    • EXIT— press once to use the Quick Exit feature.
    • AWAY—press once to arm to Level 3—AWAY.
    Note  Macro Keys should not be 
    programmed to disarm the 
    system.Your installer can also program these buttons to perform a system command different from those 
    described. For example, instead of entering the command 2 + CODE + 4 + 6 (arm to STAY with 
    No Delay and Latchkey), your installer can program one of the macro keys to perform the task 
    with just one press. Check with your installer for more information.
    System 
    InformationThere is information about your system that is useful to know. This includes the factory code, the 
    system number, the system level, and software version.
    After identifying the information for your system, make a note of it in the “Appendix A: User 
    Sheets”.
    
    						
    							Concord  4 Series Security Systems32
    • The Viewing Event History mode will exit automatically after one minute of inactivity OR 
    when an alarm occurs.
    The following table is a comprehensive list of displayed events and their associated details (parti-
    tion, current arming level, zone, bus unit number, source and user). If details are displayed for an 
    event an X will appear in the table.
    • Partitions are displayed as P1 - P6, depending on which partition the event occurred.
    • Current Arming Level will display Lx, where x is the current arming level of the event.
    • Zone will display Zx, where x is the zone of the event.
    • Bus Unit Number will display Bx, where x is the unit number of the Bus device.
    • Source will display Sxxx, where xxx is the source number in the event (see table on source 
    numbers for more information).
    • User will display Uxxx, where xxx is user number in the event (see table on user numbers for 
    more information).
    EventDisplayPartitionCurrent 
    Arming 
    LevelZoneBus Unit 
    NumberSource 1User 2
    AC Power Failure AC POWER FAILURE X
    AC Power Restoral AC POWER RESTORAL X
    Antenna Tamper RCVR TAMPER X X
    Arming Level Change 
    3ARM LEVEL CHANGE X X X
    Auto Force Arm  AUTO FORCE ARM X X X
    Auto Phone Test AUTO PHONE TEST X
    Auxiliary Panic AUXILIARY PANIC X X
    Auxiliary Panic Cancelled AUXLRY CANCELLED X X
    Bus Cover Tamper BUS TAMPER X X
    Bus Failure BUS FAILURE X X
    Closing Report CLOSING REPORT X X X X
    CPU Back In Service BACK IN SERVICE X X
    CPU Battery Restoral BATTERY RESTORED X
    CPU Low Battery CPU LOW BATTERY X
    Daylight Savings Time Adjust DAYLIGHT SAVINGS
    Download Session Entry DOWNLOAD ENTRY
    Download Session Exit DOWNLOAD EXIT
    Duress Alarm DURESS X X
    Event Buffer Viewing Entry EVENT VIEW ENTRY X X X
    Event Buffer Viewing Exit EVENT VIEW EXIT X X X
    Fire Panic FIRE PANIC X X
    Fire Panic Cancelled FIRE CANCELLED X X
    Force Arm FORCE ARM X X X
    Installer Programming Entry INST PROG ENTRY X X X
    Installer Programming Exit INST PROG EXIT X X X
    Lost Event (buffer overflow) LOST EVENT
    Main Unit Tamper MAIN UNIT TAMPER X
    Memory Clear MEMORY CLEAR
    Memory Failure MEMORY FAILURE
    No Activity Alarm ACTIVITY ALARM X 
    						
