Home > Hitachi > Projector > Hitachi Ed-X22 Projector Users Manual

Hitachi Ed-X22 Projector Users Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Hitachi Ed-X22 Projector Users Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 913 Hitachi manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							4
    K
    COMPUTER IN1COMPUTER IN2USBAUDIO IN1
    AUDIO IN2
    S-VIDEO
    VIDEO
    MONITOR OUT CONTROLAUDIO OUT
    Connection to the ports (continued)
    4 321
    EVIDEO
    RCA jack
    • System: NTSC, PAL, SECAM, PAL-M, PAL-N, NTSC4.43
    ‡“9SS
    WHUPLQDWRU
    FAUDIO IN1, GAUDIO IN2, 
    Ø3.5 stereo mini jack
    ‡P9UPVNŸWHUPLQDWRU
    HAUDIO OUT
    Ø3.5 stereo mini jack
    ‡P9UPVNŸRXWSXWLPSHGDQFH
    DS-VIDEO
    Mini DIN 4pin jack
    Pin Signal
    1
    &RORUVLJQDO9SS3$/6(&$0EXUVW
    WHUPLQDWRU
    2%ULJKWQHVVVLJQDO9SS
    WHUPLQDWRU
    3Ground
    4Ground
    E
    DF
    HG 
    						
    							5
    Connection to the ports (continued)
    K
    COMPUTER IN1COMPUTER IN2USBAUDIO IN1
    AUDIO IN2
    S-VIDEO
    VIDEO
    MONITOR OUT CONTROLAUDIO OUT
    IUSB
    USB B type jack
    Pin Signal
    1 +5V
    2 - Data
    3 + Data
    4 Ground21
    34
    I
    J
    JCONTROL
    D-sub 9pin plug
    Pin Signal Pin Signal Pin Signal
    1 (No connection) 4 (No connection) 7 RTS
    2 RD 5 Ground 8 CTS
    3 TD 6 (No connection) 9 (No connection)
    9876
    54321 
    						
    							6
    RS-232C Communication
    RS-232C Communication
    6
    78
    9 123456
    78
    9 12345
    CONTROL port RS-232C cable (Cross) RS-232C port
    of the projector of the PC
    - (1) (1) CD
    RD (2) (2) RD
    TD (3) (3) TD
    - (4) (4) DTR
    GND (5) (5) GND
    - (6) (6) DSR
    RTS (7) (7) RTS
    CTS (8) (8) DTS
    - (9) (9) RI
    Connecting the cable
    1.Turn off the projector and the PC.
    2.Connect the CONTROL port of the projector with a RS-232C port of the PC 
    L¿FDWLRQVKRZQ
    in the previous page.
    3.Turn the PC on, and after the PC has started up turn the projector on.
    Communications setting
    19200bps, 8N1
    1. Protocol
    Consist of header (7 bytes) + command data (6 bytes).
    2. Header
    BE + EF + 03 + 06 + 00 + CRC_low + CRC_high
    &5&BORZ/RZHUE\WHRI&5&ÀDJIRUFRPPDQGGDWD
    &5&BKLJK8SSHUE\WHRI&5&ÀDJIRUFRPPDQGGDWD
    3. Command data
    Command data chart
    byte_0 byte_1 byte_2 byte_3 byte_4 byte_5
    Action Type Setting code
    low high low high low high
    Action (byte_0 - 1)
    Action&ODVVL¿FDWLRQContent
    1 SET Change setting to desired value.
    2 GET Read projector internal setup value.
    4 INCREMENT Increment setup value by 1.
    5 DECREMENT Decrement setup value by 1.
    6 EXECUTE Run a command. 
    						
    							7
    RS-232C Communication (continued)
    Requesting projector status (Get command)
    (1) Send the following request code from the PC to the projector.
    Header + Command data (‘02H’ + ‘00H’ + type (2 bytes) + ‘00H’ + ‘00H’)
    (2) The projector returns the response code ‘1DH’ + data (2 bytes) to the PC.
