Page 41
GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL Chapter 1 - Introduction 1 - 3 1-2-2 Typical Users of the Service Manual • Service Personnel (installa tion, maintenance, etc.) • Hospital’s Service Personnel • Architectural Planners/Installation Planners (s ome parts of Chapter 2, Site Preparations) 1-2-3 Vivid 7 Models Covered by this Manual Table 1-3 Vivid 7 Models and Hardware/Software Compatibility sheet 1 of 3 MODEL NUMBER DESCRIPTION FRONT-END PROCESSORBACK-END...
Page 42
GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL 1 - 4 Section 1-2 - Service Manual Overview FC000760 VIVID 7 DIMENSION, MULTIDIMEN SIONAL RENDERING AND VOLUME (BT’05), 230 VAC FEP2(RFI) BEP3.2 v5.x FC000770VIVID 7 DIMENSION, MULTIDIMEN SIONAL RENDERING AND VOLUME (BT’05), 120 VAC FC000780VIVID 7 DIMENSION (BT’05), 230 VAC FC000790VIVID 7 DIMENSION (BT’05), 100-120 VAC FC000800 VIVID 7 PRO (BT’05), 230 VAC FC000810 VIVID 7 PRO (BT’05), 100-120 VAC FC000820 VIVID 7 DIMENSION...
Page 43
GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL Chapter 1 - Introduction 1 - 5 NOTE: When not otherwise specified, the contents in this manual applies to all Vivid 7 models. FC000340VIVID 7 PRO (BT’03), 100 - 120 VAC FEP1 (RFT) BEP2v3.1/v3.3 FC000330 VIVID 7 PRO (BT’03), 220 - 240 VAC FC000320 VIVID 7 (BT’03), 100 - 120 VAC FC000310 VIVID 7 (BT’03), 220 - 240 VAC FC000210VIVID 7 (BT’02), 100 - 120 VAC- Manufactured with either BEP1 or BEP2. - BEP2 may be used as FRU - BEP2...
Page 44
GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL 1 - 6 Section 1-2 - Service Manual Overview 1-2-4 Product Description 1-2-4-1 Overview of the Vivid 7 Ultrasound Scanner • Vivid 7 is a phased and linear array ultrasound im aging scanner. It also has provisions for analog input sources like ECG and phono, and a Doppler probe may be connected and used too. • Real Time 3D (RT 3D) was introduced as an option to VIVID 7 Dimension in 2004 (BT’04). • The unit can be used for: - 2D...
Page 45
GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL Chapter 1 - Introduction 1 - 7 1-2-4-1 Overview of the Vivid 7 Ultrasound Scanner (cont’d) Figure 1-1 Vivid 7 Major Components CRT MONITOR. (Discontinued 2007) OPERATOR PANEL B/W VIDEO PRINTER DVD or CD DRIVEMO DRIVE BRAKE PEDALS PARKING SLOT (UNITS WITHOUT 4D) PROBE CONNECTORS VCR or DVD RECORDER UPPER PANEL WITH STEREO LOUDSPEAKERS DOPPLER (PEDOF) CONNECTOR PATIENT I/O 21” LCD MONITOR - STANDARD FOR BT’08. - OPTION...
Page 46
GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL 1 - 8 Section 1-2 - Service Manual Overview 1-2-4-2 History - Hardware/Software Versions The contents in this sub-section has been moved to chapter 9. • For Front-End Processor Version 2, please refer to: 9-18-2 Hardware/Software Versions, Front- End Processor Version 2 (FEP2) on page 9-38 • For Front-End Processor Version 1, please refer to: 9-18-4 Hardware/Software Versions, Front- End Processor Version 1 on page 9-42 1-2-4-3...
Page 47
GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL Chapter 1 - Introduction 1 - 9 Section 1-3 Important Conventions 1-3-1 Conventions Used in Book 1-3-1-1 Model Designations. This manual covers the Vivid 7 scanners listed in Table 1-3 on page 1-3. 1-3-1-2 Icons Pictures, or icons, are used wh erever they will reinforce the prin ted message. The icons, labels and conventions used on the product and in the service information are described in this chapter. 1-3-1-3 Safety...
Page 48
GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL 1 - 10 Section 1-3 - Important Conventions 1-3-2 Standard Hazard Icons Important information will always be preceded by the exclamation point contained within a triangle, as seen throughout this chapter. In addition to text, several different graphical icons (symbols) may be used to make you aware of sp ecific types of hazards that could possibly cause harm. Even if a symbol isn’t used in this manual, it is included for your...
Page 49
GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL Chapter 1 - Introduction 1 - 11 1-3-3 Product Icons The following table describes the purpose and location of safety labels and other important information provided on the equipment. Table 1-6 Product Icons sheet 1 of 4 LABEL/SYMBOLPURPOSE/MEANINGLOCATION Identification and Rating Plate Manufacturers name and address Date of manufacture Model and serial numbers Electrical ratings Rear of console near power inlet Type/Class...
Page 50
GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL 1 - 12 Section 1-3 - Important Conventions Please refer to the Recycling instructions on the label located outside the Front End Card Rack’s Cover (Inside the unit), see Figure 1-20 on page 1-64 and Figure 1-23 on page 1-67. REAR OF CONSOLE Vivid 7 SCANNERS PRODUCED AFTER SEPTEMBER 2004: Vivid 7 SCANNERS PRODUCED AFTER SEPTEMBER 2004: “TESTED AND PRODUCTION MONITORED BY TUV PRODUCT SERVICE NRTL WITH RESPECT TO ELECTRICAL...