................. 4 Smoke Detector Reset ...................................................................................... 4 INTRODUCTION .................................................................................................... 6 SYSTEM REFERENCE ......................................................................................... 7 SYSTEM OPERATION ........................................................................................ 10 To Arm the System and Leave ....................................................................... 10 When the System is Not Ready ...................................................................... 11 To Arm the System and Stay Inside ............................................................... 11 To Arm the System In Instant Mode and Stay Inside ..................................... 12 To Arm the System In Instant Mode ............................................................... 13 To Bypass a Zone ........................................................................................... 13 To Unbypass a Zone ....................................................................................... 14 Disarming the System ..................................................................................... 14 USER CODES...................................................................................................... 16 Adding/Changing a User Code ....................................................................... 16 Deleting a User Code ...................................................................................... 16 PAGING FEATURE.............................................................................................. 17 Follow-Me Displays ......................................................................................... 17 Changing the Pager Follow-Me Phone Number ............................................. 17 MISCELLANEOUS COMMANDS ........................................................................ 19 TESTING THE SYSTEM ...................................................................................... 22 System Test .................................................................................................... 22 Battery Test ..................................................................................................... 22 RECOMMENDATIONS ON SMOKE DETECTORS ............................................ 23 EMERGENCY EVACUATION.............................................................................. 24 RADIO FREQUENCY EMISSIONS STATEMENTS.................................... 25 FEDERAL COMMUNICATIONS COMMISSION (FCC) PART 15 ....................... 25 TELEPHONE/MODEM INTERFACE STATEMENTS................................. 25 TELEPHONE OPERATIONAL PROBLEMS................................................. 26 O560 DECLARATION OF CONFORMITY............................................... 26 SYSTEM LIMITATIONS ....................................................................................... 27 GLOSSARY.......................................................................................................... 29
– 4 – Quick Reference Arming the System Check to make sure the system is ready — Green READY LED is lit. Enter your 4-digit User Code (or press the ARM button on your keyfob). The ARMED LED goes on. Exit through a door designated by your installer as an exit/entry door. Disarming the System Enter through door designated by your installer as an exit/entry door. Enter your 4-digit User Code (or press the DISARM button on your keyfob). The ARMED LED goes out. Arm System/Stay Inside Check to make sure the system is ready — Green READY LED is lit. Press STAY followed by your User Code. The ARMED and STAY LEDs light. You must disarm the system if you want to open the door or leave the premises after the exit time has passed. Arm System/Stay Inside/Instant Mode Check to make sure the system is ready — Green READY LED is lit. Press INSTANT thenSTAY followed by your User Code. The ARMED, INSTANT, and STAY LEDs are all lit. Smoke Detector Reset Enter your 4-digit User Code.
– 5 – Quick Reference (cont’d) The following table lists the “Quick Commands” available with this control. Keystroke Quick Command Keypads Description # 1 Quick Arm All keypads If system is ready, allows you to arm the system without requiring your User Code. Your User Code is always needed to disarm the system. # 2 Force Arm All keypads Allows you to arm the system even if some zones are faulted. These zones are automatically bypassed and are unprotected. [BYPASS] + Zone No. Quick Bypass All keypads Allows you to bypass a specific zone number. Must be enabled by your installer. # 3 Set Time All keypads Allows entry of the current system time (hours, minutes, month, day, year). # 4 Zone Directory LCD only Displays listing of zones in system. # 55 Display Firmware Version LCD only Displays version of your OMNI-408 firmware. # 56 Display Keyfob Battery Status All keypads Allows you to test battery status of your keyfob. Upon entry of this mode, press any button on the keyfob and the keypad will display if your battery is low. # 58 Change/View Pager Number All keypads Allows you to redirect pager output to a different pager number. Phone numbers are displayed only on LCD keypads. # 6 Display/Toggle Chime Mode All keypads Allows you to change the status of the chime function. # 7 Display Current Time LCD only Allows you to view the current system time. # 8 User Page Toggle All keypads Allows you to turn the pager mode on or off. Keypad displays the current system status.
