    							Monitoring window layout
    21
    Procedure
    Click the View menu, and select "Grouping view" or "Detail list 
    view".
    Monitoring using Grouping viewMeanings of Grouping view icons
    In Grouping view, the patterns on the icons indicate the statuses of the 
    projectors. If the group icons are round in shape, it indicates that there is 
    another level below them. sp.23 
    						
    							Monitoring window layout
    22
    The icon patterns and their meanings are explained below.
    *1 When Temperature level display group view is set to On at Environment 
    setup in the Tool menu, an icon indicating the internal temperature of the 
    projector will be displayed on top of the projector icon. The default setting 
    is Off. As you can get an idea of how the temperature inside the projector is 
    increasing when Temperature level is displayed, you can make 
    improvements to the projector's operating environment before a high 
    internal temperature error or high-temperature warning occur. sp.27
    *2 Check the following items.
    - Check that the projector's power is turned on.
    - Check that the LAN cable is connected.
    - Check that Standby Mode is set to Communication On (or Network On) 
    or Network Monitoring is set to On in the projector's configuration menu.
    *3 Check that the projector has been correctly connected to the network.
    q
    The projector information that is generated when a problem is detected is 
    stored until EasyMP Monitor is closed. EasyMP Monitor displays will not 
    be updated automatically even if the projector status returns to normal. 
    Click "Refresh" in the main window to update the status.
    Group
    No warnings or problems
    All projectors in the group are normal.
    Warning or problem
    A projector in the group has a warning or problem status.
    Notification
    A projector requiring immediate attention has been detected 
    within the group.
    Monitoring disabled
    The projector is not being monitored. If you right-click the icon and 
    select Monitoring enabled, the projector will be added to the 
    projectors that are being monitored.
    Data being updated Projector
    No warnings or problems
    *1
    Warning or problem
    Notification
    Monitoring disabled
    Data being updated
    Network error (Monitor Password authentication error)
    No Monitor Password was entered when the projector was 
    registered, or an incorrect Monitor Password was entered. sp.12, 
    p.15, p.16
    Network error (TCP connection error)
    *2
    Network error (ESC/VP.net communication error)
    *3
    Projector 
    						
    							Monitoring window layout
    23
    Using the icons in Grouping view
    The following icon operations can be carried out in Grouping view.
    •Expanding and collapsing icons
    Each time you double-click a group icon, the icons for the projector 
    that have been registered in that group are displayed or hidden.
    •Moving icons
    To change the position of an icon within Grouping view, simply drag 
    and drop the icon to be moved.
    Monitoring using Detail list viewMeanings of Detail list view icons
    The status of registered projectors is displayed as a list in Detail list view 
    regardless of which Group the projectors belong to. 
    						
    							Monitoring window layout
    24
    The icon patterns and their meanings are explained below.
    A
    Type
    Displays the projector status.
    No warnings or problems
    *1
    Warning or problem
    An error has occurred on the projector.
    Notification
    The projector requires immediate attention.
    Monitoring disabled
    The projector is not being monitored. If you right-click the icon 
    and select Monitoring enabled, the projector will be added to 
    the projectors that are being monitored.
    Data being updated 
    Network error (Monitor Password authentication error)
    No Monitor Password was entered when the projector was 
    registered, or an incorrect Monitor Password was entered. 
    sp.12, p.15, p.16
    Network error (TCP connection error)
    *2
    Network error (ESC/VP.net communication error)
    *3
    B
    Group name
    When projectors are registered to a group, the name of the group that 
    the projector belongs to is displayed.
    C
    Display name
    Shows the display name.
    D
    Power
    Shows the power on status for the projector.
    Power on and normal status Power off and normal status
    Power on and abnormal 
    statusPower off and abnormal 
    status
    E
    Lamp Hours
    Shows the lamp operating time for the projector. If the projector has 2 
    lamps, it shows the lamp operating time for both lamp 1 and lamp 2.
    F
    Temperature level
    The following five icons display the differing internal temperature 
    status of the projector.
    Internal temperature 
    normalInternal temperature 
    normal
    High-temperature 
    warningHigh-temperature 
    warning
    Internal temperature 
    error
    G
    Error information
    Shows a notification or warning/problem status using the following 
    icons.
    Clean Air Filter Notice Replace Lamp
    *4
    Replace Lamp (Lamp 1) Replace Lamp (Lamp 2)
    Lamp error (Lamp 1) Lamp error (Lamp 2)
    Lamp failure at power on 
    (Lamp 1)Lamp failure at power on 
    (Lamp 2)
    High-temperature warning Replace Air Filter
    No Air Filter Low Air Flow
    Air Flow Sensor Err. Supply System Error (Ballast 
    1)
    Supply System Error (Ballast 
    2)Cinema filter warning
    Shutter warning Lamp Cover Open
    Lamp Error Lamp Error (Lamp 1)
    Lamp Error (Lamp 2) Lamp failure at power on 
    						
