Page 11
11 Command Control via the Network When the projector connects network, the projector can be controlled with RS- 232C commands from the computer with web browser. For details of RS-232C commands, refer to RS-232C Communication / Network command table (&17). Connection 1. Turn off the projector and the computer. 2. Connect the projector's LAN port and the computer's LAN port with a LAN cable. Use the cable that fulfi lls the specifi cation shown in fi gure (Use CAT-5 or greater LAN Cable when...
Page 12
12 Communicaion Port The following two ports are assigned for the command control.TCP #23 TCP #9715 Configure the following items form a web browser when command control is used. Port Settings Network Control Port1 (Port: 23) Port open Click the [Enable] check box to open [Network Control Port1 (Port: 23)] to use TCP #23. Default setting is “Enable”. Authentication Click the [Enable] check box for the [Authentication] setting when authentication is required. Default setting is “Disable”. Network...
Page 13
13 Command Control via the Network (continued) Command control settings [TCP #23] 1. Command format Same as RS-232C communication, refer to RS-232C Communicaton command format. 2. Response code / Error code ("h" shows hexadecimal) Four of the response / error code used for TCP#23 are the same as RS-232C Communication (1)~(4). One authentication error reply (5) is added. (1) ACK reply : 06h Refer to RS-232C communication ( &10). (2) NAK reply : 15h Refer to RS-232C communication ( &10)....
Page 14
14 2. Response code / Error code ("h" shows hexadecimal) The connection ID is attached for the TCP#23's response / error codes are used. The connection ID is same as the sending command format. (1) ACK reply : 06h + ××h (××h : connection ID) (2) NAK reply : 15h + ××h (3) Error reply : 1Ch + 0000h + ××h (4) Data reply : 1Dh + xxxxh + ××h (5) Authentication error reply : 1Fh + 0400h + ××h (6) Projector busy reply: 1Fh + ××××h + ××h When the projector is too...
Page 15
15 This projector is equipped with NETWORK BRIDGE function. When the projector connects to the computer by LAN communicaton, an external device that is connected with this projector by RS-232C communication can be controlled from the computer as a network terminal. For details, see the 6. Network Bridge Function - Network Guide. Connection 1. Connect the computer's LAN port and the projector's LAN port with a LAN cable. 2. Connect the projector's CONTROL port and the RS-232C...
Page 16
16 Communication settings For communication setting, use the OPTION - SERVICE - COMMUNICATION menu. ( &OPTION menu - SERVICE - COMMUNICATION in the User's Manual - Operating Guide ) Item Condition BAUD RATE 4800bps / 9600bps / 19200bps / 38400bps Data length 8 bit (fixed) PARITY NONE/ODD/EVEN Start bit 1 bit (fixed) Stop bit 1 bit (fixed) Transmission method HALF-DUPLEX/FULL-DUPLEX NOTE • For connecting the projector to your devices, please read the manual for each devices, and connect...
Page 17
17 RS-232C Communication / Network command table NamesOperation Type Header Command DataCRC Action TypeSetting code Power Set Turn off BE EF0306 00 2A D3 01 0000 60 00 00 Turn on BE EF0306 00 BA D2 01 0000 60 01 00 Get BE EF 0306 00 19 D3 02 0000 60 00 00 [Example return] 00 00 01 00 02 00 [Off] [On] [Cool down] Input SourceSetCOMPUTER IN1 BE EF0306 00 FE D2 01 0000 20 00 00 COMPUTER IN2 BE EF0306 00 3E D0 01 0000 20 04 00 HDMI BE EF0306 00 0E D2 01 0000 20 03 00...
Page 18
RS-232C Communication / Network command table (continued) 18(continued on next page) NamesOperation Type Header Command DataCRC Action TypeSetting code CONTRAST ResetExecute BE EF0306 00 A4 D2 06 0001 70 00 00 GAMMASet1 DEFAULT BE EF0306 00 07 E9 01 00A1 30 20 00 1 CUSTOM BE EF0306 00 07 FD 01 00A1 30 10 00 2 DEFAULT BE EF0306 00 97 E8 01 00A1 30 21 00 2 CUSTOM BE EF0306 00 97 FC 01 00A1 30 11 00 3 DEFAULT BE EF0306 00 67 E8 01 00A1 30 22 00 3 CUSTOM BE EF0306 00 67...
Page 19
RS-232C Communication / Network command table (continued) 19(continued on next page) NamesOperation Type Header Command DataCRC Action TypeSetting code User Gamma Point 7Get BE EF0306 00 80 FE 02 0096 30 00 00 Increment BE EF0306 00 E6 FE 04 0096 30 00 00 Decrement BE EF0306 00 37 FF 05 0096 30 00 00 User Gamma Point 7 ResetExecute BE EF0306 00 D0 C2 06 0056 70 00 00 User Gamma Point 8Get BE EF0306 00 7C FF 02 0097 30 00 00 Increment BE EF0306 00 1A FF 04 0097 30 00...
Page 20
RS-232C Communication / Network command table (continued) 20(continued on next page) NamesOperation Type Header Command DataCRC Action TypeSetting code COLOR TEMP OFFSET BGet BE EF0306 00 BC F4 02 00B7 30 00 00 Increment BE EF0306 00 DA F4 04 00B7 30 00 00 Decrement BE EF0306 00 0B F5 05 00B7 30 00 00 COLOR TEMP OFFSET B ResetExecute BE EF0306 00 C8 C5 06 004C 70 00 00 COLOR Get BE EF0306 00 B5 72 02 0002 22 00 00 Increment BE EF0306 00 D3 72 04 0002 22 00 00...