    							Concord  4 Series Security Systems33
    User information is shown in the following table.
    No Activity Cancelled ACTIVITY CANCEL X X
    Opening Report OPENING REPORT X X X X
    Phone Failure PHONE FAILURE X
    Phone Line Test Failure PHONE LINE FAIL X
    Phone Line Test Restoral PH LINE RESTORED X
    Phone Test PHONE TEST X X X
    Police Panic POLICE PANIC X X
    Police Panic Cancelled CANCELLED X X
    Receiver Failure RECEIVER FAILURE X X
    Receiver Jam RECEIVER JAM X X
    Recent Closing RECENT CLOSING X X X
    Remote Access Lockout REMOTE LOCKOUT
    Repeater Jam REPEATER JAM X X
    Repeater Jam Restoral JAM RESTORED X X
    Siren Trouble SIREN TROUBLE
    Swinger Shutdown SWINGER X X
    Time Change TIME CHANGE
    Touchpad Tamper TOUCHPAD TAMPER X X
    Touchpad Tamper Cancelled TP TAMPER CANCEL X X
    Two Trip Error TWO TRIP ERROR X X
    User Programming Entry USER PROG ENTRY X X X
    User Programming Exit USER PROG EXIT X X X
    Zone Alarm ALARM X X
    Zone Alarm Cancel ALARM CANCELLED X X
    Zone Alarm Restoral ZONE RESOTRED X X
    Zone Battery Restoral BATTERY RESTORED X X
    Zone Bypass BYPASSED X X X
    Zone Low Battery LOW BATTERY X X
    Zone Supervisory SUPERVISORY X X
    Zone Tamper TAMPER X X
    Zone Trouble TROUBLE X X
    Zone Trouble Restoral TROUBLE RESTORED X X
    Zone Unbypass UNBYPASSED X X X
    1 Source information is shown only if the information was available when the event was buffered.2 User information is shown only if the information was available when the event was buffered.3 Line two of the display also contains “P-C” where P is the previous arming level and C is the current arming level.
    EventDisplayPartitionCurrent 
    Arming 
    LevelZoneBus Unit 
    NumberSource 1User 2
    Detail Screen DisplayUser
    U001 - U096 Wireless Touchpad or Keyfob 
    						
    							Concord  4 Series Security Systems34
    Source information is shown in the following table.
    Using a 
    Touchtone 
    Phone to 
    Operate Your 
    SystemYour system may be equipped with an option that allows system operation from a Touchtone 
    phone, on or off the premises. 
    This option enables programmed text to be spoken through the phone and/or broadcast through 
    interior speakers. Except for custom words, the voice speaks the text that appears on alphanu-
    meric touchpads in the system.
    Phone Command Prefix
    What distinguishes a call to the panel from any other out-going or incoming call is the use of the 
    Phone Command Prefix:
    • In the case of on-site operation, if the Phone Command Prefix is dialed first (within 5 seconds 
    of picking up the phone), the panel waits for a valid access code or command.
    • If the system is being accessed remotely, the Phone Command Prefix is used in conjunction 
    with the access code.
    The prefix is usually 
    #, but can be changed to * by the installer. If your prefix has been changed, 
    use 
    * as the first key you press instead of #.
    Accessing the System from Off-site
    To access the system from off-site, the system needs to recognize two things about the call:
    • The panel needs to recognize that it should answer the phone.
    • The panel needs to recognize that the code entered has the authority to operate the system 
    from off-site.
    U600 - U829 Regular User Codes 000 - 229
    U830 - U835 Partition Master Codes 1 - 6
    U838 - U843 Partition Duress Codes 1 - 6
    U846 System Master Code
    U847 Installer Code
    U848 Dealer Code
    U849 AVM Code
    U850 Quick Arming
    U851 Keyswitch Arming
    U852 System
    Detail Screen DisplaySource
    S00 Premise Phone
    S01 Phone During Conversation
    S02 Remote Phone
    S06 Auto Stay Arming
    S07 Automation Module
    S08 Keyswitch Arming Zone
    S09 System
    S1xx (xx = Zone Number) Keychain Touchpad 
    S1xx (xx = Zone Number) Wireless Touchpad 
    S3xx (xx = Bus Unit Number) Alphanumeric Touchpad
    S6xx (xx = Bus Unit Number) Fixed Display Touchpad
    Detail Screen DisplayUser 
    						
    							Concord  4 Series Security Systems35
    When using a cellular phone to operate the system, follow the off-site operating instructions.
    How the Panel Answers the Phone
    When you call the panel, it needs to recognize that it should answer the incoming call. This is 
    accomplished by one of two methods: 
    • Ring-Hang-Ring method
    • Twelve-Ring method
    Ring-Hang-Ring Method
    You can use this method if there is no chance that an answering machine or person will pick up 
    the call on the first ring.
    1. Call the panel. (In most cases this is the same number as the regular phone.) 
    2. Let the phone ring once, then hang up.
    3. Wait between 8 and 30 seconds, then call the system again. This time the panel will answer 
    (“System hello,”) on the first ring.
    4. Enter
     # (your designated Phone Command Prefix).
    5. Enter your access 
    CODE. You hear a short status message, such as, “System is OK.” 
    6. Proceed with system commands.
    Twelve-Ring
    You can use this method if there is no chance that an answering machine or person will pick up 
    the call before the twelfth ring.
    1. Call the panel and let the phone ring. The panel will answer “System hello” after the twelfth 
    ring.
    2. Enter
     # (your designated Phone Command Prefix).
    3. Enter your access 
    CODE. You hear a short status message, such as, “System is OK.” 
    4. Proceed with system commands.
    Codes with Remote Access Capability
    The ability to access the system from off-site is determined by a code attribute (see “Assigning 
    Code Attributes”).
    Check the User Sheets in Appendix A to see which access codes have the ability to operate the 
    system from off-site.
    Touchtone Phone System Operation
    Phone operation of your system involves 2 steps: 
    Step 1.  Use a Touchtone phone to access the system.
    Local Phone Access Pick up the phone. Within 5 seconds of picking up the phone receiver, 
    enter # (or 
    *).
    Remote Phone Access Use the Ring-Hang-Ring or the Twelve-Ring method to get the system 
    to answer the call.
    Then enter 
    # (or *) + CODE  
    						