    							Monitoring window layout
    25
    *1 When Temperature level display group view is set to On at Environment 
    setup in the Tool menu, an icon indicating the internal temperature of the 
    projector will be displayed on top of the projector icon. The default setting 
    is Off.
    *2 Check the following items.
    - Check that the projector's power is turned on.
    - Check that the LAN cable is connected.
    - Check that Standby Mode is set to Communication On (or Network On) 
    or Network Monitoring is set to On in the projector's configuration menu.
    *3 Check that the projector has been correctly connected to the network.
    *4 You can display Replace Lamp at any time by setting a preset in the 
    Environment setup in the Tool menu.
    q
    •The projector information that is generated when a problem is detected is 
    stored until EasyMP Monitor is closed. EasyMP Monitor displays will not 
    be updated automatically even if the projector status returns to normal. 
    Click "Refresh" in the main window to update the status.
    •Detectable error information differs with the projector you are using.
    Selecting display items
    You can select only the required items to be displayed in Detail list view.
    ProcedureA
    Select "Option" from the View menu.
    The Option window will be displayed.
    B
    Select the check box of the item you want to display.
    Lamp failure at power on 
    (Lamp 1)Lamp failure at power on 
    (Lamp 2)
    High internal temperature 
    errorLow air flow error
    Air filter air flow sensor error Internal Error
    Fan error Sensor error
    Supply System Error 
    (Ballast)Supply System Error (Ballast 
    1)
    Supply System Error (Ballast 
    2)Auto Iris Error
    Cinema filter error Shutter error
    Cooling system error 
    (Peltier element)Cooling system error 
    (pump)
    Other error Obstacle Detection 
    Warning
    Exhaust vent shutter error Easy Interactive Function 
    Error
    Obstacle Detection Error  
    						
    							Monitoring window layout
    26
    C
    Click "OK".
    D
    When all of the details of the item cannot be displayed in 
    Detail list view, drag the boundary line on the right of the 
    item name so that the view is extended to the desired width.
    Sorting lists
    You can sort detailed lists by using a specific row as a sort key, such as 
    projector name order or IP address order.
    Procedure
    Click the item name of the row you want to use as the sort key.
    Searching for desired icons (Projector list)
    The Projector list feature is useful for searching in lists when many 
    groups and projectors are registered and the icon you are looking for is 
    not displayed on screen.Procedure
    Select "Projector list" from the View menu.
    The following window will be displayed.
    With Projector list, temperature level icons are not displayed regardless 
    of the setting of Temperature level display group view at Environment 
    setup in the Tool menu.
    The Projector list lets you check the registration details for groups in a 
    hierarchical diagram. When you click on an icon, Grouping view and 
    Detail list view are scrolled so that the selected icon is displayed in the 
    window.
    Monitoring using the system tray
    The projector statuses are always displayed as icons in the system tray, 
    even when Grouping view or Detail list view is not always displayed, and 
    the statuses can be checked by the icon patterns. 
    						
    							Monitoring window layout
    27
    When the configuration menus are set using the following operations, an 
    icon appears in the system tray and the status can be monitored by means 
    of the icon's pattern.
    The icon patterns are explained below.
    ProcedureA
    Select "Environment setup" from the Tool menu.
    The Environment setup window will be displayed.
    B
    Select "Resident in the task tray".
    C
    Click "OK".
    q
    •Right-click the icon in the system tray to open a pop-up menu to select the 
    Open the main screen or Exit.
    •If Register at startup in the Environment setup is selected, EasyMP 
    Monitor starts automatically when the computer's power is turned on. 
    When using EasyMP Monitor under Windows Vista or Windows 7, you 
    must have administrator authority in order to use this function.
    Displaying projectors with problem or warning 
    statuses in a list
    You can display a list of only the projectors which have a problem or 
    warning status.
    Procedure
    Select "Warning and Error Projector list" from the View menu.
    The following Warning and Error Projector list window will be 
    displayed.
    No problem Problem 
    						