    Changing the projector settings (Set command)
    (1) Send the following setting code from the PC to the projector.
      Header + Command data (‘01H’ + ‘00H’ + type (2 bytes) + setting code (2 
    bytes))
    (2) The projector changes the setting based on the above setting code.
    (3) The projector returns the response code ‘06H’ to the PC.
    Using the projector default settings (Reset Command)
    (1) The PC sends the following default setting code to the projector.
    Header + Command data (‘06H’ + ‘00H’ + type (2 bytes) + ‘00H’ + ‘00H’)
    DOXH
    (3) The projector returns the response code ‘06H’ to the PC.
    Increasing the projector setting value (Increment command)
    (1) The PC sends the following increment code to the projector.
    Header + Command data (‘04H’ + ‘00H’ + type (2 bytes) + ‘00H’ + ‘00H’)
    (2) The projector increases the setting value on the above setting code.
    (3) The projector returns the response code ‘06H’ to the PC.
    Decreasing the projector setting value (Decrement command)
    (1) The PC sends the following decrement code to the projector.
    Header + Command data (‘05H’ + ‘00H’ + type (2 bytes) + ‘00H’ + ‘00H’)
    (2) The projector decreases the setting value on the above setting code.
    (3) The projector returns the response code ‘06H’ to the PC.
    When the projector cannot understand the received command
    When the projector cannot understand the received command, the error code ‘15H’ 
    is sent back to the PC.
    Sometimes the projector cannot properly receive the command. In such a case, 
    the command is not executed and the error code ‘15H’ is sent back to the PC. If 
    this error code is returned, send the same command again.
    When the projector cannot execute the received command
    When the projector cannot execute the received command, the error code ‘1CH’ + 
    ‘xxxxH’ is sent back to the PC. 
    When the data length is greater than indicated by the data length code, the 
    projector ignore the excess data code. Conversely when the data length is shorter 
    than indicated by the data length code, an error code will be returned to the PC.
    NOTEQXQGH¿QHG
    command or data.
    • Provide an interval of at least 40ms between the response code and any other code.
    • The projector outputs test data when the power supply is switched ON, and when the 
    lamp is lit. Ignore this data.
    • Commands are not accepted during warm-up. 
    						
    							8
    Names Operation Type HeaderCommand Data
    CRC Action Type Setting Code
    Power Set Turn off BE EF 03 06 00 2A D3 01 00 00 60 00 00