    							Concord  4 Series Security Systems36
    Activating a Police Panic Alarm
    Your system can be set up so you can activate a Police panic alarm from an on-site Touchtone 
    phone. If your system is set up for this:
    • Press the 
    * repeatedly, regardless of your phone command prefix key.
    • Do not wait more than two seconds between key presses. Continue pressing 
    * even if you 
    hear the system voice interrupt with a system status.
    Off-site Touchtone phones cannot activate this alarm.
    Step 2. Enter the command.
    Disarm the system
    # + 1 + CODE
    Arm to Level 2*# + 2 + CODE
    Arm to Level 3*# + 3 + CODE
    Send a Police panic alarm * + * + * + * + * + *(Available from on-site only.)
    Arm system with No Delay*
    # + 2 + CODE + 4 or
    # + 3 + CODE + 4 
    Arm to enable Latchkey*
    # + 2 + CODE + 6 or
    # + 3 + CODE + 6 
    Arm system with exit lights off*
    # + 2 + CODE + 0 or
    # + 3 + CODE + 0 
    Bypass a sensor
    Indirectly: Arm system + 
    # + #
    Directly: # + # + CODE + Sensor Number
    Arm silently*
    # + 5 + 2 + CODE or
    # + 5 + 3 + CODE
    Turn all lights on/off# + 0 + 0
    Turn specific lights on/off# + 0 + Light number (1–9)
    Cancel an accidental alarm
    # + 1 + CODE or # + CODE
    Check the system status# + * for short status
    # + ** for full status
    Turn Chime on/off
    # + 7 + 1
    Turn Energy Saver on/off# + 7 + 2
    Disable local phone access# + 7 + 3 (on-site only) or
    Wait 5 seconds after picking up a local phone.
    Check alarm memory
    # + 7 + 6
    Activate Outputs# + 7 + 7 + Output number (1–6)
    * If Quick Arm feature is on, access code is not required.  See page 6 for more information. 
    						
    							Concord  4 Series Security Systems37
    Phone Questions?
    What if someone calls while I’m operating the panel?
    If the phone rings while you’re using it to operate the system, you’ll hear one long beep for each 
    ring from interior speakers and phones. You can answer the call by simply hanging up on the sys-
    tem, then answering the call as you normally would.
    You’ll have to initiate another session to resume system operation.
    Can I control the system while I’m talking on the phone?
    No.
    How do I perform other phone operations without commanding my security system?
    You can use your phone for transactions such as banking from home by temporarily disengaging 
    phone control to your security system. The following procedure will work for one call at a time.
    
