ACS-8-System Access Control The ACS-8 is an access control system which is modular in construction and highly autonomous. A particularly noteworthy performance feature is the flex- ible and freely-selectable installation technology. This enables conventional connection of up to two separate doors or one door with an internal and external reader. An expansion option of up to max. 8 doors exists via the communication module utilising core-conserving RS-485 bus technology. Standard features include two controllable RS-485 inter- face drivers integrated in the communication module. The firmware is completely upgradable. Time-consuming EPROM changing during function expansion is thus a thing of the past. New program components and expansions can be imported in the central control units via the access control software (e.g. MultiAccess for Windows or IQ MultiAccess). Up to 8 ACS-8 units can be operated via an external interface converter, up to 32 units via an external bus con- troller. Access control rights are set up and administered via the access control software (e.g. MultiAccess for Wind- ows or IQ MultiAccess). The ACS-8 contains decision rights for door release and control. Terminals can be integrated directly in existing ethernet networks (LANs) through selective configuration with an ethernet card (026840.29). A maximum expansion of 999 doors per location can be achieved through the utilisation of several bus controllers and / or in the ethernet network. • Intelligent access control terminal up to 4 doors (4 doors strikes, 2 readers/keypads directly con- nectable, 2 futher readers/keypads via RS-485 module bus, expandable up to max. 8 doors via RS-485 module bus) • Upgradable program memory and dynamic memory administration • Battery-buffered memory (0.5 MB, expandable up to 3.5 MB) • Approx. max. 65 500 identification cards* • Approx. max. 512 room/time zones* • National holiday and leave calendar • Booking buffer for max. 65000 events* • Clock with date and automatic daylight saving time/normal time changeover • BSI - listing (including all components connectable to the ACS-8) • VdS approval Performance features at a glance Connection of: • 2 readers with clock/data interface and 2 keypads with 2-wire interface possible • 4 relay outputs (e.g.: door strike, flash lamp, etc.) • 3 semiconductor outputs (e.g.: threat, watchdog, etc.) • User-friendly and flexible event control via inputs and relays • Macro-control (IACP control, lift control, etc.) • Anti passpack, barring repeated entry, threat code, counter control • Lock function with reciprocal door state influence * Values depend on the memory configuration and parameterising of dynamic memory administration.
026575 Basic ACS-8 system with freely-selectable power supply unit integration As for 230 V version, but without power supply unit.One of the following power supply/charger units can be utilised, depending on current requirement: 012168 = 80 Ah/continuous current consumption: 3,5 A 012170 = 130 Ah/continuous current consumption: 5,0 A Technical data Rated operating voltage 12 DC Rated operating voltage range 10 V DC to 15 V DC Current consumption without periphery max. 150 mA Operating temperature range -5°C to +55°C Storage temperature range -25°C to +70°C Environmental protection class acc. to VdSII Colour Grey-white (similar to RAL 9002) Housing / Dimensions (W x H x D) Sheet steel / 350 x 280 x 100 mm 026596 1 MB RAM memory card 026597 2 MB RAM memory card 026598 3 MB RAM memory card 026580 Basic ACS-8 system, 12 V DC Technical data Rated operating voltage 12 V DC Rated operating voltage range 10 V DC to 15 V DC Current consumption without periphery max. 150 mA Operating temperature range -5°C to +55°C Storage temperature range -25°C to +70°C Environmental protection class acc. to VdSII Colour Grey-white (similar to RAL 9002) Housing / Dimensions (W x H x D) Sheet steel / 250 x 210 x 100 mm Power supply unit selection depends on the connected consumers. Includes 010 690.02 power supply/charger unit Memory expansions 026585 Basic ACS-8 system, 230 V AC(As for 12 V version) Technical data Rated operating voltage 230 V AC Rated operating voltage range 230 V AC -15% +10% Continuous current consumption 1,4 A Battery space1 x 018003.10 (3,5 Ah) or 2 x 018002.10 (2,0 Ah) Colour Grey-white (similar to RAL 9002) Housing / Dimensions (W x H x D) Sheet steel / 350 x 280 x 100 mm 026587 Communication module The ACS-8 communicates via the communication module with the connected RS-485 users. Standard features include 2 separated RS-485 interface drivers integrated in the communication module. A maximum of 2 communication modules can be integrated per ACS-8. A maximum of 32 users can be connected simultaneously per ACS-8. Technical data Current consumption max. 150 mA Function expansion 026590 Input module, RS-485 with potential separation Technical data Digital inputs 4 x with potential separation Current consumption max. 140 mA Rated operating voltage range 9 V DC to 15 V DC Dimensions (W x H x D) 118 x 118 x 30 mm Module BUS users / RS-485 modules 6
