61 Filter Instructions Filter prevents dust from accumulating on the optical elements inside the projector\ . Should the filter becomes clogged with dust particles, it will reduce cooling fans’ effectiveness and may result in internal heat buildup and adversely affect the life of the projector. This projector has an electrically operated filter which helps you to replace the filter easily. The projector monitors the condition of the filter at all time and replac\ es a filter with a new one automatically when it detects the clogging. If the projector reaches a time set in the timer setting (p. 60), a Filter replacement icon (Fig.1) appears on the screen and the WARNING FILTER indicator on the top panel lights up (p.77). When you see this icon, replace the filter as soon as possible (pp.33, 55). If the filter is out of scroll and the projector reaches a time set in the timer setting, Fig. 2 appears on the screen, indicating that the filter cartridge replacement is necessary. When the filter scroll is counted down to 1, the Last scroll icon (Fig.3) appears on the screen, indicating that there is one scroll left in the filter cartridge (p.60). If the projector detects that the filter is clogged and no scroll is left in the filter cartridge, a Filter cartridge replacement icon (Fig. 4) appears on the screen and the WARNING FILTER indicator on the top panel lights up (p.77). When you see this icon, replace the filter cartridge (p.62) and reset the Filter counter (p.63) and the Scroll counter (p.63). When the filter is being scrolled using the remote control (p.33) or the Filter control function in the setting menu (p.55), a Filter replacement icon and “Please wait...” message (Fig.5) appear on the screen and the WARNING FILTER indicator blinks slow (approx. 2 seconds ON, 2 seconds OFF) (p.75). The WARNING FILTER indicator blinks fast when the projector detects an abnormal condition, the filter cartridge is not installed properly, or the filter scroll is not working properly (p.77). Fig .1 Filter replacement icon Fig .4 Filter cartridge replacement icon Fig .3 Last scroll icon Maintenance and Care ✔Note: • Fig.1, Fig.2, Fig.3, Fig. 4 and Fig.5 will not appear when the Display function is set to “Off” (p.52) or during “Freeze” (p.33). • The filter cannot be rewound. • The filter can be scrolled 9 times since the filter cartridge has 10 scrolls. • The filter cartridge is disposable. Do not clean and reuse the filter cartridge. • Do not expose the filter cartridge to water or liquid, or it may cause a breakdown. • Replace the filter cartridge after all the scroll is used up. If you replace the filter cartridge when there are some scrolls left in the filter cartridge, the filter counter and the scroll counter do not recognize the correct number of remaining scrolls and the reset function cannot work properly. It may cause a breakdown. Fig .5 Filter replacement icon and “Please wait...” message. • Do not use the filter cartridge with other projector. The filter counter and the scroll counter do not recognize the correct number of remaining scrolls of the used filter cartridge and the reset function cannot work properly. It may cause a breakdown. • Make sure that the projection lamp is turn off when you are replacing the filter cartridge. If you replace the filter cartridge when the projection lamp is turn on, the projector will be shut down automatically for safety purpose • When you forget to reset the filter counter, the projector cannot recognize the correct number of remaining scrolls and may cause a breakdown. • Do not forget to reset the filter counter and the scroll counter in the setting menu after replacing the filter cartridge. If you forget to reset the filter counter and the scroll counter, the projector cannot recognize the correct number of remaining scrolls and may cause a breakdown. Fig .2
62 Turn off the projector, and unplug the AC power cord from the AC outlet. First, clean up the dust on the projector and around the air vents. 1 2 Press s on the filter cover to release the latch and open the filter cover.3 Put the new one back into the position and close the filter cover. Make sure that the filter cartridge is properly and fully inserted.5 CAUTION Make sure the filter cartridge is inserted in the projector. If the filter cartridge is not inserted, the projector cannot be turned on. Do not put anything into the air vents. Doing so may result in malfunction of the projector. 4 Reset the filter counter and the scroll counter (p.63). 6 Replacing the Filter Cartridge Pull out the filter cartridge. When taking out the filter cartridge, put your finger on the filter cartridge’s tab and then pull. RECOMMENDATION We recommend avoiding dusty/smoky environments when operating the projector . Usage in these environments may cause a poor image quality . When using the projector under dusty or smoky conditions, dust may accumulate on a lens, liquid crystal panels, or optical elements inside the projector. Such condition may degrade the quality of the projected image. When the symptoms above are noticed, contact your authorized dealer or service station for proper cleaning. ORDER REPLACEMENT FILTER CARTRIDGE Replacement filter cartridge can be ordered through your dealer. When ordering, give the following information to the dealer. ● Model No . of your projector LC-X85 ● Replacement Filter Cartridge Type No . Service Parts No . 610 334 3747 Connect the AC power cord to the projector and turn on the projector. 7 Maintenance and Care Filter cover Latch Filter cartridgeTab
