11 68-0134T8624C,D
INSTALLATION • CHECKOUT
Fig. 11—Mounting thermostat on subbase.
M3764
PMRETURNMON
HEAT ONSYSTEM
A
U
T
O
PMR
E
TU
R
N M
O
N
H
E
A
T
 O
NSYSTEM
R
U
N
P
R
O
G
R
A
M
T
I
M
ET
E
M
P
E
R
A
T
U
R
E
P
R
E
S
E
N
T
S
E
T
T
IN
G
S
K
IP
N
E
X
T
P
E
R
IO
D
C
H
A
N
G
E
T
O
 
L
A
S
T
P
E
R
I
O
D S
E
T
P
R
E
S
E
N
T
D
A
Y
/T
IM
E
H
O
L
D
T
E
M
PA
H
E
A
DW
A
R
M
E
R
B
A
C
KC
O
O
L
E
R
A.
B.
C.
HEATAUTOCOOLOFFO
NA
U
T
OF
A
N
P
E
R
IO
DWAKE
SLEEP
RETURN LEAVEDAY
SET
HEAT/COOL
Checkout
HEATING
Move the...

Page 12

12
System PressLook For This ResponseSwitch
PositionThis
KeyKey
Down Key Released
OFF 06 Blank
02 Blank
05 Blank
04 Blank
01 Blank
00 Blank
(CHECK
EACH
POSITION)12 See note A
OFF 08 Blank
13 Microprocessor
mask no. and
revision no.
09 Blank
14 Blank
HEAT or
AUTO14 1st stage heating
and SYSTEM
LED on.
14 2nd stage heating
also on.
14 2nd stage heating
off.  
14 1st stage heating
and SYSTEM
LED off.
NOTE: If single-stage heating system, press key twice
instead of four times; once to turn on heating and...

Page 13

13 68-0134T8624C,D
CHECKOUT
Third
DigitManual or Auto
ChangeoverSystem Switch
Position
0 Manual HEAT or OFF
1 Auto HEAT or OFF
3 Auto AUTO
4 Manual COOL
5 Auto COOL
Fourth
Digit DegreesClock
(hrs)System Switch
Position
0 F 12 COOL, AUTO
or OFF
1 F 24 COOL, AUTO
or OFF
2 F 12 HEAT
3 F 24 HEAT
4 C 12 COOL, AUTO
or OFF
5 C 24 COOL, AUTO
or OFF
6 C 12 HEAT
7 C 24 HEAT
Second  Stages ofDigit
Heat Cool
021
122
211
312
402
510
620
First DigitCycle Rate Setting (cph at 50% on
time for stage 1 on 1-heat models,...

Page 14

14
Programming the Thermostat
IMPORTANT: With Adaptive Intelligent Recovery™,
program the times for when the homeowner wants
the home comfortable. The thermostat will decide
how early to begin the temperature changes.NOTE: Some models will show 32°F instead of the
current temperature, indicating the thermostat is op-
erating on backup batteries until the thermostat is
mounted on the wallplate and the system is powered.
STEP 1
SET THE CURRENT DAY AND
TIME
This thermostat can be programmed either
on the...

Page 15

15 68-0134temperature disappear from
the display.
Press and release. The display
shows LEAVE, but no time
or temperature.
Press and hold until the dis-
play shows the desired starting time. is 75° F, the maximum heating setting is
72° F.
Program the LEAVE time and tempera-
ture, if desired.
NOTE: The LEAVE, RETURN or SLEEP
program may be canceled by holding
down the period key until the time and
LEAVE
T8624C,D
PROGRAMMING THE THERMOSTAT
BACK
AHEAD
WARMER
COOLER
MON TUE WED THU FRI ON HEAT
LEAVESET
PT...

Page 16

16 T8624C,D
PROGRAMMING THE THERMOSTAT
SLEEP
WAKEPress and hold until SUN ap-
pears on the display.
Press WAKE, LEAVE, RE-
TURN or SLEEP to select
the time period.
Use the AHEAD/BACK keys
to set the time and theLEAVE
RETURN
BACK
AHEADWARMER
COOLER
WARMER/COOLER keys to set the temperature.
This completes setting the program schedule and heat-
ing temperatures. To set air conditioning, go to Step 3.
First program the WAKE tem-
perature for weekdays.
Press and release. The display shows WAKE and the
time...

Page 17

17 68-0134T8624C,D
PROGRAMMING THE THERMOSTAT
Program the RETURN tem-
perature, if
desired.
MON TUE WED THU FRI COOL
RETURNPMSET
PT
M5038
WARMER
COOLER
Press and release. The display shows RE-
TURN, the time programmed for heating,and
78° F.
Press and hold until the
display shows the desired tem-
perature.
Program the SLEEP tempera-MON TUE WED THU FRI COOL
SLEEPPMSET
PT
M5039
MON TUE WED THU FRI COOL
SLEEPPMSET
PT
M5040
WARMER
COOLER
ture, if desired.
Press and release.DAYPress and hold until the dis-...

Page 18

18 T8624C,D
PROGRAMMING THE THERMOSTAT • OPERATING THE THERMOSTAT
ON
AUTO ON
M3763AUTO
FAN
FANSET THE SYSTEM AND FAN
SWITCHES ON THE SUB-
BASE.
Depending on thermostat model,
some of the switch positions shown
may not be available on the ther-
mostat. Note the positions provided
on the subbase, then set the
switch(es) as desired.
First set the fan switch.
FAN ON: The fan runs continuously. Use for improved
air circulation during special occasions or for more effi-
cient electronic air
FAN AUTO: Normal...

Page 19

19 68-0134T8624C,D
OPERATING THE THERMOSTAT
WARMER
COOLER
To temporarily raise or lower the tempera-
ture for the current period only:
TEMPORARYM5046
ON HEATPress and hold until the de-
sired temperature is reached.
The display will flash TEM-
PORARY until the next pro-
grammed time period starts.
With the system switch at the
AUTO position, press and
hold down the key to alter-
nate between heating and cool-
ing temperature settings for
temporary override.
Press and release to cancel
any of the...

Page 20

20day and Sunday settings are
canceled separately.
Press and hold the desired pe-
riod key until the time and temperature clear from the
display (about three seconds).
Press and release to return to T8624C,D
OPERATING THE THERMOSTAT
SLEEPNOTE: Moving the system switch also can-
cels hold.
CANCELING THE PROGRAM
SETTINGS
The thermostat requires time and tempera-
ture settings in the WAKE period, but any of
the others can be canceled. Weekday, Satur-
LEAVE
RETURN
MON TUE WED THU FRI ON HEAT
LEAVE
M5052
RUN...