Page 241
Xenon/Granit User Guide 221 Codablock A Codablock A On/Off If you are reading Code 39 bar codes, Codablock A should remain disabled. If you are enabling Codablock A, you should disable Code 39 (see Code 39 on page 189). Codablock A Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 186) for additional information. Minimum and Maximum lengths = 1-600. Minimum Default = 1, Maximum Default = 600. On * Off Minimum Message Length Maximum Message...
Page 242
222 Xenon/Granit User Guide Codablock F Codablock F On/Off If you are reading Code 128 bar codes, Codablock F should remain disabled. If you are enabling Codablock F, you should disable Code 128 (see Code 128 on page 201). Codablock F Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 186) for additional information. Minimum and Maximum lengths = 1-2048. Minimum Default = 1, Maximum Default = 2048. Label Code The standard Label Code is...
Page 243
Xenon/Granit User Guide 223 PDF417 < Default All PDF417 Settings > PDF417 On/Off PDF417 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 186) for additional information. Minimum and Maximum lengths = 1-2750. Minimum Default = 1, Maximum Default = 2750. *Off * On Off Minimum Message Length Maximum Message Length
Page 244
224 Xenon/Granit User Guide MacroPDF417 MacroPDF417 is an implementation of PDF417 capable of encoding very large amounts of data into multiple PDF417 bar codes. When this selection is enabled, these multiple bar codes are assembled into a single data string. Default=On. MicroPDF417 < Default All MicroPDF417 Settings > MicroPDF417 On/Off MicroPDF417 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 186) for additional information. Minimum...
Page 245
Xenon/Granit User Guide 225 GS1 Composite Codes Linear codes are combined with a unique 2D composite component to form a new class called GS1 Composite symbology. GS1 Composite symbologies allow for the co-existence of symbologies already in use. Default=Off. UPC/EAN Version Scan the UPC/EAN Version On bar code to decode GS1 Composite symbols that have a U.P.C. or an EAN linear component. (This does not affect GS1 Composite symbols with a GS1-128 or GS1 linear component.) Default=UPC/EAN Version...
Page 246
226 Xenon/Granit User Guide GS1 Emulation The scanner can automatically format the output from any GS1 data carrier to emulate what would be encoded in an equivalent GS1-128 or GS1 DataBar symbol. GS1 data carriers include UPC-A and UPC-E, EAN-13 and EAN-8, ITF-14, GS1- 128, and GS1-128 DataBar and GS1 Composites. (Any application that accepts GS1 data can be simplified since it only needs to recognize one data carrier type.) If GS1-128 Emulation is scanned, all retail codes (U.P.C., UPC-E, EAN8,...
Page 247
Xenon/Granit User Guide 227 TCIF Linked Code 39 (TLC39) This code is a composite code since it has a Code 39 linear component and a MicroPDF417 stacked code component. All bar code readers are capable of read- ing the Code 39 linear component. The MicroPDF417 component can only be decoded if TLC39 On is selected. The linear component may be decoded as Code 39 even if TLC39 is off. Default=Off. QR Code < Default All QR Code Settings > QR Code On/Off This selection applies to both QR Code and Micro QR...
Page 248
228 Xenon/Granit User Guide QR Code Append This function allows the scanner to append the data from several QR Code bar codes together before transmitting them to the host computer. When the scanner encounters an QR Code bar code with the append trigger character(s), it buffers the number of QR Code bar codes determined by information encoded in those bar codes. Once the proper number of codes is reached, the data is output in the order specified in the bar codes. Default=On. QR Code Page QR Code...
Page 249
Xenon/Granit User Guide 229 Data Matrix < Default All Data Matrix Settings > Data Matrix On/Off Data Matrix Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 186) for additional information. Minimum and Maximum lengths = 1-3116. Minimum Default = 1, Maximum Default = 3116. Data Matrix Code Page Data Matrix Code pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may...
Page 250
230 Xenon/Granit User Guide MaxiCode < Default All MaxiCode Settings > MaxiCode On/Off MaxiCode Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 186) for additional information. Minimum and Maximum lengths = 1-150. Minimum Default = 1, Maximum Default = 150. On * Off Minimum Message Length Maximum Message Length