Page 41
AMX-4+ OPERATION GE Healthcare (MODEL 2169360, 2236420 & 2275938 SERIES) REV 15 om 2166913-1EN 7-4 Table 7-2 SAMPLE CHART FOR TECHNIQUE ACCURACY TESTSField size indicatorEvery year (Refer to Appendix 3, Direction 2173227-100, AMX-4+ Periodic Maintenance) Rotational detent Every year (Refer to Section 3-4, Direction 2173224-100, AMX-4+ Functional Check) Exposure tone is audible and X-ray on indicators light up when handswitch depressed to expose positionEvery year Auxiliary items (battery charger, HV...
Page 42
AMX-4+ OPERATION GE Healthcare (MODEL 2169360, 2236420 & 2275938 SERIES) REV 15 om 2166913-1EN 8-1 SECTION 8 MESSAGES ON DISPLAY Two kinds of messages can appear on the message display on the control cover: status messages and error messages. Status messages simply inform you of the operating condition of the AMX-4+, and look something like this. Another type of message, called an error message, may appear should a problem occur with the equipment . An error message looks something like this. Note...
Page 43
AMX-4+ OPERATION GE Healthcare (MODEL 2169360, 2236420 & 2275938 SERIES) REV 15 om 2166913-1EN 8-2 Status MessagesDescription AUTO CAL LIMITIf this message displays, the unit is at its automatic calibration limit . A service call is recommended to ensure accurate technique and radiographic results. Exposures are not inhibited. BATTERY TOO HIGH VOLTAGE RECOVERY IS REQUIREDThis message may appear when attempting to take a high technique exposure immediately after removing the unit from charge....
Page 44
AMX-4+ OPERATION GE Healthcare (MODEL 2169360, 2236420 & 2275938 SERIES) REV 15 om 2166913-1EN 8-3 Status Messages Description READY FOR X-RAYThe prep cycle has successfully completed, and an exposure may be taken within the next 30 seconds. (If an exposure is attempted after 30 seconds, the prep cycle must be repeated.) RECHARGE IMMEDIATELY - X-RAY INHIBITEDThe estimated usable battery capacity is near 0%. No more exposures may be taken. Although charge is too low to complete an x-ray exam, youll...
Page 45
AMX-4+ OPERATION GE Healthcare (MODEL 2169360, 2236420 & 2275938 SERIES) REV 15 om 2166913-1EN 9-1 SECTION 9 SYMBOLS 9-1 IEC Classif ication In accordance with International Safety Standard IEC 601, the AMX-4+ Mobile X-ray Unit is classif ied as Type B Equipment , Class I Equipment , Internally Powered Equipment , Ordinary Equipment and continuous operation. Type B Equipment provides an adequate degree of protection against electric shock, in particular regarding: • allowable leakage current , •...
Page 46
AMX-4+ OPERATION GE Healthcare (MODEL 2169360, 2236420 & 2275938 SERIES) REV 15 om 2166913-1EN 9-2 Indicates non-ionizing radiation is present . Indicates radiographic control. Indicates ionizing radiation is present . X-ray emission. X-ray tube head is emitting X-rays. Take adequate precautions to prevent the possibility of any persons carelessly, unwisely, or unknowingly exposing themselves or others to radiation. Battery power on. This does not apply mains voltage. Battery power off. This does not...
Page 47
AMX-4+ OPERATION GE Healthcare (MODEL 2169360, 2236420 & 2275938 SERIES) REV 15 om 2166913-1EN 9-3 Control for indicating radiation f ield by using light . Collimator blades closed. The controlled blades are shown in thicker lines. Collimator blades open. The controlled blades are shown in thicker lines. Alternating Current . Indicates equipment that is suitable for alternating current only. This symbol indicates that the waste of electrical and electronic equipment must not be disposed as unsorted...
Page 48
AMX-4+ OPERATION GE Healthcare (MODEL 2169360, 2236420 & 2275938 SERIES) REV 15 om 2166913-1EN 10-1 SECTION 10 OPTIONS 10-1 Dose Area Product (DAP) Meter Full f ield ion chamber with an integral display unit . The display unit contains electronics controlling total dose area product , system reset and system test . • Provides easy to read real time information on patient dose. • Allows for simple manual transcription of this information into patient records. 10-2 Mobil-AIDTM Automatic Exposure Control...
Page 49
AMX-4+ OPERATION GE Healthcare (MODEL 2169360, 2236420 & 2275938 SERIES) REV 15 om 2166913-1EN 11-1 SECTION 11 ENVIRONMENTAL CONDITIONS Table 11-1 ENVIRONMENTAL CONDITIONS System operating environmental temperature15°C to 38°C / 59°F to 100°F Storage environmental temperature-40°C to 60°C / -40°F to 140°F Operating ambient humidity10% to 80% relative humidity, non-condensing Non-operating ambient humidity5% to 95% relative humidity, non-condensing Operating ambient atmospheric pressure106.2 kPa down to...
Page 50
AMX-4+ OPERATION GE Healthcare (MODEL 2169360, 2236420 & 2275938 SERIES) REV 15 om 2166913-1EN 11-2 This page intentionally left blank.