    ACS-8-System
    Access Control
    The ACS-8 is an access control system which is modular
    in construction and highly autonomous.
    A particularly noteworthy performance feature is the flex-
    ible and  freely-selectable installation technology. This
    enables conventional connection of up to two separate
    doors or one door with an internal and external reader.
    An expansion option of up to max. 8 doors exists via the
    communication module utilising core-conserving RS-485
    bus technology.
    Standard features include two controllable RS-485 inter-
    face drivers integrated in the communication module.
    The firmware is completely upgradable. Time-consuming
    EPROM changing during function expansion is thus 
    a thing of the past. New program components and 
    expansions can be imported in the central control units
    via 
    the access control software (e.g. MultiAccess for 
    Windows
    or IQ MultiAccess). Up to 8 ACS-8 units can be operated via an external 
    interface converter, up to 32 units via an external bus con-
    troller. Access control rights 
    are set up and administered
    via the access control software
    (e.g. MultiAccess for Wind-
    ows or IQ MultiAccess).
    The ACS-8 contains decision rights for door release and
    control.
    Terminals can be integrated directly in existing ethernet
    networks (LANs) through selective configuration with an
    ethernet card (026840.29).
    A maximum expansion of 999 doors per location can be
    achieved through the utilisation of several bus controllers
    and / or in the ethernet network.
    • Intelligent access control terminal up to 4 doors  (4 doors strikes, 2 readers/keypads directly con-
    nectable, 2 futher readers/keypads via RS-485
    module bus, expandable up to max. 8 doors via
    RS-485 module bus)
    • Upgradable program memory  and dynamic memory administration
    • Battery-buffered memory  (0.5 MB, expandable up to 3.5 MB) 
    • Approx. max. 65 500 identification cards*
    • Approx. max. 512 room/time zones*
    • National holiday and leave calendar
    • Booking buffer for max. 65000 events*
    • Clock with date and automatic  daylight saving time/normal time changeover
    • BSI - listing (including all components  connectable to the ACS-8)
    • VdS approval
    Performance features at a glance
    Connection of:
    • 2 readers with clock/data interface and 2 keypads with 2-wire interface possible
    •
    4 relay outputs (e.g.: door strike, flash lamp, etc.)
    • 3 semiconductor outputs  (e.g.: threat, watchdog, etc.)
    • User-friendly and flexible event control  via inputs and relays
    • Macro-control (IACP control, lift control, etc.)
    • Anti passpack, barring repeated entry, threat code, counter control
    •
    Lock function with reciprocal door state influence
    * Values depend on the memory configuration and  parameterising of dynamic memory administration. 
    						
    							
    ACS-8 planning example
    3 
    						
    							
    5
    ACS-8 planning example 
    						
    							
    026575 Basic ACS-8 system with freely-selectable power supply
    unit integration
    As for 230 V version, but without power supply unit.One of the following power 
    supply/charger units can be utilised, depending on current requirement:
    012168 = 80 Ah/continuous current consumption: 3,5 A
    012170 = 130 Ah/continuous current consumption: 5,0 A
    Technical data
    Rated operating voltage 12 DC
    Rated operating voltage range 10 V DC to 15 V DC
    Current consumption without periphery max. 150 mA
    Operating temperature range -5°C to +55°C
    Storage temperature range -25°C to +70°C
    Environmental protection class acc. to VdSII
    Colour Grey-white (similar to RAL 9002)
    Housing / Dimensions (W x H x D) Sheet steel / 350 x 280 x 100 mm
    026596  1 MB RAM memory card
    026597 2 MB RAM memory card
    026598 3 MB RAM memory card
    
    026580 Basic ACS-8 system, 12 V DC
    Technical data
    Rated operating voltage 12 V DC
    Rated operating voltage range 10 V DC to 15 V DC
    Current consumption without periphery max. 150 mA
    Operating temperature range -5°C to +55°C
    Storage temperature range -25°C to +70°C
    Environmental protection class acc. to VdSII
    Colour Grey-white (similar to RAL 9002)
    Housing / Dimensions (W x H x D) Sheet steel / 250 x 210 x 100 mm
    
    Power supply unit selection 
    depends on the connected 
    consumers.
    