    Turn on BE EF
    03 06 00 BA D2 01 00 00 60 01 00
    Get BE EF 03 06 00 19 D3 02 00 00 60 00 00
    [Example return]
    00 00 01 00 02 00
    [Off] [On] [Cool down]
    Input SourceSet COMPUTER 1 BE EF 03 06 00 FE D2 01 00 00 20 00 00
    COMPUTER 2 BE EF
    03 06 00 3E D0 01 00 00 20 04 00
    VIDEO BE EF 03 06 00 6E D3 01 00 00 20 01 00
    S-VIDEO BE EF 03 06 00 9E D3 01 00 00 20 02 00
    Get BE EF 03 06 00 CD D2 02 00 00 20 00 00
    Error Status
    Get BE EF 03 06 00 D9 D8 02 00 20 60 00 00
    [Example return]
    00 00 01 00 02 00 03 00
    [Normal] [Cover error] [Fan error] [Lamp error]
    04 00 05 00 06 00 07 00
     >7HPSHUURU@ >$LU
    						
    							9
    Names Operation Type HeaderCommand Data
    CRC Action Type Setting Code
    User Gamma Pattern Set Off BE EF 03 06 00 FB FA 01 00 80 30 00 00
    9 step gray scale BE EF03 06 00 6B FB 01 00 80 30 01 00
    15 steps gray scale BE EF03 06 00 9B FB 01 00 80 30 02 00
    Ramp BE EF 03 06 00 0B FA 01 00 80 30 03 00
    Get BE EF 03 06 00 C8 FA 02 00 80 30 00 00
    User Gamma Point 1Get BE EF 03 06 00 08 FE 02 00 90 30 00 00
    Increment BE EF03 06 00 6E FE 04 00 90 30 00 00
    Decrement BE EF 03 06 00 BF FF 05 00 90 30 00 00
    User Gamma Point 2Get BE EF 03 06 00 F4 FF 02 00 91 30 00 00
    Increment BE EF 03 06 00 92 FF 04 00 91 30 00 00
    Decrement BE EF 03 06 00 43 FE 05 00 91 30 00 00
    User Gamma Point 3Get BE EF 03 06 00 B0 FF 02 00 92 30 00 00
    Increment BE EF 03 06 00 D6 FF 04 00 92 30 00 00
    Decrement BE EF 03 06 00 07 FE 05 00 92 30 00 00
    User Gamma Point 4Get BE EF 03 06 00 4C FE 02 00 93 30 00 00
    Increment BE EF 03 06 00 2A FE 04 00 93 30 00 00
    Decrement BE EF 03 06 00 FB FF 05 00 93 30 00 00
    User Gamma Point 5Get BE EF 03 06 00 38 FF 02 00 94 30 00 00
    Increment BE EF 03 06 00 5E FF 04 00 94 30 00 00
    Decrement BE EF 03 06 00 8F FE 05 00 94 30 00 00
    User Gamma Point 6Get BE EF 03 06 00 C4 FE 02 00 95 30 00 00
    Increment BE EF 03 06 00 A2 FE 04 00 95 30 00 00
    Decrement BE EF 03 06 00 73 FF 05 00 95 30 00 00
    User Gamma Point 7Get BE EF 03 06 00 80 FE 02 00 96 30 00 00
    Increment BE EF 03 06 00 E6 FE 04 00 96 30 00 00
    Decrement BE EF 03 06 00 37 FF 05 00 96 30 00 00
    User Gamma Point 8Get BE EF 03 06 00 7C FF 02 00 97 30 00 00
    Increment BE EF 03 06 00 1A FF 04 00 97 30 00 00
    Decrement BE EF 03 06 00 CB FE 05 00 97 30 00 00
    COLOR TEMP Set HIGH BE EF 03 06 00 0B F5 01 00 B0 30 03 00
    MID BE EF 03 06 00 9B F4 01 00 B0 30 02 00
    LOW BE EF 03 06 00 6B F4 01 00 B0 30 01 00
