– 37 – LAN_RJ45 1. Connect an RJ45 cable to RJ45 ports on the projector and the PC (Laptop). 2. On the PC (Laptop), select Start → Control Panel →Network and Internet.
— 38 — 3. Right-click on Local Area Connection, and select Properties. 4. In the Properties window, select the Networking tab, and select Internet Protocol (TCP/IP). 5. Click Properties. 6. Click Use the following IP address and fill in the IP address and Subnet mask, then click OK.
– 39 – 7. Press the Menu button on the projector. 8. Select Settings2→ Advanced1 → Network 9. After getting into Network, input the following: DHCP: Off IP Address: 10.10.10.10 Subnet Mask: 255.255.255.0 Gateway: 0.0.0.0 DNS Server: 0.0.0.0 10. Press (Enter) / ► to confirm settings. Open a web browser (for example, Microsoft Internet Explorer with Adobe Flash Player 9.0 or higher). 11. In the Address bar, input the IP address: 10.10.10.10. 12. Press (Enter) / ►. The projector is setup for remote management. The LAN/RJ45 function displays as follows.
— 40 — CATEGORY ITEM INPUT-LENGTH Crestron Control IP Address 15 IP ID 3 Port 5 Projector Projector Name 10 Location 10 Assigned To 10 Network Configuration DHCP (Enabled) (N/A) IP Address 15 Subnet Mask 15 Default Gateway 15 DNS Server 15 User Password Enabled (N/A) New Password 10 Confirm 10 Admin Password Enabled (N/A) New Password 10 Confirm 10 For more information, please visit http://www.crestron.com.
– 41 – Preparing Email Alerts 1. Make sure that user can access the homepage of LAN RJ45 function by web browser (for ex- ample, Microsoft Internet Explorer v6.01/v8.0). 2. From the Homepage of LAN/RJ45, click Alert Settings. 3. By default, these input boxes in Alert Settings are blank.
— 42 — 4. For Sending alert mail, input the following: The SMTP field is the mail server for sending out email (SMTP protocol). This is a required field. The To field is the recipient’s email address (for example, the projector administrator). This is a required field. The Cc field sends a carbon copy of the alert to the specified email address. This is an optional field (for example, the projector administrator’s assistant). The From field is the sender’s email address (for example, the projector administrator). This is a required field. Select the alert conditions by checking the desired boxes. Note: Fill in all fields as specified. User can click Send Test Mail to test what setting is correct. For successful sending an e-mail alert, you must select alert conditions and enter a correct e-mail address.
– 43 – RS232 by Telnet Function Besides projector connected to RS232 interface with “Hyper-Terminal” communication by dedicated RS232 command control, there is alternative RS232 command control way, so called “RS232 by TELNET” for LAN/RJ45 interface. Quick Start-Guide for “RS232 by TELNET” Check and get the IP-Address on OSD of the projector. Make sure that laptop/PC can access the web-page of the projector. Make sure that “Windows Firewall” setting to be disabled in case of “TELNET” function filtering out by laptop/PC. Start => All Programs => Accessories => Command Prompt
— 44 — Input the command format like the below: telnet ttt.xxx.yyy.zzz 23 (“Enter” key pressed) (ttt.xxx.yyy.zzz: IP-Address of the projector) If Telnet-Connection ready, and user can have RS232 command input, then “Enter” key pressed, the RS232 command will be workable. How to have TELNET enabled in Windows VISTA / 7 By default installation for Windows VISTA, “TELNET” function is not included. But end-user can have it by way of “Turn Windows features On or Off” to be enabled. Open “Control Panel” in Windows VISTA Open “Programs”
– 45 – Select “Turn Windows features on or off” to open Have “Telnet Client” option checked, then press “OK” button. Specsheet for “RS232 by TELNET” : 1. Telnet: TCP 2. Telnet port: 23 (for more detail, kindly please get contact with the service agent or team) 3. Telnet utility: Windows “TELNET.exe” (console mode) 4. Disconnection for RS232-by-Telnet control normally: Close Windows Telnet utility directly after TELNET connection ready 5. Limitation 1 for Telnet-Control: there is less than 50 bytes for successive network payload for Telnet-Control application. Limitation 2 for Telnet-Control: there is less than 26 bytes for one complete RS232 command for Telnet-Control. Limitation 3 for Telnet-Control: Minimum delay for next RS232 command must be more than 200 (ms). (*, In Windows built-in “TELNET.exe” utility, “Enter” key pressed will have “Carriage-Return” and “New-Line” code.)
— 46 — Advanced 2 Feature Press the Menu button to open the OSD menu. Press ◄► to move to the Settings 2 menu. Press ▲▼ to move to the Advanced 2 menu and then press Enter or ►. Press ▲▼ to move up and down in the Advanced 2 menu. Press ◄► to enter and change values for setting. ITEM DESCRIPTION Sleep Timer Press the cursor ◄► button to enter and set Sleep timer. The projector automatically turns off after the preset period of time. Source Filter Press (Enter) / ► to enter the Source Filter menu. See page 47 for more information on Source Filter. Wall Color Press the cursor ◄► button to enable or disable the wall color functionK