Flir ThermovisionMSeries Operators Manual
Here you can view all the pages of manual Flir ThermovisionMSeries Operators Manual. The Flir manuals for Thermovision are available online for free. You can easily download all the documents as PDF.
Page 61
432-0003-00-10 Rev 150 — M-Series Operator’s Manual 59 M-Series IP Interface and PC Operations The system displays a warning as it restarts the network: When the IP address is changed, the browser window opened under the old IP address is no longer valid. Type the new static IP address into the browser address field, or return to Network (Win 7/Vista) or My Network Places (Win XP) to find the camera. UPnP broadcast is never disabled for M-Series cameras, even when using a static IP address. When the...
Page 62
M-Series IP Interface and PC Operations 60432-0003-00-10 Rev 150 — M-Series Operator’s Manual Changing the IP Address of the JCU The JCU communicates through the Ethernet IP protocol just like the M-Series camera does. Each JCU is configured by default to obtain an IP address dynamically from the system. On the JCU, the IP address is displayed by pressing the COLOR button and puck at the same time. The IP is displayed for 3 seconds and then the display returns to the camera name or other the state...
Page 63
432-0003-00-10 Rev 150 — M-Series Operator’s Manual 61 M-Series IP Interface and PC Operations Custom Network Applications Programmers/Integrators In more advanced/sophisticated installations where other devices such as radars are present on the network, the use of a PC allows more complicated configuration, flexibility and customization. This interface is primarily intended to give installers, dealers or even system integrators direct access to low-level configuration options and to the actual...
Page 64
M-Series IP Interface and PC Operations 62432-0003-00-10 Rev 150 — M-Series Operator’s Manual Command Strings For programmers and integrators, the actual command strings that are sent back and forth with the camera are displayed in the Command Strings fields at the bottom of the M-Series control page. The transmitted commands are displayed in the TX field and the received commands are displayed in the RX field. The commands sent back and forth are part of a communication protocol known as the FLIR...
Page 65
432-0003-00-10 Rev 150 M-Series Operator’s Manual 63 CHAPTER 6M-Series Reference Information Introduction This chapter includes a glossary of acronyms, a list of symbols used in on-screen display, and a number of lists and tables that summarize system information and show how features vary by camera model. It also includes a set of tips for troubleshooting issues. Acronyms Table 6.1 lists each acronym that is used in this manual and its meaning. TABLE 6.1 Acronyms Acronym/Term Definition AGC...
Page 66
M-Series Reference Information 64432-0003-00-10 Rev 150 — M-Series Operator’s Manual HFoV Horizontal Field of View ICD Interface Control Document IECInternational Electrotechnical Commission IEEEInstitute of Electrical and Electronics Engineers IP Internet Protocol IR Infrared or thermal JCU Joystick Control Unit LCD Liquid Crystal Display MFD Multifunction display NMEANational Marine Electronics Association NTSC National Television System Committee PAL Phase Alternating Line P/T Pan/Tilt PoE Power...
Page 67
432-0003-00-10 Rev 150 — M-Series Operator’s Manual 65 M-Series Reference Information List of Icons Table 6.2 lists every icon that may display on the screen during various operations, with a brief description of its meaning. Some icons display permanently and some only display briefly. The display of some icons is affected by settings on the Symbology Menu (see page 35). The last four icons in this table display only on the camera model with stabilization. TABLE 6.2 Video Display Icons Icon Name...
Page 68
M-Series Reference Information 66432-0003-00-10 Rev 150 — M-Series Operator’s Manual Icons Used with Mechanical Stabilization Lock Indicates that Point Mode is enabled and pan motion is not stabilized. Lock Off Indicates that Point Mode is disabled and pan motion is stabilized. Stabilization Off Indicates the stabilization setting, which improves camera image stability, has been disabled. This icon remains on the screen. Stabilization On Indicates the stabilization setting, which improves camera...
Page 69
432-0003-00-10 Rev 150 — M-Series Operator’s Manual 67 M-Series Reference Information System Specifications Table 6.3 lists details about physical characteristics, power usage, and environmental features of your M-Series camera. TABLE 6.3 Specifications Physical Characteristics Camera Size 17.8 cm (7 in) diameter by under 29.2 cm (11.5 in) tall Camera Weight Under 5.4 kg (12 lb), depending on the camera model Joystick Size 9.1 X 14.2 X 8.13 cm (3.6 X 5.6 X 3.2 in) 3.17 cm (1.25 in) above platform...
Page 70
M-Series Reference Information 68432-0003-00-10 Rev 150 — M-Series Operator’s Manual Feature Comparison of M-Series Models The following table lists each M-Series model and its supported features. Each model is available in four variations, identified by a unique part number: •