    							11
    When the projector connects network, the projector can be controlled with RS-
    232C commands from the computer with web browser. 
    For details of RS-232C commands, refer to RS-232C Communication / Network 
    command table 
    (&17).
    Command Control via the Network
    Connection
    1. Turn off the projector and the computer.
    2. If you use wired LAN, connect the projector's 
    LAN port to the computer's 
    LAN port with a LAN cable. Use the cable that fulfi lls the specifi cation shown 
    in fi gure. If you use wireless LAN, insert the USB wireless adapter into the 
    projector's USB TYPE A port.
    3. Turn the computer on, and after the computer has started up turn the 
    projector on.
    NOTE • If data is transferred via wireless and wired LAN at the same time, 
    the projector may not be able to process the data correctly.
    Command Control via the Network
    LAN cable (CAT-5 or greater)
    LAN
    LAN 
    						
    							12
    Communication Port
    The following two ports are assigned for the command control.TCP #23
    TCP #9715
    Configure the following items form a web browser when command control is used.
    Port Settings
    Network Control 
    Port1 (Port: 23) Port open
    Click the [Enable] check box to open [Network 
    Control Port1 (Port: 23)] to use TCP #23.
    Default setting is “Enable”.
    Authentication Click the [Enable] check box for the 
    [Authentication] setting when authentication 
    is required.
    Default setting is “Disable”.
    Network Control 
    Port2 (Port: 9715) Port open
    Click the [Enable] check box to open [Network 
    Control Port2 (Port: 9715)] to use TCP 
    #9715.
    Default setting is “Enable”.
    Authentication Click the [Enable] check box for the 
    [Authentication] setting when authentication 
    is required.
    Default setting is “Enable”.
    Command Control via the Network (continued)
    When the authentication setting is enabled, the following settings are required.
    Security Settings
    Network Control Authentication 
    Password
    Enter the desired authentication password. 
    ConfirmThis setting will be the same for 
    [Network Control Port1 (Port: 23)] and 
    [Network Control Port2 (Port: 9715)].
    Default setting is blank.
    Re-enter 
    Authentication 
    Password 
    						
    							13
    Command Control via the Network (continued)
    Command control settings
    [TCP #23]
    1. Command format
    Same as RS-232C communication, refer to RS-232C Communicaton command format.
    2. Response code / Error code ("h" shows hexadecimal)
    Four of the response / error code used for TCP#23 are the same as RS-232C 
    Communication (1)~(4). One authentication error reply (5) is added.
    (1)    ACK reply : 06h 
    Refer to RS-232C communication  (
    &10).
    (2)   NAK reply : 15h 
    Refer to RS-232C communication  (
    &10).
    (3)   Error reply : 1Ch + 0000h 
    Refer to RS-232C communication  (
    &10).
    (4)   Data reply : 1Dh + xxxxh 
    Refer to RS-232C communication  (
    &10).
    (5)    Authentication error reply : 1Fh + 0400h 
    When authentication error occurred, the projector returns the error code.
    [TCP #9715]
    1. Command format
    The  commands  some  datum  are  added  to  the  head  and  the  end  of  the  ones  of 
    TCP#9715 are used.
    Header Data length RS-232C command Check sumConnection ID
    0×02 0×0D 13 bytes1 byte 1 byte
    [Header] 
    02, Fixed
    [Data Length] 
    RS-232C commands byte length (0×0D, Fixed)
    [RS-232C commands]  
    Refer to RS-232C Communication command format  (
    &9)
    .
    [Check Sum] 
    This is the value to make zero on the addition of the lower 8 bits from the header 
    to the checksum.
    [Connection ID]  
    Random value from 0 to 255 (This value is attached to the reply data).
    NOTE  •  Operation  cannot  be  guaranteed  when  the  projector  receives  an 
    undefined command or data.
    • Provide an interval of at least 40ms between the response code and any other 
    code. • Commands are not accepted during warm-up. 
    						
