    							Installation
    42009636-005 R3
    1
    honeywell
    Chronotherm
    Parameters
    Optimisation
    Minimum ON Time
    AM-PM / 24hr Display
    Accessory Module Type
    RESET Time / Temperature
    Program
    Heat / Cool Operation
    Electric Heat
    Pump Exercise
    Cycle Rate
    Second Temperature
    Sensor
    Upper Temperature Limit
    Lower Temperature  Limit
    Temperature Offset
    Pressure Offset
    (needed for Weatherstation
    accessory only)
    Proportional Band Width
    Return all Set-Up Features
    to Factory Settings
    Installer Set-Up Mode - Settings Table
    You must now press the PROG 2 key to enter the next sectionInstaller Set-Up
    Number /
    Abbreviation
    (Press  + or -
    key to change)
    1:0P
    2:0t
    3:Cl
    4:At
    5:rP
    6:HC
    7:Eh
    8:PE
    9:Cr
    10:SS
    11:UL
    12:LL
    13:tO
    14:PO
    15:Pb
    16:FSDisplay
    0
    1
    0
    0
    1
    1
    0
    0
    6
    0
    30
    5
    0
    0
    1.5
    1 Factory Setting
    Description
    Optimisation disabled
    1 minute minimum ON time
    24 hr clock display
    No accessory module
    plugged in
    Time / Temperature profile
    set to factory default
    Changes to 0 when one of the
    time/temp profiles are changed
    Heating Operation
    Applications < 3A
    Pump Exercise Disabled
    6 cycles per hour (cph) for
    gas boilers, zone valves and
    fan-coil
    No sensor fitted
    30°C Upper Temp. Limit
    5°C Lower Temp. Limit
    No offset
    No offset
    1.5°C Proportional Band
    All settings held are the
    factory defaults. Changes to
    0 when one of the parameter
    values are changed
    Display/Setting
    1
    2 to 5
    1
    1, 2
    0
    1
    0
    1
    1
    3, 9, 12
    1, 2
    21 to 29
    6 to 16
    -3 to +3
    -99 to +99
    1.6 to 3.0
    0
    1 Optional Setting
    Description
    Optimisation enabled
    2 - 2 minutes
    3 - 3 minutes
    4 - 4 minutes
    5 - 5 minutes
    12 hr AM / PM clock display
    1 - Auto Time Setting Module
    2 - Weatherstation Module
    Time / Temperature are as
    programmed
    To restore the factory profile
    set to 1
    Cooling Operation
    Applications 3 - 8A
    Pump Exercise Enabled
    3 - 3 cph
    9 - 9cph
    12 - 12 cph
    1 - Outside Temperature
    Sensor fitted
    2 -Remote Temp. Sensor fitted
    21°C to 29°C adjustment in
    1°C steps
    6°C to 16°C adjustment in 1°C
    steps
    -3°C to +3°C adjustment in
    0.1°C steps
    -99 mbar  to +99 mbar
    adjustment in 1 mbar steps
    1.6°C to 3.0°C adjustment in
    0.1°C steps
    Settings are as modified
    above
    To restore the factory profile
    set to 1Installer Set-Up
    Category
    (Press keys PROG 1
    or 2 to select)
     
     1  2
    1
    1
    1
    1
    1
    2
    2
    2
    2
    2
    2
    2
    2
    2
    2
    2
    Notes
    1) When the Installer Set-Up Mode is initiated, only Category 1  ( 1) Set-Up Features
    are accessible.
    Category 2 (
     2) Set-Up Features are accessed by pressing the PROG. 2 key.
    2) Remember to always press the INFO 
     button to confirm that you want to store your new
    Installer Set-Up setting.
    3) To exit the Installer Set-Up Mode move the slider to the AUTOmatic or MANual position.
    2
    34  a4  b
    4  c5
    6
    1.0-2.5mm²
    honeywell
    Home Comfort & Systems
    Honeywell Control Systems Ltd.
    Newhouse Industrial Estate
    Motherwell, ML1 5SB
    Scotlandhttp://europe.hbc.honeywell.com
    3mm
    max.3mm
    max.
    This product has been designed with your
    environment in mind! Please respect this by
    disposing of all packaging, used parts and
    eventually the product itself in an environ-
    mentally friendly manner. 
    						
    							89
    1011
    You have now installed the Chronotherm.  For gas boiler applications, the factory system
    settings will not need to be changed (for other applications see below). You can now use
    the USER GUIDE to program the unit and demonstrate how it works to the homeowner.
    Special Features
    Optimisation (Variable
    Start Time)
    AM-PM/ 24hr Display
    Pump Exercise
    Upper Temperature Limit
    Lower Temperature Limit
    Temperature Offset
    Proportional Band WidthWhat do I need to do if I wish
    this feature?
    Set parameter n.1 in the installer
    set-up mode to 1
    Set parameter n.3 in the installer
    set-up mode to 1
    Set parameter n.8 in the installer
    set-up mode to 1
    Set parameter n.11 in the installer
    set-up mode to the desired limit
    Set parameter n.12 in the installer
    set-up mode to the desired limit
    Set parameter n.13 in the installer
    set-up mode to the desired offset
    value.