    Hi-BRIGHT-1 BE EF 03 06 00 3B F2 01 00 B0 30 08 00
    Hi-BRIGHT-2 BE EF 03 06 00 AB F3 01 00 B0 30 09 00
    CUSTOM-1 BE EF 03 06 00 CB F8 01 00 B0 30 13 00
    CUSTOM-2 BE EF 03 06 00 5B F9 01 00 B0 30 12 00
    CUSTOM-3 BE EF 03 06 00 AB F9 01 00 B0 30 11 00
    CUSTOM-4 BE EF 03 06 00 FB FF 01 00 B0 30 18 00
    CUSTOM-5 BE EF 03 06 00 6B FE 01 00 B0 30 19 00
    Get BE EF 03 06 00 C8 F5 02 00 B0 30 00 00
    COLOR TEMP GAIN RGet BE EF 03 06 00 34 F4 02 00 B1 30 00 00
    Increment BE EF 03 06 00 52 F4 04 00 B1 30 00 00
    Decrement BE EF 03 06 00 83 F5 05 00 B1 30 00 00
    COLOR TEMP GAIN GGet BE EF 03 06 00 70 F4 02 00 B2 30 00 00
    Increment BE EF 03 06 00 16 F4 04 00 B2 30 00 00
    Decrement BE EF 03 06 00 C7 F5 05 00 B2 30 00 00
    RS-232C Communication (continued) 
    						
    							10
    Names Operation Type HeaderCommand Data
    CRC Action Type Setting Code
    COLOR TEMP GAIN B Get BE EF 03 06 00 8C F5 02 00 B3 30 00 00
    Increment BE EF 03 06 00 EA F5 04 00 B3 30 00 00
    Decrement BE EF 03 06 00 3B F4 05 00 B3 30 00 00
    COLOR TEMP
    OFFSET RGet BE EF 03 06 00 04 F5 02 00 B5 30 00 00
    Increment BE EF 03 06 00 62 F5 04 00 B5 30 00 00
    Decrement BE EF 03 06 00 B3 F4 05 00 B5 30 00 00
    COLOR TEMP
    OFFSET GGet BE EF 03 06 00 40 F5 02 00 B6 30 00 00
    Increment BE EF 03 06 00 26 F5 04 00 B6 30 00 00
    Decrement BE EF 03 06 00 F7 F4 05 00 B6 30 00 00
    COLOR TEMP
    OFFSET BGet BE EF 03 06 00 BC F4 02 00 B7 30 00 00
    Increment BE EF 03 06 00 DA F4 04 00 B7 30 00 00
    Decrement BE EF 03 06 00 0B F5 05 00 B7 30 00 00
    COLOR Get BE EF 03 06 00 B5 72 02 00 02 22 00 00
    Increment BE EF 03 06 00 D3 72 04 00 02 22 00 00
    Decrement BE EF 03 06 00 02 73 05 00 02 22 00 00
    COLOR ResetExecute BE EF 03 06 00 80 D0 06 00 0A 70 00 00
    TINT Get BE EF 03 06 00 49 73 02 00 03 22 00 00
    Increment BE EF 03 06 00 2F 73 04 00 03 22 00 00
    Decrement BE EF 03 06 00 FE 72 05 00 03 22 00 00
    TINT ResetExecute BE EF 03 06 00 7C D1 06 00 0B 70 00 00
    SHARPNESS Get BE EF 03 06 00 F1 72 02 00 01 22 00 00
    Increment BE EF 03 06 00 97 72 04 00 01 22 00 00
    Decrement BE EF 03 06 00 46 73 05 00 01 22 00 00
    SHARPNESS ResetExecute BE EF 03 06 00 C4 D0 06 00 09 70 00 00
    MY MEMORY LoadSet 1 BEEF 03 0600 0ED7 0100 1420 0000
    2 BEEF 03 0600 9ED6 0100 1420 0100
    3 BEEF 03 0600 6ED6 0100 1420 0200
    4 BEEF 03 0600 FED7 0100 1420 0300
    MY MEMORY SaveSet 1 BEEF 03 0600 F2D6 0100 1520 0000
    2 BEEF 03 0600 62D7 0100 1520 0100
    3 BEEF 03 0600 92D7 0100 1520 0200
    4 BEEF 03 0600 02D6 0100 1520 0300
