Hitachi Cp D31n Technical Manual
Here you can view all the pages of manual Hitachi Cp D31n Technical Manual. The Hitachi manuals for Projector are available online for free. You can easily download all the documents as PDF.
Page 11
11 RS-232C Communication (continued) Communicaion settings 1. Protocol 19200bps,8N1 2. Command format ("h" shows hexadecimal) Byte Number01 2 3456789101112 Command ActionHeader Data Header code Packet Data sizeCRC flagAction TypeSetting code LH LHLHLHLHLH Change setting to desired value [(cL)(cH)]. BEh EFh 03h 06h 00h(aL) (aH) 01h 00h (bL) (bH) (cL) (cH) Read projector internal setup value [(bL) (bH)].(aL) (aH) 02h 00h (bL) (bH) 00h 00h Increment setup value [(bL)(bH)] by 1.(aL) (aH) 04h...
Page 12
12 RS-232C Communication (continued) NOTE • Operation cannot be guaranteed when the projector receives an undefined command or data. • Provide an interval of at least 40ms between the response code and any other code. • The projector outputs test data when the power supply is switched ON, and when the lamp is lit. Ignore this data. • Commands are not accepted during warm-up. 3. Response code / Error code ("h" shows hexadecimal) (1) ACK reply : 06h When the projector receives the Set,...
Page 13
13 Command Control via the Network When the projector connects network, the projector can be controlled with RS- 232C commands from the computer with web browser. For details of RS-232C commands, refer to RS-232C Communication / Network command table (19). Connection 1. Turn off the projector and the computer. 2. Connect the projector's LAN port and the computer's LAN port with a LAN cable. Use the cable that fulfi lls the specifi cation shown in fi gure (Use CAT-5 or greater LAN Cable when...
Page 14
14 Communicaion Port The following two ports are assigned for the command control. TCP #23 TCP #9715 Configure the following items form a web browser when command control is used. Port Settings Network Control Port1 (Port: 23)Port openClick the [Enable] check box to open [Network Control Port1 (Port: 23)] to use TCP #23. Default setting is “Enable”. AuthenticationClick the [Enable] check box for the [Authentication] setting when authentication is required. Default setting is “Disable”. Network Control...
Page 15
15 Command Control via the Network (continued) Command control settings [TCP #23] 1. Command format Same as RS-232C communication, refer to RS-232C Communicaton command format. 2. Response code / Error code ("h" shows hexadecimal) Four of the response / error code used for TCP#23 are the same as RS-232C Communication (1)~(4). One authentication error reply (5) is added. (1) ACK reply : 06h Refer to RS-232C communication (12). (2) NAK reoly : 15h Refer to RS-232C communication (12). (3)...
Page 16
16 2. Response code / Error code ("h" shows hexadecimal) The connection ID is attached for the TCP#23's response / error codes are used. The connection ID is same as the sending command format. (1) ACK reply : 06h + ××h (××h : connection ID) (2) NAK reoly : 15h + ××h (3) Error reply : 1Ch + 0000h + ××h (4) Data reply : 1Dh + xxxxh + ××h (5) Authentication error reply : 1Fh + 0400h + ××h (6) Projector busy reply: 1Fh + ××××h + ××h When the projector is too busy to receives...
Page 17
17 This projector is equipped with NETWORK BRIDGE function. When the projector connects to the computer by LAN communicaton, an external device that is connected with this projector by RS-232C communication can be controlled from the computer as a network terminal. For details, see the 3.7 Controlling the external device via the projector(using the NETWORK BRIDGE function) - Network Guide. Connection 1. Connect the computer's LAN port and the projector's LAN port with a LAN cable. 2. Connect...
Page 18
18 Communication settings For communication setting, use the OPTION - SERVICE - COMMUNICATION menu. ( OPTION menu - SERVICE - COMMUNICATION in the User's Manual - Operating Guide ) Item Condition BAUD RATE 4800bps / 9600bps / 19200bps / 38400bps Data length 8 bit (fixed) PARITY NONE/ODD/EVEN Start bit 1 bit (fixed) Stop bit 1 bit (fixed) Transmission method HALF-DUPLEX/FULL-DUPLEX NOTE • For connecting the projector to your devices, please read the manual for each devices, and connect them...
Page 19
19 Names Operation Type HeaderCommand Data CRC Action Type Setting Code Power Set OFF BE EF 03 06 00 2A D3 01 00 00 60 00 00 ON BE EF 03 06 00 BA D2 01 00 00 60 01 00 Get BE EF 03 06 00 19 D3 02 00 00 60 00 00 [Example return] 00 00 01 00 02 00 [Off] [On] [Cool down] Input Source Set COMPUTER IN1 BE EF 03 06 00 FE D2 01 00 00 20 00 00 COMPUTER IN2 BE EF 03 06 00 3E D0 01 00 00 20 04 00 HDMI BE EF 03 06 00 0E D2 01 00 00 20 03 00 S-VIDEO BE EF 03 06 00 9E D3 01 00 00 20 02 00 VIDEO BE EF 03 06...
Page 20
20 Names Operation Type HeaderCommand Data CRC Action Type Setting Code GAMMA Set #1 DEFAULT BE EF 03 06 00 07 E9 01 00 A1 30 20 00 #2 DEFAULT BE EF 03 06 00 97 E8 01 00 A1 30 21 00 #3 DEFAULT BE EF 03 06 00 67 E8 01 00 A1 30 22 00 #4 DEFAULT BE EF 03 06 00 F7 E9 01 00 A1 30 23 00 #5 DEFAULT BE EF 03 06 00 C7 EB 01 00 A1 30 24 00 #6 DEFAULT BE EF 03 06 00 57 EA 01 00 A1 30 25 00 #1 CUSTOM BE EF 03 06 00 07 FD 01 00 A1 30 10 00 #2 CUSTOM BE EF 03 06 00 97 FC 01 00 A1 30 11 00 #3 CUSTOM BE EF 03 06 00 67...