    						
    							Concord  4 Series Security Systems38
    4. Disarm to Level 1—Off to exit Test Mode.
    Phone Communication Test
    The purpose of this test is to verify communication between the central monitoring station and 
    your system.
    Most phone tests take only a few minutes, however, your system will try for up to 15 minutes to 
    establish a connection if necessary.
    DeviceTest ProcedureTouchpad Result(s)
    Touchpad Trip a:
    Police panic alarm,
    Fire panic alarm, and 
    Auxiliary panic alarm.
    • Touchpad Panic POLICE OK
    • Touchpad Panic FIRE OK
    • Touchpad Panic AUXILIARY OK
    • POLICE PANIC OK
    •FIRE PANIC OK
    • AUXILIARY PANIC OK
    Wireless Touchpad Press the Bypass key.• Zones nn OK
    • TOUCHPAD nn OK
    Keychain Touchpad
    Press and hold the Lock   and Unlock   buttons 
    simultaneously for 3 seconds.• Zones nn OK
    • TOUCHPAD nn OK
    Press and hold the Star   and Light   buttons 
    simultaneously for 3 seconds.• Touchpad Panic AUXILIARY OK
    • AUXILIARY PANIC OK
    Panic button Press and hold the appropriate panic button(s) for 3 
    full seconds.• Zones nn OK
    •SENSOR nn OK
    Door/window sensor Open the secured door or window.• Zones nn OK
    •SENSOR nn OK
    Smoke detector Press and hold the test button until the system sounds 
    transmission beeps.• Zones nn OK
    •SENSOR nn OK
    Motion detector Avoid the motion detector view for 5 minutes, then 
    enter its view.• Zones nn OK
    •SENSOR nn OK
    Rate-of-Rise Heat Detec-
    tor (Not UL investigated)Rub your hands together until warm, then place one 
    hand on the detector for 30 seconds.• Zones nn OK
    •SENSOR nn OK
    Shock sensor
    (Not UL investigated)Tap the glass twice, away from the sensor.  Wait at 
    least 30 seconds before testing again.• Zones nn OK
    •SENSOR nn OK
    Phone Interface and 
    Voice ModuleActivate a Police panic by accessing the system using 
    the phone and pressing 
    * + * + * + * + * + *.• POLICE PANIC OK
    Glass guard sensor
    (Not UL investigated)Tap the glass 3 or 4 inches from the sensor.• Zones nn OK
    •SENSOR nn OK
    Freeze sensor
    (Not UL investigated)Apply an ice cube wrapped in plastic to the sensor. Do 
    not allow the sensor to get wet.• Zones nn OK
    •SENSOR nn OK
    • If you need more time to complete testing, restart the timer by pressing 
    8 + CODE + 3.
    • Check to see that all sensors have been tested by pressing 
    *. Touchpads display a list of untested sensors.
    • You will know that you have finished testing when touchpads display, “SENSOR TEST OK” or “ZONES ALL 
    TESTED.” 
    						
    							Concord  4 Series Security Systems39
    
    						
    							Concord  4 Series Security Systems40
    Common Questions and Answers
    Q. I can’t arm my system.
    A. Try the following:
    • If arming to Level 2—STAY or Level 3—AWAY, make sure all monitored perimeter doors 
    and windows are closed.
    • Press 
    * for a system status and for clues to the problem.
    • Call the installer.
    Q. I cannot bypass a sensor: my alphanumeric touchpad displays “INVALID” and my fixed dis-
    play touchpad sounds a single, long beep.
    A. Possible explanations include:
    • The sensor you’re trying to bypass may not be active in the current arming level. For exam-
    ple, an interior motion detector will not be active in Level 2—STAY.
    • You may be trying to bypass a 24-hour sensor that cannot be bypassed, such as a smoke 
    detector.
    • Your access code has not been assigned the direct bypassing attribute. See “Assigning the 
    Direct Bypassing Attribute”.
    Q. I can’t arm my system to Level 3—AWAY.
    A. If a delay door is open while you’re trying to arm the system to Level 3 or a delay door was 
    not activated after the arming attempt, the system will arm to Level 2 instead. Close the delay 
    door, arm the system to Level 3, then exit through a delay door.
    Phone Issues
    Q. How do I disable my system long enough to retrieve messages from work or to do banking 
    over the phone?
    A. Solutions include:
    • Disengage the security system from local phone control by entering 
    # + 7 + 3. The system 
    responds by returning a dial tone.
    • Pick up the phone receiver and wait 5 seconds before dialing any numbers. After the 5 second 
    period, the system disables local phone control and ignores phone commands.
    Lighting Issues
    Q.My lights don’t come on automatically as they’ve been programmed to do.
    A.Try the following:
    • Does the lamp have a working bulb?
    • Is the lamp plugged in at a working outlet that is not controlled by a light switch?
    • Is the lamp plugged in to a lamp module? 
    • Make sure that you’ve attached the correct time schedule as described in “Advanced Light 
    Control”.
    • Check to see that you’ve set up the time schedule correctly as described in “Creating Time 
    Schedules”.
    • Check the User Sheets in Appendix A to see in which partition the light is set up to be active. 
    						
    All GE manuals Comments (0)