    Includes 010 690.02 
    power supply/charger unit 
    
    Memory expansions
    026585 Basic ACS-8 system, 230 V AC(As for 12 V version)
    Technical data
    Rated operating voltage 230 V AC
    Rated operating voltage range 230 V AC -15% +10%
    Continuous current consumption 1,4 A
    Battery space1 x 018003.10 (3,5 Ah) or 2 x 018002.10 (2,0 Ah)
    Colour Grey-white (similar to RAL 9002)
    Housing / Dimensions (W x H x D) Sheet steel / 350 x 280 x 100 mm
    
    026587 Communication module
    The ACS-8 communicates via the communication module with the connected RS-485
    users. Standard features include 2 separated RS-485 interface drivers integrated in the
    communication module. A maximum of 2 communication modules can be integrated
    per ACS-8. A maximum of 32 users can be connected simultaneously per ACS-8.
    Technical data
    Current consumption max. 150 mA
    Function expansion
    
    026590 Input module, RS-485 with potential separation
    Technical data
    Digital inputs 4 x with potential separation
    Current consumption max. 140 mA
    Rated operating voltage range 9 V DC to 15 V DC
    Dimensions (W x H x D) 118 x 118 x 30 mm
    Module BUS users / RS-485 modules
    6 
    						
    							
    026591 Output module, RS-485 with potential separation
    Technical data
    Relays 4 x 24 V DC/1 A
    Current consumption max. 250 mA
    Rated operating voltage range 9,5 V DC to 15 V DC
    Dimensions (W x H x D) 118 x 118 x 30 mm
    
    026592 Input/Output module, RS-485 with potential separation
    Technical data
    Differential inputs 2 x erasable
    Digital inputs 2 x with potential separation
    Relays 2 x 24 V DC /2 A
    Current consumption max. 230 mA
    Rated operating voltage range 9,5 V DC to 15 V DC
    Dimensions (W x H x D) 118 x 118 x 30 mm
    
    026593 Door module, 12 V DC, RS-485 with potential separation
    The complete door periphery is wired to the door module. The door module is a module
    bus user and communicates with the ACS-8 via an integrated RS 485 interface.
    The ACS-8 contains the access control rights and makes decisions. The number of doors
    to control by a door module depends on the access control software used.
    MultiAccess for Windows: 1 door; IQ MultiAccess: 2 doors.
    The following components can be connected simultaneously to the door module:
    - two clock/data readers - a monitoring contact
    - two 2-wire keypads - a tamper switch
    - an opening contact - a door relay
    - ta bolt switching contact - an alarm relay
    - a glass breakage contact with reset - a tamper relay
    - a door release push-button
    (If 2 doors are controlled by a door module, the number of inputs and outputs left for 
    individual use reduces as they are required as monitoring contact, door strike relay and
    door strike key for the second door.)
    Technical data
    Rated operating voltage 12 V DC
    Rated operating voltage range 10 V to 15 V DC
    Current consumption in no-load operation without ext. user 200 mA
    Operating temperature range -5°C to +55°C
    Storage temperature range -25°C to +70°C
    Environmental protection class acc. to VdS II
    Colour Grey-white (similar to RAL 9002)
    Housing / Dimensions (W x H x D) Plastic / 250 x 210 x 100 mm
    
    026595 Potential separation module, RS-485
    A maximum of 4 modules without an intrinsic RS 485 bus with potential separationcan be
    connected to the module. Recommended when using external power supply units.
    Connectable modules are: 027555 and all readers and keypads with RS 485 and control lead.
    Technical data
    Current consumption max. 140 mA
    Rated operating voltage range 10V DC to 15 V DC
    Dimensions (W x H x D) 118 x 118 x 30 mm
    
