Page 11

432-0003-00-12 Rev 140 — M-Series Installation Guide 9
 Installing M-Series Systems
Camera Video Options
The M-Series gimbal assembly has either one or two video cables:
• The cable labeled IR is for the composite—also known as analog—video 
signal from the thermal (infrared) camera. This is the only cable on single 
payload cameras.
• On dual payload models, the cable labeled VIS/IR is for video from either the 
thermal camera or the DLTV camera. You use the JCU to determine which 
output displays. 
The...

Page 12

 Installing M-Series Systems
10432-0003-00-12 Rev 140 — M-Series Installation Guide 
When selecting a mounting location for the M-Series, consider cable lengths and 
cable routing. Ensure the cables are long enough, given the proposed mounting 
locations and cable routing requirements, and route the cables before you install 
the components. 
If you are using one of the top-down installation kits, the riser or plate should be 
used as a template for the location of the drill holes and cable access hole....

Page 13

432-0003-00-12 Rev 140 — M-Series Installation Guide 11
 Installing M-Series Systems
Physical Installation
Use a thread-locking compound such as Loctite 242 or equivalent with all metal-
to-metal threaded connections.
Installing the Camera Unit
With the exception of theM-618CS model, which must be installed in the ball-up 
orientation, the M-Series camera can be mounted in an upright or upside down 
position. Two O-rings are provided for use during the camera installation. You 
should choose the one most...

Page 14

 Installing M-Series Systems
12432-0003-00-12 Rev 140 — M-Series Installation Guide 
As an alternative to the mounting O-ring, you can use a marine-grade sealant 
such as 3M 5200 or the equivalent.
Mounting Upright
Caution: The cable connectors terminating the pigtail cables on the camera are 
not sealed connectors; therefore, appropriate sealing steps are needed to protect 
the connections and the camera.
Caution: Before drilling holes, ensure you have first followed the steps outlined 
in the planning...

Page 15

432-0003-00-12 Rev 140 — M-Series Installation Guide 13
 Installing M-Series Systems
Caution: An installation template is provided in the JCU ICD. If you print the 
template from the PDF file, ensure that it was printed to the correct scale by 
checking the dimensions prior to cutting any holes.
Standard JCU Mounting Instructions
1.Using the JCU template supplied as a guide in Doc. # 500-0385-19, mark the 
location of the rectangular opening that will allow the JCU to be recessed in the 
vessel’s control...

Page 16

 Installing M-Series Systems
14432-0003-00-12 Rev 140 — M-Series Installation Guide 
rear of the mounting surface and allows the clamp to contact thinner panel 
surfaces while still allowing for proper compression of the JCU mounting gasket 
to form a watertight seal.
Electrical Connections
Watertight connectors/enclosures should be used on each of the electrical 
connections. Table 1.1 shows the connections for the cables attached to the 
camera.
*VIS/IR cable is only available on dual payload models....

Page 17

432-0003-00-12 Rev 140 — M-Series Installation Guide 15
 Installing M-Series Systems
Proper Grounding
Caution: Ensure the camera is properly grounded. Following best grounding 
practices, the camera chassis ground should use the lowest resistance path 
possible. 
The green wire in the camera cable can be used to provide chassis ground for 
cable lengths under 2 m (6 ft). For longer cabling, the camera must be connected 
to a vessel ground using a low-resistance grounding strap connected directly to 
one...

Page 18

 Installing M-Series Systems
16432-0003-00-12 Rev 140 — M-Series Installation Guide 
Warning: Use of insufficient wire gauge can result in fire. Suggested gauge 
depends on supply voltage shown. For lower supply voltages, lower gauge wire 
must be used.
Video Connections
The video cables from the camera are terminated with F-type male connectors. 
Video cables of various lengths with F-type female connectors at one end and 
BNC-connectors at the other end are available from FLIR. The video cable used...

Page 19

432-0003-00-12 Rev 140 M-Series Installation Guide 17
CHAPTER 2M-Series Reference 
Introduction
This chapter includes the following reference information:
• A summary of maintenance procedures
• A table of camera specifications
• Information about standards referenced during the installation procedure
• A glossary of acronyms 
• A table comparing features of various M-Series models
M-Series Maintenance
The M-Series components are designed for years of rugged, trouble-free use. 
When the system is not in...

Page 20

 M-Series Reference
18432-0003-00-12 Rev 140 — M-Series Installation Guide 
designed for the harsh outdoor environment and have a coating for durability and 
anti-reflection, but may require cleaning occasionally. FLIR Systems Inc. 
suggests that you clean the lens when image quality degradation is noticed or 
excessive contaminant build-up is seen on the lens. 
Rinse the camera housing and optics with low pressure fresh water to remove 
any salt deposits and to keep it clean. If the front window of the...
Start reading Flir ThermovisionMSeries Installation Guide

Related Manuals for Flir ThermovisionMSeries Installation Guide

All Flir manuals