Installation 42009636-005 R3 1 honeywell Chronotherm Parameters Optimisation Minimum ON Time AM-PM / 24hr Display Accessory Module Type RESET Time / Temperature Program Heat / Cool Operation Electric Heat Pump Exercise Cycle Rate Second Temperature Sensor Upper Temperature Limit Lower Temperature Limit Temperature Offset Pressure Offset (needed for Weatherstation accessory only) Proportional Band Width Return all Set-Up Features to Factory Settings Installer Set-Up Mode - Settings Table You must now press the PROG 2 key to enter the next sectionInstaller Set-Up Number / Abbreviation (Press + or - key to change) 1:0P 2:0t 3:Cl 4:At 5:rP 6:HC 7:Eh 8:PE 9:Cr 10:SS 11:UL 12:LL 13:tO 14:PO 15:Pb 16:FSDisplay 0 1 0 0 1 1 0 0 6 0 30 5 0 0 1.5 1 Factory Setting Description Optimisation disabled 1 minute minimum ON time 24 hr clock display No accessory module plugged in Time / Temperature profile set to factory default Changes to 0 when one of the time/temp profiles are changed Heating Operation Applications < 3A Pump Exercise Disabled 6 cycles per hour (cph) for gas boilers, zone valves and fan-coil No sensor fitted 30°C Upper Temp. Limit 5°C Lower Temp. Limit No offset No offset 1.5°C Proportional Band All settings held are the factory defaults. Changes to 0 when one of the parameter values are changed Display/Setting 1 2 to 5 1 1, 2 0 1 0 1 1 3, 9, 12 1, 2 21 to 29 6 to 16 -3 to +3 -99 to +99 1.6 to 3.0 0 1 Optional Setting Description Optimisation enabled 2 - 2 minutes 3 - 3 minutes 4 - 4 minutes 5 - 5 minutes 12 hr AM / PM clock display 1 - Auto Time Setting Module 2 - Weatherstation Module Time / Temperature are as programmed To restore the factory profile set to 1 Cooling Operation Applications 3 - 8A Pump Exercise Enabled 3 - 3 cph 9 - 9cph 12 - 12 cph 1 - Outside Temperature Sensor fitted 2 -Remote Temp. Sensor fitted 21°C to 29°C adjustment in 1°C steps 6°C to 16°C adjustment in 1°C steps -3°C to +3°C adjustment in 0.1°C steps -99 mbar to +99 mbar adjustment in 1 mbar steps 1.6°C to 3.0°C adjustment in 0.1°C steps Settings are as modified above To restore the factory profile set to 1Installer Set-Up Category (Press keys PROG 1 or 2 to select) 1 2 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 Notes 1) When the Installer Set-Up Mode is initiated, only Category 1 ( 1) Set-Up Features are accessible. Category 2 ( 2) Set-Up Features are accessed by pressing the PROG. 2 key. 2) Remember to always press the INFO button to confirm that you want to store your new Installer Set-Up setting. 3) To exit the Installer Set-Up Mode move the slider to the AUTOmatic or MANual position. 2 34 a4 b 4 c5 6 1.0-2.5mm² honeywell Home Comfort & Systems Honeywell Control Systems Ltd. Newhouse Industrial Estate Motherwell, ML1 5SB Scotlandhttp://europe.hbc.honeywell.com 3mm max.3mm max. This product has been designed with your environment in mind! Please respect this by disposing of all packaging, used parts and eventually the product itself in an environ- mentally friendly manner.