– 6 – Introduction Congratulations on your decision to protect your home or business with the OMNI® -408 security system. You have chosen a reliable, state-of-the-art security system that is remarkably easy to operate. Representatives from your local security company, who can explain the specifics of your system, have professionally installed your system. The keypad is the input and display device for your security system. Your system can use either the OMNI-KP, OMNI-KP-US, OMNI-LCD, OMNI-LCD-US, XK7LC, or XK108 keypads. The OMNI-KP and OMNI-KP-US keypads display the system status with fixed words, the OMNI-LCD, OMNI-LCD-US, and XK7LC keypads display two lines of text, and the XK108 keypad displays the current zone status, including alarms, bypasses, and faults, using LEDs. Each condition causes the LEDs to operate differently. Throughout this guide, the following conventions are used to display the keystrokes required to perform functions. BYPASS Key labeled [BYPASS] INSTANT Key labeled [INSTANT] STAY Key labeled [STAY] CODE Key labeled [CODE] Enter your four-digit User Code. Please keep your guide in a convenient location so you can refer to it if needed.
– 7 – System Reference ZONE DESCRIPTION 1 2 3 4 5 6 7 8 ENTRY TIME 1 DOOR EXIT TIME* ENTRY TIME 2 DOOR * Exit time is the same for all designated entry/exit doors. The following SEND HELP ALERTS can be programmed into your system. Both keys must be pressed at the same time to activate the alert. The keys you press depend on which type of keypad you have. Your installer will show you how to activate these emergency keys. DESCRIPTION KEYS [#] and [*] [7] and [9] [1] and [3] See page 8 of this User Guide for pictures of the OMNI-KP,OMNI-KP-US, OMNI- LCD, OMNI-LCD-US, XK7LC, and XK108 keypads.
– 8 – System Reference (cont’d) OMNI-KP,OMNI-KP-US AND XK108 KEYPADS ALARMFIRE INSTANT BYPASS TRBL PAGE STAY SUPRVSNCANCELEDCHIME BAT NOT READY PHONE TEST TAMPER NO AC OMNI-KP Fixed-Word Keypad ALARMFIRE INSTANT BYPASS TRBL PAGE STAY SUPRVSNCANCELEDCHIME BAT NOT READY PHONE TEST TAMPER NO AC OMNI-KP-US Fixed-Word Keypad XK108 LED Keypad OMNI-LCD, OMNI-LCD-US, AND XK7LC KEYPADS OMNI-LCD Alpha Keypad OMNI-LCD-US Alpha Keypad STAY BYPASS INSTANT CODE 123 456 78 9 *0 # XK-7LC_kypd XK7LC Alpha Keypad
– 9 – System Reference (cont’d) USER ID ASSIGNED TO 1 (MASTER USER 1) 2 3 4 5 6 Duress** * The Master User can add, change, or erase other User Codes. ** If enabled, this User Code will transmit a duress signal to the central station. MONITORING STATION INFORMATION Account No. Telephone No.
– 10 – System Operation You can arm or disarm the burglar portion of your security system. Before you can arm the system, it must be “ready.” If you have a protected door open, or if someone is moving in view of a motion detector, the system will not display “READY.” The system is ready if the READY LED is lit and the display shows: LCD Keypad: SYSTEM READY Fixed-Word Keypad: READY LED lit NOTE: If programmed by your installer, you may arm the system if a delay or interior zone is faulted. However, faulted zones must be restored before your exit time expires or an alarm or zone bypass will result. Ask your installer if your system has this feature and, if so, if it causes an alarm or zone bypass. To Arm the System and Leave Enter your User Code. The ARMED LED goes on and the display shows: LCD Keypad: ON: AWAY Fixed-Word Keypad: ARMED LED lit Exit through a door designated by your installer as an exit/entry door. You must leave within the exit time programmed by your installer. Refer to the reference sheet for the time that has been set for your system.