    PROGRESSIVE Set TURN OFF BE EF 03 06 00 4A 72 01 00 07 22 00 00
    TV BE EF 03 06 00 DA 73 01 00 07 22 01 00
    FILM BE EF 03 06 00 2A 73 01 00 07 22 02 00
    Get BE EF 03 06 00 79 72 02 00 07 22 00 00
    VIDEO NRSet LOW BE EF 03 06 00 26 72 01 00 06 22 01 00
    MID BE EF 03 06 00 D6 72 01 00 06 22 02 00
    HIGH BE EF 03 06 00 46 73 01 00 06 22 03 00
    Get BE EF 03 06 00 85 73 02 00 06 22 00 00
    RS-232C Communication (continued) 
    						
    							11
    Names Operation Type HeaderCommand Data
    CRC Action Type Setting Code
    ASPECTSet 4:3 BE EF 03 06 00 9E D0 01 00 08 20 00 00
    16:9 BE EF 03 06 00 0E D1 01 00 08 20 01 00
    14:9 BE EF 03 06 00 CE D6 01 00 08 20 09 00
    SMALL BE EF 03 06 00 FE D1 01 00 08 20 02 00
    NORMAL BE EF 03 06 00 5E DD 01 00 08 20 10 00
    Get BE EF 03 06 00 AD D0 02 00 08 20 00 00
    OVER SCANGet BE EF 03 06 00 91 70 02 00 09 22 00 00
    Increment BE EF 03 06 00 F7 70 04 00 09 22 00 00
    Decrement BE EF 03 06 00 26 71 05 00 09 22 00 00
    OVER SCAN ResetExecute BE EF 03 06 00 EC D9 06 00 27 70 00 00
    V POSITIONGet BE EF 03 06 00 0D 83 02 00 00 21 00 00
    Increment BE EF 03 06 00 6B 83 04 00 00 21 00 00
    Decrement BE EF 03 06 00 BA 82 05 00 00 21 00 00
    V POSITION ResetExecute BE EF 03 06 00 E0 D2 06 00 02 70 00 00
    H POSITIONGet BE EF 03 06 00 F1 82 02 00 01 21 00 00
    Increment BE EF 03 06 00 97 82 04 00 01 21 00 00
    Decrement BE EF 03 06 00 46 83 05 00 01 21 00 00
    H POSITION ResetExecute BE EF 03 06 00 1C D3 06 00 03 70 00 00
    H PHASEGet BE EF 03 06 00 49 83 02 00 03 21 00 00
    Increment BE EF 03 06 00 2F 83 04 00 03 21 00 00
    Decrement BE EF 03 06 00 FE 82 05 00 03 21 00 00
    H SIZEGet BE EF 03 06 00 B5 82 02 00 02 21 00 00
    Increment BE EF 03 06 00 D3 82 04 00 02 21 00 00
    Decrement BE EF 03 06 00 02 83 05 00 02 21 00 00
    H SIZE ResetExecute BE EF 03 06 00 68 D2 06 00 04 70 00 00
    AUTO ADJUSTExecute BE EF 03 06 00 91 D0 06 00 0A 20 00 00
    COLOR SPACESet AUTO BE EF 03 06 00 0E 72 01 00 04 22 00 00
    RGB BE EF 03 06 00 9E 73 01 00 04 22 01 00
    SMPTE240 BE EF 03 06 00 6E 73 01 00 04 22 02 00
    REC709 BE EF 03 06 00 FE 72 01 00 04 22 03 00
    REC601 BE EF 03 06 00 CE 70 01 00 04 22 04 00
    Get BE EF 03 06 00 3D 72 02 00 04 22 00 00
    C-VIDEO FORMATSet AUTO BE EF 03 06 00 A2 70 01 00 11 22 0A 00
    NTSC BE EF 03 06 00 C2 74 01 00 11 22 04 00
    PAL BEEF 03 0600 5275 0100 1122 0500
    SECAM BE EF 03 06 00 52 70 01 00 11 22 09 00
    NTSC4.43 BE EF 03 06 00 62 77 01 00 11 22 02 00
    M-PAL BE EF 03 06 00 C2 71 01 00 11 22 08 00