89 1011 You have now installed the Chronotherm. For gas boiler applications, the factory system settings will not need to be changed (for other applications see below). You can now use the USER GUIDE to program the unit and demonstrate how it works to the homeowner. Special Features Optimisation (Variable Start Time) AM-PM/ 24hr Display Pump Exercise Upper Temperature Limit Lower Temperature Limit Temperature Offset Proportional Band WidthWhat do I need to do if I wish this feature? Set parameter n.1 in the installer set-up mode to 1 Set parameter n.3 in the installer set-up mode to 1 Set parameter n.8 in the installer set-up mode to 1 Set parameter n.11 in the installer set-up mode to the desired limit Set parameter n.12 in the installer set-up mode to the desired limit Set parameter n.13 in the installer set-up mode to the desired offset value. Set parameter n.15 in the installer set-up mode to the desired valueDescription The Chronotherm will adjust the start time in the morning/afternoon so the desired temperature is reached by the start of the program period e.g. Time 7:00, Temp 21°C. The system will restrict the start time to a max of 3 hours The end user can have a different clock format display The circulating pump on hydronic systems can be exercised once a day for 1 minute at mid-day. Useful to prevent the pump from sticking after the summer The normal upper temperature limit of 30°C can be reduced down to 21°C to save the homeowner energy. The normal lower temperature limit of 5°C can be increased up to 16°C to protect the inhabitants from cold. Useful if the inhabitants include the elderly, children or disabled If the Chronotherm is located in a particularly hot/cold location and cannot be moved because of wiring then the measured/displayed temperature can be adjusted by +/- 3°C. Useful if the homeowner wants the reading to match another appliance temperature display Can be adjusted up to 3°C (default is 1.5°C) to provide better temperature control (less overshoot). Useful for: a. Well insulated homes with over-sized heating systems b. Air systems with fast response Optional Accessories Outside Temperature Sensor Remote Temperature Sensor Automatic Time Setting (ATS) ModuleWhat do I need to do if I wish this feature? 1. Fit the sensor (instructions included in the sensor package) 2. Set parameter n. 10 in the installer set-up mode to 1 1. Fit the sensor (instructions included in the sensor package) 2. Set parameter n. 10 in the installer set-up mode to 2 1. Fit the ATS module 2. Set parameter n. 4 in the installer set-up mode to 1 Description An Outside Temperature Sensor can be fitted to your CM67 to allow the homeowner to display the outside temperature on the Chronotherm display by using the INFO button. A Remote Temperature Sensor can be fitted to your CM67 to allow the Chronotherm to control the temperature from another room e.g. in a commercial premises where the public may adjust keys. The ATS module picks up a time signal daily from a European transmitter, so you never need to set or adjust the time. Move the slider to the OFF position. Press and hold INFO button and press PROG 3,4 together. Press TEMP or to change factory setting. The display will flash indicating that a change has been made.Press INFO button to confirm the change is ok. The display will stop flashing indicating that the new value has been stored. Adjust other settings using the Installer Set- Up Mode - Settings Table on the next page. To exit the Installer Set-Up Mode move the slider to the AUTOmatic or MANual position. 12 34 56 7 7 1 Installer Set-Up Number (Press + or - to change) e.g. 1 = OptimisationAbbreviated Set-Up Description e.g. 0P = Optimisation Factory Setting or New Choice (Press Temp or to change) e.g. 0 = Optimisation disabled e.g. 1 = Optimisation enabled Installer Set-Up Mode Selected Category 1 Installer Set-Ups 1 Once you have inserted the battery cartridge, after a pause the unit will display information. If this does not happen or the display shows the symbol please refer to the ‘trouble shooting’ section in the CM67 user guide. What else will the Chronotherm do? •Cover Specific Applications •Perform Special Features •Support Optional AccessoriesInstaller Set-Up Mode 1 Press + or - to go to the next parameter and follow steps 3 & 4 to make changes. 1 Specific Application Heating Air- conditioningWhat do I need to change? Note: a. To change Cycle/Hour, please go to parameter n. 9 in the installer set-up mode. b. To change Minimum ON Time, please go to parameter n. 2 in the installer set-up mode No action required 1. Set Minimum ON Time to 4 minutes. 2. Set Cycle/Hour to 3. Set Cycle/Hour to 12. No action required 1. Configure the Chronotherm for electric heating (set parameter n.7 in the installer set up mode to 1) 2. Set Cycle/Hour to 12 1. For cooling application only, set the Chronotherm to cooling (set parameter n.6 in the installer set-up mode to 0) 2. For heat/cool application, set the Chronotherm accordingly to required mode of operation by changing parameter n.6 in the installer set-up mode. winter = heating summer = cooling Explain to the end-user how to implement the change-over and ensure that the appropriate time and temperature profile is established for heating and cooling 1. Set Minimum ON Time to 4 minutes. 2. Set Cycle/Hour to 3. No action required Setting Cycle/ Minimum Hour ON Time 61 34 12 1 61 12 1 34 61 Gas Boilers (