•  Seamless data storage and report creation
•  Measurements are summarized in worksheets - individual 
results can be edited or deleted
• User-assignable parameters
User Interface
•  Easy-to-learn user interface with intelligent keyboard
•  Front panel with application-specific rotaries and push 
buttons for primary controls
•  Application-specific secondary controls available through 
slidebars operated by a four-way rocker 
•  Slide pot TGC curve...

Page 512

Appendix
498Vivid7/Vivid7 PRO Users Manual
FC092326-03
Image Management
•  TruAccess: ultimate workflow with instant access data 
10S 4.0 - 12.0 MHz H4901PCS
Linear Array
7L 3.2 - 7.5 MHz H40212LF
10L 4.0 - 11.0 MHz H40212LG
12L 5.0 - 11.5 MHz H40412LH
M12L
a6.0 - 13.0 MHz H40412LD
i8L 5.0 - 8.0 MHz H45511NW
i13L 8.0 - 13.0 MHz H45511NT
Curved Array (Convex)
3.5C 2.4 - 5.0 MHz H4901PE
5C 3.6 - 8.0 MHz H40412A
M7C 3.0 - 8.0 MHz H40412LC
8C 4.0 - 10.0 MHz H40412LJ
E8C 4.0 - 10.0 MHz H40412LD
Doppler
2D...

Page 513

Appendix
Vivid7/Vivid7 PRO Users Manual499
FC092326-03
management
•  Next generation of DICOM image format: raw image 
DICOM incorporates raw image data information with all its 
data management flexibility into the image communication 
standard DICOM
•  2D, CFM or TVI data at maximum framerate may be 
reviewed by scrolling or by running cineloops
•  Image Clipboard for stamp-size storage and review of 
stored images and loops
•  Built-in patient archive with images/loops, patient 
information,...

Page 514

Appendix
500Vivid7/Vivid7 PRO Users Manual
FC092326-03
myocardium in ECG-triggered mode
•  Available in 2D Tissue harmonic imaging and Color Angio
•  Probe dependent: M3S, 3S, 5S
Left Ventricular Contrast (LVC)
1 
•  Based on 2nd harmonic imaging optimized for visualization 
of contrast in LV
•  Probe dependent: M3S, 3S, 5S, 6T
1) Harmonic Imaging for supporting contrast agent imaging was 
developed by Schering.
EchoPAC PC
•  EchoPAC PC adds connectivity and image analysis 
capability to Vivid 7/Vivid 7...

Page 515

Appendix
Vivid7/Vivid7 PRO Users Manual501
FC092326-03
adjustment capabilities of TVI, TT, SRI and Strain imaging 
data
Quantitative Contrast analysis
Post processing on Contrast Harmonic images (2D and Angio 
data)
•  Time-Intensity Analysis: allows instant time-intensity 
calculation from up to eight regions of interest
•  Curve-fitting Analysis: for research studies of myocardial 
perfusion rates using contrast agents
•  Offline ECG triggering from Real time data
•  Arbitrary curved Anatomical M-Mode...

Page 516

Appendix
502Vivid7/Vivid7 PRO Users Manual
FC092326-03
between the scanner and another DICOM device
Peripherals (options)
Internal peripherals
• SVHS VCR
•  Full control from system panel
•  Frame grabber for playback
•  M&A package for video measurements
•  B/W video printer with control from system panel
•  Color video printer with control from system panel
Exter nal
• Ink-jet printer
Physical Dimensions
Cart
•  Low rolling resistance casters 
•  Brakes on front casters
•  Direction of casters can be...

Page 517

Appendix
Vivid7/Vivid7 PRO Users Manual503
FC092326-03
Electrical Specifications
Safety
•  Built to meet the requirements of:
• IEC 60601-1 (1988)
• UL 2601-1
•  The European Medical Devices Directive (MDD) 93/42/
EEC (CE Mark)
•  The Vivid 7/Vivid 7 PRO ultrasound unit is a Class I 
device, type CF, according to Sub-clause 14 of 
IEC 60601-1 (1988).
•  The Vivid 7/Vivid 7 PRO ultrasound unit meets the EMC 
requirements in EN 55011 (1991/1998) for Group 1. 
Class B (10 meters)
Voltage
(VAC)Frequency...

Page 518

Appendix
504Vivid7/Vivid7 PRO Users Manual
FC092326-03
Probe/Application over view
Probe
Application
3S M3S
5S
7S
10S
7L
10L
12L
M12L
i8L
i13L
3.5C
5C
M7C
8C
E8C
Abdominal ++ ++++
Arterial +
Cardiac +++++ ++
Carotid ++++
Coronary +++++
Exercise + +
Fetal Heart
a++++ ++ +
LV Contrast +++
LVO Stress +
MC Contrast  + + +
Octave SRI +
Obstetrics
a++ +
Pediatric +++++
Pelvic + + +
Q-Stress + +
Real Time MC +
Renal + + + +
Small rodent + + +
Q-Stress + +
Transcranial + +
Superficial + + +
Only the applications...

Page 519

Appendix
Vivid7/Vivid7 PRO Users Manual505
FC092326-03
Venous + +
Probe
Application
2D 6D
5T
6T
8T
9T
PAMPTE
Abdominal
Arterial
Cardiac + + + +
Carotid +
Coronary +
Exercise
Fetal Heart
a
LV Contrast +
LVO Stress
MC Contrast  + + +
Octave SRI
Obstetrics
a
Pediatric + +
Pelvic
Q-Stress
Real Time MC
Only the applications marked with a “a” are approved for fetal use when appropriate 
probe is selected.Probe
Application
3S M3S
5S
7S
10S
7L
10L
12L
M12L
i8L
i13L
3.5C
5C
M7C
8C
E8C
Only the applications marked...

Page 520

Appendix
506Vivid7/Vivid7 PRO Users Manual
FC092326-03
Renal
Small rodent
Q-Stress
Transcranial
Superficial
VenousProbe
Application
2D 6D
5T
6T
8T
9T
PAMPTE
Only the applications marked with a “a” are approved for fetal use when appropriate 
probe is selected.
CAUTIONGE recommends dedicated probes for use on humans only or 
animals only. Mark probes dedicated for animals only with 
special labels.
If probes are interchanged between humans and animals, GE 
strongly recommends that the probes are...