    N-PAL BE EF 03 06 00 32 74 01 00 11 22 07 00
    Get BE EF 03 06 00 31 76 02 00 11 22 00 00
    S-VIDEO FORMATSet AUTO BE EF 03 06 00 E6 70 01 00 12 22 0A 00
    NTSC BE EF 03 06 00 86 74 01 00 12 22 04 00
    PAL BEEF 03 0600 1675 0100 1222 0500
    SECAM BE EF 03 06 00 16 70 01 00 12 22 09 00
    NTSC4.43 BE EF 03 06 00 26 77 01 00 12 22 02 00
    M-PAL BE EF 03 06 00 86 71 01 00 12 22 08 00
    N-PAL BE EF 03 06 00 76 74 01 00 12 22 07 00
    Get BE EF 03 06 00 75 76 02 00 12 22 00 00
    RS-232C Communication (continued) 
    						
    							12
    Names Operation Type HeaderCommand Data
    CRC Action Type Setting Code
    COMPUTER 1 Set SYNC ON G OFF BE EF 03 06 00 5E D7 01 00 10 20 02 00
    AUTO BE EF 03 06 00 CED6 0100 1020 0300
    Get BE EF 03 06 00 0D D6 02 00 10 20 00 00
    COMPUTER 2 Set SYNC ON G OFF BE EF 03 06 00 A2 D6 01 00 11 20 02 00
    AUTO BE EF 03 06 00 32D7 0100 1120 0300
    Get BE EF 03 06 00 F1 D7 02 00 11 20 00 00
    FRAME LOCKSet TURN OFF BE EF 03 06 00 CB D6 01 00 14 30 00 00
    TURN ON BE EF 03 06 00 5B D7 01 00 14 30 01 00
    Get BE EF 03 06 00 F8 D6 02 00 14 30 00 00
    KEYSTONE V Get BE EF 03 06 00 B9 D3 02 00 07 20 00 00
    Increment BE EF 03 06 00 DF D3 04 00 07 20 00 00
    Decrement BE EF 03 06 00 0E D2 05 00 07 20 00 00
    KEYSTONE V ResetExecute BE EF 03 06 00 08 D0 06 00 0C 70 00 00
    WHISPER Set BRIGHT BE EF 03 06 00 3B 23 01 00 00 33 00 00
    NORMAL BE EF 03 06 00 AB 22 01 00 00 33 01 00
    Get BE EF 03 06 00 08 23 02 00 00 33 00 00
    MIRROR Set NORMAL BE EF 03 06 00 C7 D2 01 00 01 30 00 00
    H:INVERT BE EF 03 06 00 57 D3 01 00 01 30 01 00
    V:INVERT BE EF 03 06 00 A7 D3 01 00 01 30 02 00
    H&V:INVERT BE EF 03 06 00 37 D2 01 00 01 30 03 00
    Get BE EF 03 06 00 F4 D2 02 00 01 30 00 00
    VOLUME-
    COMPUTER1Get BE EF 03 06 00 CD CC 02 00 60 20 00 00
    Increment BE EF 03 06 00 AB CC 04 00 60 20 00 00
    Decrement BE EF 03 06 00 7A CD 05 00 60 20 00 00
    VOLUME-
    COMPUTER2Get BE EF 03 06 00 FD CD 02 00 64 20 00 00
    Increment BE EF 03 06 00 9B CD 04 00 64 20 00 00
    Decrement BE EF 03 06 00 4A CC 05 00 64 20 00 00
    VOLUME-Video Get BE EF 03 06 00 31 CD 02 00 61 20 00 00
    Increment BE EF 03 06 00 57 CD 04 00 61 20 00 00
    Decrement BE EF 03 06 00 86 CC 05 00 61 20 00 00
    VOLUME-S-Video Get BE EF 03 06 00 75 CD 02 00 62 20 00 00
    Increment BE EF 03 06 00 13 CD 04 00 62 20 00 00
    Decrement BE EF 03 06 00 C2 CC 05 00 62 20 00 00
    RS-232C Communication (continued) 
    						
    							13
    RS-232C Communication (continued)
    Names Operation Type HeaderCommand Data