    026594 Door module, 230 V AC, RS-485 with potential separation
    As for 12 V version, but with 230 V power supply unit.
    Technical data
    Rated operating voltage 230 V AC
    Rated operating voltage range 230 V AC -15% to +10%
    Current consumption in no-load operation without ext. user 65 mA
    Operating temperature range -5°C to +55°C
    Storage temperature range -25°C to +70°C
    Environmental protection class acc. to VdS II
    Colour Grey-white (similar to RAL 9002)
    Battery space1 x 018002.10 (2,0 Ah)
    Housing / Dimensions (W x H x D) Plastic / Plastic250 x 210 x 100 mm
    
    Power supply unit with battery
    charging circuit
    7 
    						
    							
    Honeywell Security Group
    Novar GmbH
    Joh.-Mauthe-Str. 14 · D -72458 Albstadt
    Phone + 49 (0) 74 31/ 801- 0 · Fax 801-12 20
    www.honeywell.com/security/de
    [email protected]
    04. 2010 · Subject to change without notice.
    ©2010 Honeywell International Inc.
    Central control unit versions
    026580 Basic ACS -8 system, 12 V DC
    approval Z 105009, class C
    026585 Basic ACS -8 system, 230 V AC (includes 010690.02 power supply/charger unit)
    approval Z 105009, class C
    026575 Basic ACS -8 system with freely-selectable power supply unit integration 
    (power supply unit selection depends on the 
    connected consumers, VdS only with power 
    supply units approved by VdS)
    approval Z 105009, class C
    026587 Communication module (required for controlling more than 2 doors)
    Item no. Description Item no. Description
    Order data
    Module bus users/ RS-485 modules
    026590 Input module, RS-485 with potential 
    separation
    026591 Output module, RS-485 with potential  separation
    026592 Input/Output module, RS-485 with potential separation
    026595 Potential seperation module, RS-485
    026593 Door module, 12, V DC, RS-485 with potential separation
    026594 Door module, 230 V AC, RS-485 with potential separation
    •4 digital inputs 
    (e.g.: door strike push-button,
    monitoring contact, etc.)
    •8 differential detector groups 
    (e.g.: magnetic contact, glass breakage sensor, etc.)
    •Integrated tamper contact
    •Optional host interfaces 
    (RS-485, RS-232, 10/100 Mbit/s fast ethernet,
    Current Loop)
    •Variable door release, monitoring and alarm times
    •Automatic function control via time zones 
    (e.g.: door release, etc.)
    Additional performance features
    •Special relay function for real-time release
    for rescue route integration
    •RS-485 module bus (optional)
    •Flexible power supply unit configuration,
    depending on power requirement
    •12 V DC emergency power supply,
    depending on power supply unit configuration 
    and power requirement
    •VdS-approval Z 105009, class C
    •Support of analog modems and ISDN terminal
    adapters
    •Direct modem connection without additional card
    • RS-485 magnetic card reader
    • RS-485 Legic reader
    • RS-485 mifare reader
    • RS-485 Esser reader contactless
    • RS-485 keypad
    • RS-485 Fingerkey
    • RS-485  12 V  version / 230 V  version  door  module
    The following components can be connected to the communication module
    • RS-485 input module
    • RS-485 output module
    • RS-485 input/output module
    •
    Biometrics: Fingerkey and/or integration of bio-
    metrical systems via RS-485 module bus
    •Arming/disarming of an intrusion detection system
    via AC-readers to be realized using inputs/outputs
    and macro programming in IQ MultiAccess
    Accessories
    026692 RS-485 interface (5-wire)  without potential separation
    026693 RS-485 interface (5-wire) with potential separation
    026840.03 Asynchronous RS-232 host interface
    026840.16 Current Loop interface 026840.29 10 /100 MBit/s ethernet host interface
    018002.10 Rechargeable battery 
    12 V DC / 2.0 Ah
    018003.10 Rechargeable battery 12 V DC / 3.5 Ah
    012168 Power supply/charging unit 80 Ah/permanent 
    current drain: 3,5 A
    012170 Power supply/charging unit 130 Ah/permanent  current drain: 5,0 A 
    						