GE Frame 5 Service Manual
Here you can view all the pages of manual GE Frame 5 Service Manual. The GE manuals for Gas Turbines are available online for free. You can easily download all the documents as PDF.
Page 41
37 A .2) Example 2 – Hot Gas Path Factored Starts Calculation A 7E.03 user has accumulated operating data for the past year of operation. This data shows number of trips from part, base, and peak load, as well as peaking-fast starts. The user would like to calculate the total number of factored starts in order to plan the next HGP outage. Figure 43 is used to calculate the total number of factored starts as shown below. Operational history: Normal cycles Peaking starts with normal shutdowns...
Page 42
38 B) Examples – Combustion Maintenance Interval Calculations (reference Figures 40 and 41) DLN 1 Peak Load with Power Augmentation +50F Tfire Increase Factored Hours = Ki * Afi * Api * ti = 34.5 Hours Hours Maintenance Factor = (34.5/6)5 .8 Where Ki =2.34 Max(1.0, exp(0.34(3.50-1.00))) WetAfi =1.00 Natural Gas FuelApi =2.46 exp(0.018(50)) Peak Loadti =6.0 Hours/Start Factored Starts = Ki * Afi * Ati * Api * Asi * Ni = 17.4 Starts Starts Maintenance Factor = (17.4/1)17 .4 Where Ki =2.77 Max(1.0,...
Page 43
39 Reliability: Probability of not being forced out of service when the unit is needed — includes forced outage hours (FOH) while in service, while on reserve shutdown and while attempting to start normalized by period hours (PH) — units are %.Reliability = (1-FOH/PH) (100) FOH = total forced outage hours PH = period hours Availability: Probability of being available, independent of whether the unit is needed – includes all unavailable hours (UH) – normalized by period hours (PH) – units are %:...
Page 44
40 D) Estimated Repair and Replacement Intervals (Natural Gas Only) Repair/replace intervals reflect current production hardware, unless otherwise noted, and operation in accordance with manufacturer specifications. Consult previous revisions of GER 3620 or other unit- specific documentation for estimated repair/replacement intervals of previous generation gas turbine models and hardware. Consult your GE service representative for further information. MS3002K Parts Repair IntervalReplace Interval...
Page 45
41 7E .03 (7) Repair IntervalReplace Interval (Hours) Replace Interval (Starts) Combustion Liners Cl 3 (Cl) / 5 (Cl) (1) 5 (Cl) Caps Cl 3 (Cl) 5 (Cl) Transition Pieces Cl 4 (Cl) / 6 (Cl) (5) 6 (Cl) Fuel Nozzles Cl 2 (Cl) / 3 (Cl) (6) 3 (Cl) Crossfire Tubes Cl 1 (Cl) 1 (Cl) Crossfire Tube Retaining Clips CI 1 (CI) 1 (CI) Flow Divider (Distillate) Cl 3 (Cl) 3 (Cl) Fuel Pump (Distillate) Cl 3 (Cl) 3 (Cl) Stage 1 Nozzles HGPI 3 (HGPI) 3 (HGPI) Stage 2 Nozzles HGPI 3 (HGPI) 3...
Page 46
42 6F .03 Repair IntervalReplace Interval (Hours) Replace Interval (Starts) Combustion Liners CI2 (CI) 2 (CI) Caps CI3 (CI) 2 (CI) Transition Pieces CI3 (CI) 2 (CI) Fuel Nozzles CI2 (CI) 2 (CI) Crossfire Tubes CI1 (CI) 1 (CI) Crossfire Tube Retaining Clips CI 1 (CI) 1 (CI) End Covers CI 4 (CI) 2 (CI) Stage 1 Nozzles HGPI2 (HGPI) 2 (HGPI) Stage 2 Nozzles HGPI2 (HGPI) 2 (HGPI) Stage 3 Nozzles HGPI3 (HGPI) 3 (HGPI) Stage 1 Shrouds HGPI2 (HGPI) 2 (HGPI) Stage 2 Shrouds HGPI2 (HGPI) 2 (HGPI) Stage 3...
Page 47
43 9F .03 Repair IntervalReplace Interval (Hours) Replace Interval (Starts) Combustion Liners Cl 2 (Cl) 3 (Cl) Caps Cl 2 (Cl) 3 (Cl) Transition Pieces Cl 2 (Cl) 3 (Cl) Fuel Nozzles Cl 2 (Cl) (1) 3 (Cl)(1) Crossfire Tubes Cl 1 (Cl) 1 (Cl) Crossfire Tube Retaining Clips CI 1 (CI) 1 (CI) End Covers CI 2 (Cl) 3 (Cl) Stage 1 Nozzles HGPI 2 (HGPI) 2 (HGPI) Stage 2 Nozzles HGPI 2 (HGPI) 2 (HGPI) Stage 3 Nozzles HGPI 3 (HGPI) 3 (HGPI) Stage 1 Shrouds HGPI 2 (HGPI) 2 (HGPI) Stage 2...
Page 48
44 Compressor 15th, 16th, 17th Stag e Compressor 0-6th Stage 24.5° 24.5° 24.5° 24.5° 99.5° 204.5° 9.8° 100.5° 170.2° 10.5° 100.5° 160.5° 9.73° 189.73° 12° 102° 155° 24.5° 1st Stg. LE1st Stg. TE2nd Stg. LE2nd Stg. TE3r d Stg. LE- Turbine Primary Inspection Access (Normal Inspection) Secondary Inspection Access (Additional Stators and Nozzles) Figure E-1 . Borescope inspection access locations for 6F machines Compressor 14th, 15th, 16th Stag e Compressor 0-5th Stage 25° 25° 25° 66° 13° 15° 151° 66°...
Page 49
45 F) Turning Gear/Ratchet Running Guidelines Scenario Turning Gear (or Ratchet) Duration Following Shutdown: Case A.1 – Normal. Restart anticipated for >48 hours Until wheelspace temperatures
Page 50
46 G) B/E- and F-class Gas Turbine Naming Class PlatformModel DesignationPrior model seriesPrior model number Prior names F-class 6F - MS6001(FA)6101(FA) 6FA.01 6FA 6F.03 6111(FA) 6FA.03 6FA+e - --6F Syngas- 7F - MS7001(FA)7221(FA) 7FA.01 7FA - 7231(FA) 7FA.02 7FA+ 7F.03 7241(FA) 7FA.03 7FA+e 7F.04 - 7FA.04 - - MS7001(FB) 7251(FB) 7FB.01 - - --7F Syngas- 9F - MS9001(FA)9311(FA) 9FA.01 9FA - 9331(FA) 9FA.02 9FA+ 9F.03 9351(FA) 9FA.03 9FA+e - MS9001(FB)9371(FB) 9FB.01 - - - 9FB.02 - 9F.05 - 9FB.03 -...