    CRC Action Type Setting Code
    MUTE Set TURN OFF BE EF 03 06 00 46 D3 01 00 02 20 00 00
    TURN ON BE EF03 06 00 D6 D2 01 00 02 20 01 00
    Get BE EF 03 06 00 75 D3 02 00 02 20 00 00
    AUDIO - COMPUTER1 Set TURN OFF BE EF 03 06 00 FE DD 01 00 30 20 00 00
    Audio1 BE EF 03 06 00 6E DC 01 00 30 20 01 00
    Audio2 BE EF 03 06 00 9E DC 01 00 30 20 02 00
    Get BE EF 03 06 00 CD DD 02 00 30 20 00 00
    AUDIO - COMPUTER2 Set TURN OFF BE EF 03 06 00 CE DC 01 00 34 20 00 00
    Audio1 BE EF 03 06 00 5E DD 01 00 34 20 01 00
    Audio2 BE EF 03 06 00 AE DD 01 00 34 20 02 00
    Get BE EF 03 06 00 FD DC 02 00 34 20 00 00
    AUDIO - Video Set TURN OFF BE EF 03 06 00 02 DC 01 00 31 20 00 00
    Audio1 BE EF 03 06 00 92 DD 01 00 31 20 01 00
    Audio2 BE EF 03 06 00 62 DD 01 00 31 20 02 00
    Get BE EF 03 06 00 31 DC 02 00 31 20 00 00
    AUDIO - S-Video Set TURN OFF BE EF 03 06 00 46 DC 01 00 32 20 00 00
    Audio1 BE EF 03 06 00 D6 DD 01 00 32 20 01 00
    Audio2 BE EF 03 06 00 26 DD 01 00 32 20 02 00
    Get BE EF 03 06 00 75 DC 02 00 32 20 00 00
    IR REMOTE FREQ.
    NORMALSet Off BE EF 03 06 00 FF3D 0100 3026 0000
    On BE EF 03 06 00 6F 3C 01 00 30 26 01 00
    Get BE EF 03 06 00 CC 3D 02 00 30 26 00 00
    IR REMOTE FREQ.
    HIGHSet Off BE EF 03 06 00 03 3C 01 00 31 26 00 00
    On BE EF 03 06 00 93 3D 01 00 31 26 01 00
    Get BE EF 03 06 00 30 3C 02 00 31 26 00 00
    LANGUAGE Set ENGLISH BE EF 03 06 00 F7 D3 01 00 05 30 00 00
    FRANÇAIS BE EF 03 06 00 67 D2 01 00 05 30 01 00
    DEUTSCH BE EF 03 06 00 97 D2 01 00 05 30 02 00
    ESPAÑOL BE EF 03 06 00 07 D3 01 00 05 30 03 00
    ITALIANO BE EF 03 06 00 37 D1 01 00 05 30 04 00
    NORSK BE EF 03 06 00 A7 D0 01 00 05 30 05 00
    NEDERLANDS BE EF 03 06 00 57 D0 01 00 05 30 06 00
    PORTUGUÊS BE EF 03 06 00 C7 D1 01 00 05 30 07 00
    BE EF 03 06 00 37 D4 01 00 05 30 08 00
    BE EF 03 06 00 A7 D5 01 00 05 30 09 00
    BE EF 03 06 00 37 DE 01 00 05 30 10 00
    BE EF 03 06 00 57 D5 01 00 05 30 0A 00
    SVENSKA BE EF 03 06 00 C7 D4 01 00 05 30 0B 00
    3M&&.BCBE EF 03 06 00 F7 D6 01 00 05 30 0C 00
    SUOMI BE EF 03 06 00 67 D7 01 00 05 30 0D 00
    POLSKI BE EF 03 06 00 97 D7 01 00 05 30 0E 00
    TÜRKÇE BE EF 03 06 00 07 D6 01 00 05 30 0F 00
    Get BE EF 03 06 00 C4 D3 02 00 05 30 00 00
    MENU POSITION HGet BE EF 03 06 00 04 D7 02 00 15 30 00 00
    Increment BE EF 03 06 00 62 D7 04 00 15 30 00 00
    Decrement BE EF 03 06 00 B3 D6 05 00 15 30 00 00
    MENU POSITION H ResetExecute BE EF 03 06 00 DC C6 06 00 43 70 00 00 
    						
    All Hitachi manuals Comments (0)