026591 Output module, RS-485 with potential separation Technical data Relays 4 x 24 V DC/1 A Current consumption max. 250 mA Rated operating voltage range 9,5 V DC to 15 V DC Dimensions (W x H x D) 118 x 118 x 30 mm 026592 Input/Output module, RS-485 with potential separation Technical data Differential inputs 2 x erasable Digital inputs 2 x with potential separation Relays 2 x 24 V DC /2 A Current consumption max. 230 mA Rated operating voltage range 9,5 V DC to 15 V DC Dimensions (W x H x D) 118 x 118 x 30 mm 026593 Door module, 12 V DC, RS-485 with potential separation The complete door periphery is wired to the door module. The door module is a module bus user and communicates with the ACS-8 via an integrated RS 485 interface. The ACS-8 contains the access control rights and makes decisions. The number of doors to control by a door module depends on the access control software used. MultiAccess for Windows: 1 door; IQ MultiAccess: 2 doors. The following components can be connected simultaneously to the door module: - two clock/data readers - a monitoring contact - two 2-wire keypads - a tamper switch - an opening contact - a door relay - ta bolt switching contact - an alarm relay - a glass breakage contact with reset - a tamper relay - a door release push-button (If 2 doors are controlled by a door module, the number of inputs and outputs left for individual use reduces as they are required as monitoring contact, door strike relay and door strike key for the second door.) Technical data Rated operating voltage 12 V DC Rated operating voltage range 10 V to 15 V DC Current consumption in no-load operation without ext. user 200 mA Operating temperature range -5°C to +55°C Storage temperature range -25°C to +70°C Environmental protection class acc. to VdS II Colour Grey-white (similar to RAL 9002) Housing / Dimensions (W x H x D) Plastic / 250 x 210 x 100 mm 026595 Potential separation module, RS-485 A maximum of 4 modules without an intrinsic RS 485 bus with potential separationcan be connected to the module. Recommended when using external power supply units. Connectable modules are: 027555 and all readers and keypads with RS 485 and control lead. Technical data Current consumption max. 140 mA Rated operating voltage range 10V DC to 15 V DC Dimensions (W x H x D) 118 x 118 x 30 mm 026594 Door module, 230 V AC, RS-485 with potential separation As for 12 V version, but with 230 V power supply unit. Technical data Rated operating voltage 230 V AC Rated operating voltage range 230 V AC -15% to +10% Current consumption in no-load operation without ext. user 65 mA Operating temperature range -5°C to +55°C Storage temperature range -25°C to +70°C Environmental protection class acc. to VdS II Colour Grey-white (similar to RAL 9002) Battery space1 x 018002.10 (2,0 Ah) Housing / Dimensions (W x H x D) Plastic / Plastic250 x 210 x 100 mm Power supply unit with battery charging circuit 7
Honeywell Security Group Novar GmbH Joh.-Mauthe-Str. 14 · D -72458 Albstadt Phone + 49 (0) 74 31/ 801- 0 · Fax 801-12 20 www.honeywell.com/security/de [email protected] 04. 2010 · Subject to change without notice. ©2010 Honeywell International Inc. Central control unit versions 026580 Basic ACS -8 system, 12 V DC approval Z 105009, class C 026585 Basic ACS -8 system, 230 V AC (includes 010690.02 power supply/charger unit) approval Z 105009, class C 026575 Basic ACS -8 system with freely-selectable power supply unit integration (power supply unit selection depends on the connected consumers, VdS only with power supply units approved by VdS) approval Z 105009, class C 026587 Communication module (required for controlling more than 2 doors) Item no. Description Item no. Description Order data Module bus users/ RS-485 modules 026590 Input module, RS-485 with potential separation 026591 Output module, RS-485 with potential separation 026592 Input/Output module, RS-485 with potential separation 026595 Potential seperation module, RS-485 026593 Door module, 12, V DC, RS-485 with potential separation 026594 Door module, 230 V AC, RS-485 with potential separation •4 digital inputs (e.g.: door strike push-button, monitoring contact, etc.) •8 differential detector groups (e.g.: magnetic contact, glass breakage sensor, etc.) •Integrated tamper contact •Optional host interfaces (RS-485, RS-232, 10/100 Mbit/s fast ethernet, Current Loop) •Variable door release, monitoring and alarm times •Automatic function control via time zones (e.g.: door release, etc.) Additional performance features •Special relay function for real-time release for rescue route integration •RS-485 module bus (optional) •Flexible power supply unit configuration, depending on power requirement •12 V DC emergency power supply, depending on power supply unit configuration and power requirement •VdS-approval Z 105009, class C •Support of analog modems and ISDN terminal adapters •Direct modem connection without additional card • RS-485 magnetic card reader • RS-485 Legic reader • RS-485 mifare reader • RS-485 Esser reader contactless • RS-485 keypad • RS-485 Fingerkey • RS-485 12 V version / 230 V version door module The following components can be connected to the communication module • RS-485 input module • RS-485 output module • RS-485 input/output module • Biometrics: Fingerkey and/or integration of bio- metrical systems via RS-485 module bus •Arming/disarming of an intrusion detection system via AC-readers to be realized using inputs/outputs and macro programming in IQ MultiAccess Accessories 026692 RS-485 interface (5-wire) without potential separation 026693 RS-485 interface (5-wire) with potential separation 026840.03 Asynchronous RS-232 host interface 026840.16 Current Loop interface 026840.29 10 /100 MBit/s ethernet host interface 018002.10 Rechargeable battery 12 V DC / 2.0 Ah 018003.10 Rechargeable battery 12 V DC / 3.5 Ah 012168 Power supply/charging unit 80 Ah/permanent current drain: 3,5 A 012170 Power supply/charging unit 130 Ah/permanent current drain: 5,0 A