Page 11
15 To temporarily raise or lower the temperature for the current period only. If you change your mind.WARMER COOLER TUE LEAVEPMSET PTRUN PROGRAM AHEAD BACK RUN PROGRAM WARMER COOLER SLEEP WAKELEAVE RETURN DAY Press and hold until the desired temperature is reached. The display will flash TEMPORARY until the next programmed time period starts. Press and release to cancel any of the temporary settings. Press and release the desired period key. Press and hold until the desired day schedule shows on the...
Page 12
17 18 OPERATING YOUR THERMOSTAT CANCELING PROGRAM SETTINGS The thermostat requires time and temperature settings in the WAKE period, but any of the other periods can be canceled. Weekday, Saturday and Sunday settings are canceled separately.Press and hold the desired period key until the time and temperature clear from the display (about 3 seconds). Press and release to return to normal operation.SLEEP LEAVE RETURN RUN PROGRAM MON TUE WED THU FRI ON HEAT LEAVE MON RETURNPM CHECKING THE PROGRAM TIMES AND...
Page 13
19 20 CHECKING THE CURRENT TEMPERATURE SETTING Press a single key to compare current room temperature to the setting at any time.PRESENT SETTINGPress and release. The display will show the current temperature setting for several seconds, then revert to the room temperature. ON HEATSET PT ACCSING EXTERNAL SYSTE OPERATING YOUR THERMOSTAT EXTERNAL ACCESS AND CONTROL OF THERMOSTAT The T8631 Communicating Chronotherm III Thermostat can be connected to a Honeywell TotalHome system for external access and...
Page 14
22 REMOVING THE THERMOSTAT 1 Loosen the two captive screws at the bottom corners of the case.2 Pull out the thermostat from the bottom.3 Lift the thermostat up and off the base. AUX. HEAT HEAT AUTOCOOLOFFO N A U T OF A N M5066 SYSTEM E M . H T .H E A TO F FONAUTOFAN M5013 C O O LEM. HT.AUX. HEAT SYSTEMPMRETURN MON HEAT ONSYSTEM M5062 R U N P R O G R A M T I M ET E M P E R A T U R E P R E S E N T S E T T I N G S K I P N E X T P E R I O D C H A N G E T O L A S T P E R I O D S E T P R E S E N T D A Y /...
Page 15
23 24 MAINTAINING YOUR THERMOSTAT REPLACING THE BATTERIES Your thermostat uses three AAA alkaline batteries. The display will flash REPL BAT when the batteries get low. You wonÕt have to reprogram the thermostat if you insert the new batteries within 20-30 seconds of taking out the old ones. To replace: nSet the system switch to OFF. nRemove the thermostat from the wall. See page 21. nLift the batteries out of the holder. nInsert the new batteries, making sure the positive (+) terminals all face toward...
Page 16
25 26 ADAPTIVE INTELLIGENT RECOVERYª M 168 ADAPTIVE INTELLIGENT RECOVERYªÑBREAK- THROUGH TECHNOLOGY SENSES TEMPERATURE MORE LIKE YOU DO Your new thermostat is so smart, itÕs almost human.n Your body perceives temperature from a variety of sources, not only from the air in the room, but also from your surroundingsÑwalls, windows and furnishings. n Human beings feel differences in temperature as slight as two degrees Fahrenheit. n Common household thermometers and standard thermostats sense only air...
Page 17
27 28 AM PMSUN MON TUE WED THU FRI SAT COOL ON HEAT ONWAKE LEAVE RETURN SLEEP TEMPORARY UNOCCUIPIED REPL BATSET PT AM PMSUN MON TUE WED THU FRI SAT COOL ON HEAT ONWAKE LEAVE RETURN SLEEP TEMPORARY UNOCCUIPIED REPL BATSET PT AM PMSUN MON TUE WED THU FRI SAT COOL ON HEAT ONWAKE LEAVE RETURN SLEEP TEMPORARY UNOCCUIPIED REPL BATSET PT AM PMSUN MON TUE WED THU FRI SAT COOL ON HEAT...
Page 18
SELECTING RECOVERY SETTING 29 30 Your T8631A Thermostat includes a screw on the back marked 2A, allowing for the Adaptive Intelligent Recov- eryª/Conventional Recovery choice. Your thermostat was shipped from the factory with the screw positioned for Adaptive Intelligent Recovery setting. Your installer may have left the screw in this position, or may have changed it to Conventional Recovery. Before programming, you must know which recovery method your thermostat has been set for. ¥ With the Adaptive...
Page 19
HEAT PUMP WITH SUPPLEMENTAL HEAT HEAT PUMPS ARE DIFFERENT (T8631R) nHeat pump systems usually have a supplemental, second stage heating system that operates only when necessary . The Honeywell Chronotherm III Thermostat for heat pumps is designed to minimize the more expensive second-stage operation, indicated by the green AUX light on the switching subbase. n With your Chronotherm III Thermostat, you will notice that your compressor operates continuously during the recovery period . This may appear to...
Page 20
33 34 ANSWERING COMMON QUESTIONS ABOUT THE CHRONOTHERM III THERMOSTAT 3. Why does the T8631 follow a schedule not programmed into the thermostat? When the s s is displayed, the thermostat is control- ling to the setting in your TotalHome system. 4. How many hours in advance of my WAKE time should the furnace come on? The time will vary, up to 24 minutes per degree Fahrenheit difference between the energy saving and comfort temperatures, depending on outside temperature and performance during the past...