GE Vivid 7 User Manual
Here you can view all the pages of manual GE Vivid 7 User Manual. The GE manuals for Ultrasound System are available online for free. You can easily download all the documents as PDF.
Page 511
Appendix Vivid7/Vivid7 PRO Users Manual497 FC092326-03 • Seamless data storage and report creation • Measurements are summarized in worksheets - individual results can be edited or deleted • User-assignable parameters User Interface • Easy-to-learn user interface with intelligent keyboard • Front panel with application-specific rotaries and push buttons for primary controls • Application-specific secondary controls available through slidebars operated by a four-way rocker • Slide pot TGC curve...
Page 512
Appendix 498Vivid7/Vivid7 PRO Users Manual FC092326-03 Image Management • TruAccess: ultimate workflow with instant access data 10S 4.0 - 12.0 MHz H4901PCS Linear Array 7L 3.2 - 7.5 MHz H40212LF 10L 4.0 - 11.0 MHz H40212LG 12L 5.0 - 11.5 MHz H40412LH M12L a6.0 - 13.0 MHz H40412LD i8L 5.0 - 8.0 MHz H45511NW i13L 8.0 - 13.0 MHz H45511NT Curved Array (Convex) 3.5C 2.4 - 5.0 MHz H4901PE 5C 3.6 - 8.0 MHz H40412A M7C 3.0 - 8.0 MHz H40412LC 8C 4.0 - 10.0 MHz H40412LJ E8C 4.0 - 10.0 MHz H40412LD Doppler 2D...
Page 513
Appendix Vivid7/Vivid7 PRO Users Manual499 FC092326-03 management • Next generation of DICOM image format: raw image DICOM incorporates raw image data information with all its data management flexibility into the image communication standard DICOM • 2D, CFM or TVI data at maximum framerate may be reviewed by scrolling or by running cineloops • Image Clipboard for stamp-size storage and review of stored images and loops • Built-in patient archive with images/loops, patient information,...
Page 514
Appendix 500Vivid7/Vivid7 PRO Users Manual FC092326-03 myocardium in ECG-triggered mode • Available in 2D Tissue harmonic imaging and Color Angio • Probe dependent: M3S, 3S, 5S Left Ventricular Contrast (LVC) 1 • Based on 2nd harmonic imaging optimized for visualization of contrast in LV • Probe dependent: M3S, 3S, 5S, 6T 1) Harmonic Imaging for supporting contrast agent imaging was developed by Schering. EchoPAC PC • EchoPAC PC adds connectivity and image analysis capability to Vivid 7/Vivid 7...
Page 515
Appendix Vivid7/Vivid7 PRO Users Manual501 FC092326-03 adjustment capabilities of TVI, TT, SRI and Strain imaging data Quantitative Contrast analysis Post processing on Contrast Harmonic images (2D and Angio data) • Time-Intensity Analysis: allows instant time-intensity calculation from up to eight regions of interest • Curve-fitting Analysis: for research studies of myocardial perfusion rates using contrast agents • Offline ECG triggering from Real time data • Arbitrary curved Anatomical M-Mode...
Page 516
Appendix 502Vivid7/Vivid7 PRO Users Manual FC092326-03 between the scanner and another DICOM device Peripherals (options) Internal peripherals • SVHS VCR • Full control from system panel • Frame grabber for playback • M&A package for video measurements • B/W video printer with control from system panel • Color video printer with control from system panel Exter nal • Ink-jet printer Physical Dimensions Cart • Low rolling resistance casters • Brakes on front casters • Direction of casters can be...
Page 517
Appendix Vivid7/Vivid7 PRO Users Manual503 FC092326-03 Electrical Specifications Safety • Built to meet the requirements of: • IEC 60601-1 (1988) • UL 2601-1 • The European Medical Devices Directive (MDD) 93/42/ EEC (CE Mark) • The Vivid 7/Vivid 7 PRO ultrasound unit is a Class I device, type CF, according to Sub-clause 14 of IEC 60601-1 (1988). • The Vivid 7/Vivid 7 PRO ultrasound unit meets the EMC requirements in EN 55011 (1991/1998) for Group 1. Class B (10 meters) Voltage (VAC)Frequency...
Page 518
Appendix 504Vivid7/Vivid7 PRO Users Manual FC092326-03 Probe/Application over view Probe Application 3S M3S 5S 7S 10S 7L 10L 12L M12L i8L i13L 3.5C 5C M7C 8C E8C Abdominal ++ ++++ Arterial + Cardiac +++++ ++ Carotid ++++ Coronary +++++ Exercise + + Fetal Heart a++++ ++ + LV Contrast +++ LVO Stress + MC Contrast + + + Octave SRI + Obstetrics a++ + Pediatric +++++ Pelvic + + + Q-Stress + + Real Time MC + Renal + + + + Small rodent + + + Q-Stress + + Transcranial + + Superficial + + + Only the applications...
Page 519
Appendix Vivid7/Vivid7 PRO Users Manual505 FC092326-03 Venous + + Probe Application 2D 6D 5T 6T 8T 9T PAMPTE Abdominal Arterial Cardiac + + + + Carotid + Coronary + Exercise Fetal Heart a LV Contrast + LVO Stress MC Contrast + + + Octave SRI Obstetrics a Pediatric + + Pelvic Q-Stress Real Time MC Only the applications marked with a “a” are approved for fetal use when appropriate probe is selected.Probe Application 3S M3S 5S 7S 10S 7L 10L 12L M12L i8L i13L 3.5C 5C M7C 8C E8C Only the applications marked...
Page 520
Appendix 506Vivid7/Vivid7 PRO Users Manual FC092326-03 Renal Small rodent Q-Stress Transcranial Superficial VenousProbe Application 2D 6D 5T 6T 8T 9T PAMPTE Only the applications marked with a “a” are approved for fetal use when appropriate probe is selected. CAUTIONGE recommends dedicated probes for use on humans only or animals only. Mark probes dedicated for animals only with special labels. If probes are interchanged between humans and animals, GE strongly recommends that the probes are...