63 Be sure to reset the Scroll counter after replacing the filter cartridge. Press the MENU button to display the On-Screen Menu. Use the Point 7 8 buttons to move the red frame pointer to the Setting Menu icon. Use the Point ed buttons to move the red frame pointer to Filter counter and then press the SELECT button. A dialog box appears showing the Used time option and the Scrolls remaining option. Use the Point ed buttons to select Scroll(s) remaining. 1 2 Resetting the Scroll CounterScroll counter Another confirmation dialog box appears, select [Yes] to reset the Scroll counter. 3Scroll(s) remaining shows the number of the remaining scrolls and the Reset option. Select Reset and the “Scroll counter Reset?” appears. Select [Yes] to continue. 4 Be sure to reset the Filter counter after replacing the filter cartridge. Press the MENU button to display the On-Screen Menu. Use the Point 7 8 buttons to move the red frame pointer to the Setting Menu icon. Use the Point ed buttons to move the red frame pointer to Filter counter and then press the SELECT button. A dialog box appears showing the Used time option and the Scrolls remaining option. Use the Point ed buttons to select Used time. 1 2 Resetting the Filter CounterFilter counter Select Reset and the “Filter counter Reset?” appears. Select [Yes], then another confirmation box appears. Select [Yes] again to reset the Filter counter. Another confirmation dialog box appears, select [Yes] to reset the Filter counter. 3Used time shows the total accumulated time of the filter use, a timer setting option, and the Reset option. Select Reset and the “Filter counter Reset?” appears. Select [Yes] to continue. 4 Select “Used time” and the dialogue box below appears. Select “Scrolls remaining” and the dialogue box below appears.Select Reset and the “Scroll counter Reset?” appears. Select [Yes], then another confirmation box appears. Select [Yes] again to reset the Scroll counter. Maintenance and Care
64 Turn off the projector and unplug the AC power cord. Let the projector cool for at least 45 minutes. Loosen the screw and open the lamp cover. Pull out the lamp by using the built in handle. 1 3 Replace the lamp with a new one. Make sure that the lamp is properly and fully inserted. 4 Open the filter cover. (p.62)2 Connect the AC power cord to the projector and turn on the projector. 6 Follow these steps to replace the lamp. Reset the Lamp counter (p.65) 5 ✔Note: • Be sure to insert the lamp in the correct direction. • Do not reset the Lamp counter when the projection lamp is not replaced. Lamp Replacement For continued safety, replace with a lamp of the same type. Do not drop the lamp or touch the glass bulb! The glass can shatter and may cause injury.Allow a projector to cool for at least 45 minutes before you open the lamp cover. The inside of the projector can become very hot. CAUTIONCAUTION When the projection lamp of the projector reaches its end of life, the Lamp replacement icon appears on the screen and LAMP REPLACE indicator lights orange. Replace the lamp with a new one promptly. The timing when the LAMP REPLACE indicator should light is depending on the lamp mode. Top Panel LAMP REPLACE indicator Lamp replacement icon ✔Note: • The Lamp replacement icon will not appear when the Display function is set to “Off” (p.52) or during “Freeze” (p.33) 7 Close the lamp cover and secure the screw. Maintenance and Care 8 Close the filter cover. Lamp Handle Lamp cover Filter cover Screw
65 ORDER REPLACEMENT LAMP Replacement lamp can be ordered through your dealer. When ordering, give the following information to the dealer. ● Model No . of your projector : LC-X85 ● Replacement Lamp Type No . : POA-LMP124 (Service Parts No. 610 341 1941) Resetting the Lamp Counter Be sure to reset the Lamp counter after the lamp is replaced. When the Lamp counter is reset, the LAMP REPLACE indicator stops lighting and the Lamp replacement icon disappears. ✔Note: • Do not reset the Lamp counter without replacing the lamp. Be sure to reset the Lamp counter only after replacing the lamp. Press the MENU button to display the On-Screen Menu. Use the Point 7 8 buttons to move the red frame pointer to the Setting Menu icon Use the Point ed buttons to move the red frame pointer to Lamp counter and then press the SELECT button. A dialog box appears showing the total accumulated time of the lamp usage and the reset option. Select Reset and the “Lamp replacement counter Reset?” appears. Select [Yes] to continue. 1 2 Lamp counter Select Reset and the “Lamp replacement counter Reset?” appears. Select [Yes] again to reset the lamp counter. Select [Yes], then another confirmation box appears. Another confirmation dialog box appears and select [Yes] to reset the Lamp counter.3 Maintenance and Care