    Set parameter n.15 in the installer
    set-up mode to the desired valueDescription
    The Chronotherm will adjust the start time in the morning/afternoon so the
    desired temperature is reached by the start of the program period e.g. Time
    7:00, Temp 21°C. The system will restrict the start time to a max of 3 hours
    The end user can have a different clock format display
    The circulating pump on hydronic systems can be exercised once a day for 1
    minute at mid-day. Useful to prevent the pump from sticking after the summer
    The normal upper temperature limit of 30°C can be reduced down to 21°C to
    save the homeowner energy.
    The normal lower temperature limit of 5°C can be increased up to 16°C to
    protect the inhabitants from cold. Useful if the inhabitants include the elderly,
    children or disabled
    If the Chronotherm is located in a particularly hot/cold location and cannot
    be moved because of wiring then the measured/displayed temperature can
    be adjusted by +/- 3°C. Useful if the homeowner wants the reading to match
    another appliance temperature display
    Can be adjusted up to 3°C (default is 1.5°C) to provide better temperature
    control (less overshoot). Useful for:
    a.  Well insulated homes with over-sized heating systems
    b.  Air systems with fast response
    Optional
    Accessories
    Outside Temperature
    Sensor
    Remote Temperature
    Sensor
    Automatic Time  Setting
    (ATS) ModuleWhat do I need to do if I wish
    this feature?
    1. Fit the sensor (instructions
    included in the sensor package)
    2. Set parameter n. 10 in the
    installer set-up mode to 1
    1. Fit the sensor (instructions
    included in the sensor package)
    2. Set parameter n. 10 in the
    installer set-up mode to 2
    1. Fit the ATS module
    2. Set parameter n. 4 in the
    installer set-up mode to 1
    Description
    An Outside Temperature Sensor can be fitted to your CM67 to allow the
    homeowner to display the outside temperature on the Chronotherm display
    by using the INFO 
     button.
    A Remote Temperature Sensor can be fitted to your CM67 to allow the
    Chronotherm to control the temperature from another room e.g. in a
    commercial premises where the public may adjust keys.
    The ATS module picks up a time signal daily from a European transmitter, so
    you never need to set or adjust the time.
    Move the slider to
    the OFF position.
    Press and hold
    INFO 
     button and
    press PROG 3,4
    together.
    Press TEMP  or  to change factory setting.
    The display will flash indicating that a change has
    been made.Press INFO  button to confirm the change is ok.
    The display will stop flashing indicating that the new
    value has been stored.
    Adjust other settings using the Installer Set-
    Up Mode - Settings Table on the next page.
    To exit the Installer Set-Up Mode move the
    slider to the AUTOmatic or MANual position.
    12
    34
    56
    7
    7
    1
    Installer Set-Up Number
    (Press  + or - to change)
    e.g. 1 = OptimisationAbbreviated Set-Up Description
    e.g. 
    0P = Optimisation
    Factory Setting or New Choice
    (Press Temp 
     or  to change)
    e.g. 0 = Optimisation disabled
    e.g. 1 = Optimisation enabled Installer Set-Up Mode
    Selected
    Category 1 Installer Set-Ups
    1
    Once you have inserted the battery cartridge,
    after a pause the unit will display information.
    If this does not happen or the display shows
    the 
     symbol please refer to the ‘trouble
    shooting’ section in the CM67 user guide.
    What else will the Chronotherm do?
    •Cover Specific Applications
    •Perform Special Features
    •Support Optional AccessoriesInstaller Set-Up Mode
    1
    Press  + or - to go to the next parameter and follow
    steps 3 & 4 to make changes.
    1
    Specific Application
    Heating
    Air-
    conditioningWhat do I need to change?
    Note:
    a. To change Cycle/Hour, please go to parameter n. 9 in the installer
    set-up mode.
    b. To change Minimum ON Time, please go to parameter n. 2 in the
    installer set-up mode
    No action required
    1. Set Minimum ON Time to 4 minutes.
    2. Set Cycle/Hour to 3.
    Set Cycle/Hour to 12.
    No action required
    1. Configure the Chronotherm for electric heating (set parameter n.7
    in the installer set up mode to 1)
    2. Set Cycle/Hour to 12
    1.  For cooling application only, set the Chronotherm to cooling (set
    parameter n.6 in the installer set-up mode to 0)
    2.  For heat/cool application, set the Chronotherm accordingly to
    required mode of operation by changing parameter n.6 in the
    installer set-up mode.
    winter = heating    summer = cooling
    Explain to the end-user how to implement the change-over and ensure that the
    appropriate time and temperature profile is established for heating and cooling
    1.  Set Minimum ON Time to 4 minutes.
    2.  Set Cycle/Hour to 3.
    No action required
    Setting
    Cycle/ Minimum
    Hour ON Time
    61
    34
    12 1
    61
    12 1
    34
    61 Gas Boilers
    (
    						