Page 241

Xenon/Granit User Guide 221
Codablock A

Codablock A On/Off
If you are reading Code 39 bar codes, Codablock A should remain disabled. If you 
are enabling Codablock A, you should disable Code 39 (see Code 39 on page 189).
Codablock A Message Length
Scan the bar codes below to change the message length. Refer to Message Length 
Description (page 186) for additional information. Minimum and Maximum 
lengths = 1-600. Minimum Default = 1, Maximum Default = 600.
On
* Off
Minimum Message Length
Maximum Message...

Page 242

222 Xenon/Granit User Guide
Codablock F

Codablock F On/Off
If you are reading Code 128 bar codes, Codablock F should remain disabled. If you 
are enabling Codablock F, you should disable Code 128 (see Code 128 on page 
201).
Codablock F Message Length
Scan the bar codes below to change the message length. Refer to Message Length 
Description (page 186) for additional information. Minimum and Maximum 
lengths = 1-2048. Minimum Default = 1, Maximum Default = 2048.
Label Code
The standard Label Code is...

Page 243

Xenon/Granit User Guide 223
PDF417
< Default All PDF417 Settings >
PDF417 On/Off
PDF417 Message Length
Scan the bar codes below to change the message length. Refer to Message Length 
Description (page 186) for additional information. Minimum and Maximum 
lengths = 1-2750. Minimum Default = 1, Maximum Default = 2750.
*Off
* On
Off
 Minimum Message Length
Maximum Message Length 

Page 244

224 Xenon/Granit User Guide
MacroPDF417
MacroPDF417 is an implementation of PDF417 capable of encoding very large 
amounts of data into multiple PDF417 bar codes. When this selection is enabled, 
these multiple bar codes are assembled into a single data string. Default=On. 
MicroPDF417
< Default All MicroPDF417 Settings >
MicroPDF417 On/Off
MicroPDF417 Message Length
Scan the bar codes below to change the message length. Refer to Message Length 
Description (page 186) for additional information. Minimum...

Page 245

Xenon/Granit User Guide 225
GS1 Composite Codes
Linear codes are combined with a unique 2D composite component to form a new 
class called GS1 Composite symbology. GS1 Composite symbologies allow for the 
co-existence of symbologies already in use. Default=Off.
UPC/EAN Version
Scan the UPC/EAN Version On bar code to decode GS1 Composite symbols that 
have a U.P.C. or an EAN linear component. (This does not affect GS1 Composite 
symbols with a GS1-128 or GS1 linear component.) Default=UPC/EAN Version...

Page 246

226 Xenon/Granit User Guide
GS1 Emulation
The scanner can automatically format the output from any GS1 data carrier to 
emulate what would be encoded in an equivalent GS1-128 or GS1 DataBar symbol. 
GS1 data carriers include UPC-A and UPC-E, EAN-13 and EAN-8, ITF-14, GS1-
128, and GS1-128 DataBar and GS1 Composites. (Any application that accepts 
GS1 data can be simplified since it only needs to recognize one data carrier type.)
If GS1-128 Emulation is scanned, all retail codes (U.P.C., UPC-E, EAN8,...

Page 247

Xenon/Granit User Guide 227
TCIF Linked Code 39 (TLC39)
This code is a composite code since it has a Code 39 linear component and a 
MicroPDF417 stacked code component. All bar code readers are capable of read-
ing the Code 39 linear component. The MicroPDF417 component can only be 
decoded if TLC39 On is selected. The linear component may be decoded as Code 
39 even if TLC39 is off. Default=Off. 
QR Code
< Default All QR Code Settings >
QR Code On/Off
This selection applies to both QR Code and Micro QR...

Page 248

228 Xenon/Granit User Guide
QR Code Append
This function allows the scanner to append the data from several QR Code bar 
codes together before transmitting them to the host computer. When the scanner 
encounters an QR Code bar code with the append trigger character(s), it buffers 
the number of QR Code bar codes determined by information encoded in those bar 
codes. Once the proper number of codes is reached, the data is output in the order 
specified in the bar codes. Default=On.
QR Code Page
QR Code...

Page 249

Xenon/Granit User Guide 229
Data Matrix
< Default All Data Matrix Settings >
Data Matrix On/Off
Data Matrix Message Length
Scan the bar codes below to change the message length. Refer to Message Length 
Description (page 186) for additional information. Minimum and Maximum 
lengths = 1-3116. Minimum Default = 1, Maximum Default = 3116.
Data Matrix Code Page
Data Matrix Code pages define the mapping of character codes to characters. If the 
data received does not display with the proper characters, it may...

Page 250

230 Xenon/Granit User Guide
MaxiCode
< Default All MaxiCode Settings >
MaxiCode On/Off
MaxiCode Message Length
Scan the bar codes below to change the message length. Refer to Message Length 
Description (page 186) for additional information. Minimum and Maximum 
lengths = 1-150. Minimum Default = 1, Maximum Default = 150.
On
* Off
Minimum Message Length
Maximum Message Length 