66 This projector uses a high-pressure lamp which must be handled carefully and properly. Improper handling may result in accidents, injury, or create a fire hazard. ● Lamp lifetime may differ from lamp to lamp and according to the environment of use. There is no guarantee of the same lifetime for each lamp. Some lamps may fail or terminate their lifetime in a shorter period of time than other similar lamps. ● If the projector indicates that the lamp should be replaced, i.e., if the LAMP REPLACE indicator lights up, replace the lamp with a new one IMMEDIATELY after the projector has cooled down. (Follow carefully the instructions in the Lamp Replacement section of this manual.) Continuous use of the lamp with the LAMP REPLACE indicator lighted may increase the risk of lamp explosion. ● Lamp may explode as a result of vibration, shock or degradation as a result of hours of use as its lifetime draws to an end. Risk of explosion may differ according to the environment or conditions in which the projector and lamp are being used. IF A LAMP EXPLODES, THE FOLLOWING SAFET y PRECAUTIONS SHOULD BE TAKEN . If a lamp explodes, disconnect the projector’s AC plug from the AC outlet immediately. Contact an authorized service station for a checkup of the unit and replacement of the lamp. Additionally, check carefully to ensure that there are no broken shards or pieces of glass around the projector or coming out from the cooling air circulation holes. Any broken shards found should be cleaned up carefully. No one should check the inside of the projector except those who are authorized trained technicians and who are familiar with projector service. Inappropriate attempts to service the unit by anyone, especially those who are not appropriately trained to do so, may result in an accident or injury caused by pieces of broken glass. LAMP HANDLING PRECAUTIONS Maintenance and Care
67 Unplug the AC power cord before cleaning. Gently wipe the projection lens with a cleaning cloth that contains a small amount of non-abrasive camera lens cleaner, or use a lens cleaning paper or commercially available air blower to clean the lens. Avoid using an excessive amount of cleaner. Abrasive cleaners, solvents, or other harsh chemicals might scratch the surface of the lens. Cleaning the Projector Cabinet Unplug the AC power cord before cleaning. Gently wipe the projector body with a soft dry cleaning cloth. When the cabinet is heavily soiled, use a small amount of mild detergent and finish with a soft dry cleaning cloth. Avoid using an excessive amount of cleaner. Abrasive cleaners, solvents, or other harsh chemicals might scratch the surface of the cabinet. When the projector is not in use, put the projector in an appropriate carrying case to protect it from dust and scratches. Cleaning the Projection Lens Maintenance and Care
68 The WARNING indicators show the state of the function which protects the projector. Check the state of the WARNING indicators and the POWER indicator to take proper maintenance. Warning Indicators The projector is shut down and the WARNING TEMP. indicator is blinking red. When the temperature inside the projector reaches a certain level, the projector will be automatically shut down to protect the inside of the projector. The LAMP/SHUTTER indicator turns red and the WARNING TEMP indicator blinks while the projector is being cooled down. When the projector has cooled down enough (to its normal operating temperature), it can be turned on again by pressing the ON/ STAND-BY button. ✔Note: • The WARNING TEMP. indicator continues to blink even after the temperature inside the projector returns to normal. When the projector is turned on again, the WARNING TEMP. indicator stops blinking. Then check the matters below: – Did you provide appropriate space for the projector to be ventilated? Check the installing condition to see if the air vents of the projector are not blocked. – Has the projector been installed near an Air-Conditioning/ Heating Duct or Vent? Move the installation of the projector away from the duct or vent. – Is the filter clean? Replace the filter with a new one. The projector is shut down; and the LAMP/SHUTTER indicator is lighting red and other four indicators are blinking. When the projector detects an abnormal condition, it will be automatically shut down to protect the inside of the projector and the LAMP/SHUTTER indicator lights red and other four indicators blink. In this case, unplug the AC power cord and plug it, and then turn on the projector once again to verify operation. If the projector cannot be turned on and these indicators are still lighting and blinking, unplug the AC power cord and contact the service station. CAUTION DO NOT LEAVE THE PROJECTOR WITH THE AC POWER CORD CONNECTED UNDER AN ABNORMAL CONDITION. IT MAY RESULT IN FIRE OR ELECTRIC SHOCK. Top Panel LAMP/SHUTTER indicator lights red and other four indicators blink Top Panel WARNING TEMP . blinking red Maintenance and Care