    							Monitoring window layout
    28
    If you move the mouse pointer over the icon of the Error information, 
    details of the error and the remedy will be displayed. If you double-click 
    in a line, the properties for that projector will be displayed. sp.31 
    						
    							Monitoring window layout
    29
    The icon patterns and their meanings are explained below.
    A
    Type
    Shows the group or projector status.
    No warnings or problems
    *1
    Warning or problem
    An error has occurred on the projector.
    Notification
    The projector requires immediate attention.
    Monitoring disabled
    The projector is not being monitored. If you right-click the icon 
    and select Monitoring enabled, the projector will be added to 
    the projectors that are being monitored.
    Data being updated 
    Network error (Monitor Password authentication error)
    No Monitor Password was entered when the projector was 
    registered, or an incorrect Monitor Password was entered. 
    sp.12, p.15, p.16 
    Network error (TCP connection error)
    *2
    Network error (ESC/VP.net communication error)
    *3
    B
    Display name
    Shows the display name.
    C
    Power
    Shows the power on status for the projector.
    Power on and normal status Power off and normal status
    Power on and abnormal 
    statusPower off and abnormal 
    status
    D
    Lamp Hours
    Shows the lamp operating time for the projector.
    E
    Source
    Shows the input source that has been selected for the projector.
    Computer or 
    Computer1Computer2
    BNC S-Video
    Video (RCA) Video (BNC)
    SDI DisplayPort
    DVI-D1 or HDMI1, 
    DVI-D, HDMI
    *4
    DVI-D2 or HDMI2
    *5
    D-Video EasyMP
    USB Display USB or USB1
    USB2 LAN
    F
    Temperature level
    The following five icons display the differing internal temperature 
    status of the projector.
    Internal temperature 
    normalInternal temperature 
    normal
    High-temperature 
    warningHigh-temperature 
    warning
    Internal temperature 
    error
    G
    Error information
    Shows a warning/problem status using the following icons.
    Replace Lamp
    *6
    Replace Lamp (Lamp 1) 
    						
    							Monitoring window layout
    30
    *1 When Temperature level display group view is set to On at Environment 
    setup in the Tool menu, an icon indicating the internal temperature of the 
    projector will be displayed on top of the projector icon. The default setting 
    is Off.
    *2 Check the following items.
    - Check that the projector's power is turned on.
    - Check that the LAN cable is connected.
    - Check that Standby Mode is set to Communication On (or Network On) 
    or Network Monitoring is set to On in the projector's configuration menu.
    *3 Check that the projector has been correctly connected to the network.
    *4 It describes DVI-D if the projector is equipped with both DVI-D and HDMI 
    input terminal.
    *5 It describes HDMI if the projector is equipped with both DVI-D and HDMI 
    input terminal.
    *6 You can display Replace Lamp at any time by setting a preset in the 
    Environment setup in the Tool menu.
    q
    Detectable error information differs with the projector you are using.
    Checking properties in detail
    You can check the properties of Group and projectors in detail.
    Displaying Group properties
    Procedure
    You can use either of the following methods to display the proper-
    ties.
    •Displaying the properties for all groups in Grouping view
    Right-click in Grouping view and select Property.
    Replace Lamp (Lamp 2) Lamp error (Lamp 1)
    Lamp error (Lamp 2) Lamp failure at power on 
    (Lamp 1)
    Lamp failure at power on 
    (Lamp 2)High-temperature warning
    Replace Air Filter No Air Filter
    Low Air Flow Air Flow Sensor Err.
    Supply System Error (Ballast 
    1)Supply System Error (Ballast 
    2)
    Cinema filter warning Shutter warning
    Lamp Cover Open Lamp Error
    Lamp Error (Lamp 1) Lamp Error (Lamp 2)
    Lamp failure at power on Lamp failure at power on 
    (Lamp 1)
    Lamp failure at power on 
    (Lamp 2)High internal temperature 
    error
    Low air flow error Air filter air flow sensor error
    Internal Error Fan error
    Sensor error Supply System Error 
    (Ballast)
    Supply System Error (Ballast 
    1)Supply System Error (Ballast 
    2)
    Auto Iris Error Cinema filter error
    Shutter error Cooling system error 
    (Peltier element)
    Cooling system error 
    (pump)Other error
    Exhaust vent shutter error Obstacle Detection warning 
    Easy Interactive Function 
    ErrorObstacle Detection Error 
    						
    All Epson manuals Comments (0)