Home > Hitachi > Projector > Hitachi Cp D31n Technical Manual

Hitachi Cp D31n Technical Manual

Here you can view all the pages of manual Hitachi Cp D31n Technical Manual. The Hitachi manuals for Projector are available online for free. You can easily download all the documents as PDF.

Page 11

11
RS-232C Communication (continued)
Communicaion settings
1. Protocol
19200bps,8N1
2. Command format  ("h" shows hexadecimal)
Byte Number01 2 3456789101112
Command
ActionHeader Data
Header
code
Packet
Data
sizeCRC 
flagAction TypeSetting 
code
LH LHLHLHLHLH
Change setting to 
desired value [(cL)(cH)].
BEh EFh 03h 06h 00h(aL) (aH) 01h 00h (bL) (bH) (cL) (cH)
Read projector 
internal setup value [(bL)
(bH)].(aL) (aH) 02h 00h (bL) (bH) 00h 00h
 
Increment setup value 
[(bL)(bH)] by 1.(aL) (aH) 04h...

Page 12

12
RS-232C Communication (continued)
NOTE • Operation cannot be guaranteed when the projector receives an 
undefined command or data.
• Provide an interval of at least 40ms between the response code and any 
other code.
• The projector outputs test data when the power supply is switched ON, and 
when the lamp is lit. Ignore this data.
• Commands are not accepted during warm-up.
3. Response code / Error code ("h" shows hexadecimal)
(1)  ACK reply : 06h 
When the projector receives the Set,...

Page 13

13
Command Control via the Network
When the projector connects network, the projector can be controlled with RS-
232C commands from the computer with web browser. 
For details of RS-232C commands, refer to RS-232C Communication / Network 
command table 
(19).
Connection
1. Turn off the projector and the computer.
2. Connect the projector's LAN port and the computer's LAN port with a LAN 
cable. Use the cable that fulfi lls the specifi cation shown in fi gure (Use CAT-5 
or greater LAN Cable when...

Page 14

14
Communicaion Port
The following two ports are assigned for the command control.
TCP #23
TCP #9715
Configure the following items form a web browser when command control is used.
Port Settings
Network Control 
Port1 (Port: 23)Port openClick the [Enable] check box to open [Network 
Control Port1 (Port: 23)] to use TCP #23.
Default setting is “Enable”.
AuthenticationClick the [Enable] check box for the 
[Authentication] setting when authentication 
is required.
Default setting is “Disable”.
Network Control...

Page 15

15
Command Control via the Network (continued)
Command control settings
[TCP #23]
1. Command format
Same as RS-232C communication, refer to RS-232C Communicaton command format.
2. Response code / Error code ("h" shows hexadecimal)
Four of the response / error code used for TCP#23 are the same as RS-232C 
Communication (1)~(4). One authentication error reply (5) is added.
(1)  ACK reply : 06h 
Refer to RS-232C communication
 (12).
(2)  NAK reoly : 15h 
Refer to RS-232C communication
 (12).
(3)...

Page 16

16
2. Response code / Error code ("h" shows hexadecimal)
The connection ID is attached for the TCP#23's response / error codes are 
used. The connection ID is same as the sending command format.
(1) ACK reply : 06h + ××h                   (××h : connection ID)
(2) NAK reoly : 15h + ××h
(3) Error reply : 1Ch + 0000h + ××h
(4) Data reply : 1Dh + xxxxh + ××h
(5) Authentication error reply : 1Fh + 0400h + ××h
(6)  Projector busy reply: 1Fh + ××××h + ××h 
When the projector is too busy to receives...

Page 17

17
This projector is equipped with NETWORK BRIDGE function.
When the projector connects to the computer by LAN communicaton, an external 
device that is connected with this projector by RS-232C communication can be 
controlled from the computer as a network terminal.
For details, see the 3.7 Controlling the external device via the projector(using 
the NETWORK BRIDGE function) - Network Guide.
Connection
1. Connect the computer's LAN port and the projector's LAN port with a LAN 
cable.
2.
Connect...

Page 18

18
Communication settings 
For communication setting, use the OPTION - SERVICE - COMMUNICATION 
menu. (
OPTION menu - SERVICE - COMMUNICATION in the User's Manual 
- Operating Guide
)
Item Condition
BAUD RATE 4800bps / 9600bps / 19200bps / 38400bps
Data length 8 bit (fixed)
PARITY NONE/ODD/EVEN
Start bit 1 bit (fixed)
Stop bit 1 bit (fixed)
Transmission method HALF-DUPLEX/FULL-DUPLEX
NOTE • For connecting the projector to your devices, please read the 
manual for each devices, and connect them...

Page 19

19
Names Operation Type HeaderCommand Data
CRC Action Type Setting Code
Power Set OFF BE EF 03 06 00 2A D3 01 00 00 60 00 00
ON BE EF 03 06 00 BA D2 01 00 00 60 01 00
Get BE EF 03 06 00 19 D3 02 00 00 60 00 00
[Example return]
  00  00  01  00  02  00 
 [Off]  [On]  [Cool down]
Input Source Set COMPUTER IN1 BE EF 03 06 00 FE D2 01 00 00 20 00 00
COMPUTER IN2 BE EF 03 06 00 3E D0 01 00 00 20 04 00
HDMI BE EF 03 06 00 0E D2 01 00 00 20 03 00
S-VIDEO BE EF 03 06 00 9E D3 01 00 00 20 02 00
VIDEO BE EF 03 06...

Page 20

20
Names Operation Type HeaderCommand Data
CRC Action Type Setting Code
GAMMA Set #1 DEFAULT BE EF 03 06 00 07 E9 01 00 A1 30 20 00
#2 DEFAULT BE EF 03 06 00 97 E8 01 00 A1 30 21 00
#3 DEFAULT BE EF 03 06 00 67 E8 01 00 A1 30 22 00
#4 DEFAULT BE EF 03 06 00 F7 E9 01 00 A1 30 23 00
#5 DEFAULT BE EF 03 06 00 C7 EB 01 00 A1 30 24 00
#6 DEFAULT BE EF 03 06 00 57 EA 01 00 A1 30 25 00
#1 CUSTOM BE EF 03 06 00 07 FD 01 00 A1 30 10 00
#2 CUSTOM BE EF 03 06 00 97 FC 01 00 A1 30 11 00
#3 CUSTOM BE EF 03 06 00 67...