69 Troubleshooting Before calling your dealer or service center for assistance, check the items below once again. 1. Make sure you have properly connected the projector to peripheral equipment as described \ on pages 22–24. 2. Check the cable connection. Make sure that all computers, video equipment, and power cords are properly connected. 3. Make sure that all power is switched on. 4. If the projector still does not produce an image, restart your computer. 5. If an image still does not appear, disconnect the projector from your computer and check your computer monitor’s display. A problem may be noticed with your graphics controller rather than with the projector. (When you reconnect the projector, be sure to turn the computer and monitor off before you turn on the projector. Turn on equipment in the order of the projector and computer.) 6. If a problem still persists, check the following solutions. Appendix Problem: Solutions No power. – Plug the power cord of the projector into the AC outlet. – Wait until the POWER indicator stops blinking to turn on the projector again. (See page 26) – Check the WARNING TEMP. indicator. If the WARNING TEMP. indicator is blinking, the projector cannot be turned on. (See page 68.) – Unlock the Key lock function for the projector. (See page 57) – See if the filter cartridge is inserted. (See page 62) – Check the projection lamp. (See page 64.) PIN code dialog box appears at start-up.– PIN code lock is being set. Enter a PIN code; the “1234” or numbers you have set (See pages 26, 57-58) The initial display is not shown.– Make sure “Off ” or “Countdown Off” are not chosen at Display function. (See “SETTING” section on page 52) The initial display is not same with the default one.– Make sure “User” or “Off” are not chosen at Logo select function. (See “SETTING” section on page 53) When the projector is on and you press the input button, an icon other than the Lamp mode icon appears. – That is the Filter warning icon. (See page 61.) An icon other than Input mode or Lamp mode icon appears. – That is the Lamp replacement icon or the Filter warning icon. (See pages 60-61.) No image. – Check the connection between your computer or video equipment and the projector. – See if the input signal is correctly output from your computer. Some laptop computers may need to be changed the setting for monitor output when connected to the projector. See your computer’s instruction manual for the setting. – It takes about 30 seconds to display an image after turning on the projector. – See if the selected system is corresponding with your computer or video equipment. – Select correct input source once again through menu operation (See pages 35-37)\ . – Make sure the temperature is not out of Operating Temperature (41˚F–104˚F [5˚C– 40˚C]). appears on the screen – End of lamp life is approaching. Replace the lamp with a new one promptly. (See pages 59, 64-65)
70 appears on the screen – Filter is out of scroll. Replace the filter cartridge with a new one promptly. (See pages 62 -63) The image is out of focus. – Adjust the focus of the projector. – Check Projection Lens to see if it needs cleaning. ✔Note: Moving the projector from a cool temperature location to a warm temperature location may result in moisture condensation on Projection Lens. In such cases, leave the projector OFF and wait until condensation evaporates. – Projecting from excessive slant angle to the screen may cause keystone distortion and partial imperfect focus. – Make sure the projection screen is at least 4.6’ (1.4 m) away from the projector. The image is not bright enough. – Check if “Contrast” or “Brightness” are adjusted properly. (See page 49) – Check if “Image level” is selected properly. (See pages 42, 46) – Check the Lamp control function. ( See “SETTING” section on page 55) – Check the LAMP REPLACE indicator. If it lights, the end of lamp life is approaching. Replace the lamp with a new one promptly. (See page 64) The color is strange.– Check the Input signal, color system, video system, or computer system mode. – Adjust the Image Level properly. (See pages 42, 46) The image is Left/Right reversed.– Check the Ceiling / Rear function. (See pages 44, 48.) The image is Top/Bottom reversed.– Check the Ceiling function. (See pages 44, 48.) The image is distorted or runs off.– Check “PC Adjust” menu or “ Screen” menu and adjust them. Auto PC adjustment function does not work.– Check the Input signal. Auto PC Adjustment function cannot work when 480p, 575p, 720p, 480i, 575i, 1035i, or 1080i is selected or when the digital signal is input into DVI terminal. (See page 39) Some displays are not seen during the operation.– Check the Display function (see page 52). The setting does not remain after turning off power.– Make sure you selected “Store” after adjusting settings. Some settings cannot be stored if not registered with “Store”. Power management function does not work.– Power management function cannot work while “Freeze” function is running or the shutter is closed. Image disappears automatically.– Check the power management function in the Setting. The power management is set to "On" at the factory. Capture function does not work.– Check the connection to see if there is signal. Some menus cannot be selected.– Each of the Video Input and Computer Input has a limit on selectable menus. No sound – Check the audio cable connection from audio input source. – Adjust the audio source. – Press the Volume + button. ( See page 31) – Press the Mute button. (See page 31) – Is the image projected? You will hear the sound only when the image is projected. – Make sure you selected correct Input pattern. (See page 31) Appendix