    							14
    2. Response code / Error code ("h" shows hexadecimal)
    The  connection  ID  is  attached  for  the  TCP#23's  response  /  error  codes  are 
    used. The connection ID is same as the sending command format.
    (1) ACK reply : 06h + ××h                    (××h : connection ID)
    (2) NAK reoly : 15h + ××h
    (3) Error reply : 1Ch + 0000h + ××h
    (4) Data reply : 1Dh + xxxxh + ××h
    (5) Authentication error reply : 1Fh + 0400h + ××h
    (6)   Projector busy reply: 1Fh + ××××h + ××h 
    When the projector is too busy to receives the command ,the projector 
    returens the error code.  
    In such a case, check the sending code and send the same command again.
    Automatic Connection Break
    T h e   T C P  c o n n e c t i o n   w i l l   b e   a u t o m a t i c a l l y   d i s c o n n e c t e d   a f t e r   t h e r e   i s   n o 
    communication for 30 seconds after being established.
    Authentication
    The  projector  does  not  accept  commands  without  authentication  success 
    when  authentication  is  enabled.  The  projector  uses  a  challenge  response  type 
    authentication  with  an  MD5  (Message  Digest  5)  algorithm.  When  the  projector  is 
    using  a  LAN,  a  random  8  bytes  will  be  returned  if  authentication  is  enabled.  Bind 
    this  received  8  bytes  and  the  authentication  password  and  digest  this  data  with 
    the MD5 algorithm and add this in front of the commands to send.
    Following  is a sample  if the authentication  password  is set to “password”  and  the 
    random 8 bytes are “a572f60c”.
    1)  Select the projector.
    2)  Receive the random 8 bytes “a572f60c” from the projector.
    3)    B i n d   t h e   r a n d o m   8   b y t e s   “ a 5 7 2 f 6 0 c ”   a n d   t h e   a u t h e n t i c a t i o n   p a s s w o r d 
    “password” and it becomes “a572f60cpassword”.
    4)    Digest this bind “a572f60cpassword” with MD5 algorithm.
      It will be “e3d97429adffa11bce1f7275813d4bde”.
    5)    Add this “e3d97429adffa11bce1f7275813d4bde” in front of the commands and 
    send the data.
      Send “e3d97429adffa11bce1f7275813d4bde”+command.
    6)    When  the  sending  data  is  correct,  the  command  will  be  performed  and  the 
    reply data will be returned. Otherwise, an authentication error will be returned.
    NOTE  • As  for  the  transmission  of  the  second  or  subsequent  commands, 
    the authentication data can be omitted when the same connection.
    Command Control via the Network (continued) 
    						
    							15
    This projector is equipped with NETWORK BRIDGE function.
    When the projector connects to the computer by wired or wireles LAN 
    communicaton, an external device that is connected with this projector by RS-
    232C communication can be controlled from the computer as a network terminal.
    For details, see the 6. Network Bridge function in the Network Guide.
    Network Bridge Communication 
    NOTE • If data is transferred via wireless and wired LAN at the same time, 
    the projector may not be able to process the data correctly.
    Connection
    1. If you use wired LAN, connect the computer's LAN port and the projector's  LAN 
     port with a LAN cable. Use the cable that fulfi lls the specifi cation shown in fi gure. 
    If you use wireless LAN, insert the USB wireless adapter into the projector ’s 
    USB TYPE A port.
    2.  Connect the projector's  CONTROL port and the RS-232C port of the devices 
    that you want to control with a RS-232C cable.
    3. Turn the computer on, and after the computer has started up turn the 
    projector on.
    4. Set the COMMUNICATION TYPE to  NETWORK BRIDGE. (&OPTION menu 
    - SERVICE - COMMUNICATION  in the Operating Guide)
    Network Bridge Communication
    LAN
    CONTROL 
    LAN
    RS-232C
    LAN cable 
    (CAT-5 or greater) 
    						
    							16
    Communication settings 
    For communication setting, use the OPTION - SERVICE - COMMUNICATION 
    menu. (
    &OPTION menu - SERVICE - COMMUNICATION in the Operating 
    Guide )
    Item Condition
    BAUD RATE 4800bps / 9600bps / 19200bps / 38400bps Data length 8 bit (fixed) PARITY NONE/ODD/EVENStart bit 1 bit (fixed)Stop bit 1 bit (fixed)
    Transmission method HALF-DUPLEX /FULL-DUPLEX
    NOTE  • For  connecting  the  projector  to  your  devices,  please  read  the 
    manual for each devices, and connect them correctly with suitable cables. 
    •  Turn  off  (the  power  of  )  both  the  projector  and  other  devices  and  unplug  , 
    beore connecting them.
    • For details of Transmission method, refer to  6.4 Transmission method in the 
    Network Guide.
    Network Bridge Communication (continued) 
    						
    							17
    RS-232C Communication / Network command table
    (continued on next page)
    RS-232C Communication / Network command table
    Names  Operation Type Header Command Data
    CRC Action Type Setting Code
    Power Set
    Turn off BE  EF 03 06  00 2A  D3 01  00 00  60 00  00
    Turn on BE  EF 03 06  00 BA  D2 01  00 00  60 01  00
    Get BE  EF 03 06  00 19  D3 02  00 00  60 00  00
    [Example return]
      00  00  01  00 02  00 
      [Off]  [On] [Cool down]
    Input Source SetCOMPUTER IN1 BE  EF 03 06  00 FE  D2 01  00 00  20 00  00
    COMPUTER IN2 BE  EF 03 06  00 3E  D0 01  00 00  20 04  00 HDMI BE  EF 03 06  00 0E  D2 01  00 00  20 03  00
    S-VIDEO BE  EF 03 06  00 9E  D3 01  00 00  20 02  00 VIDEO BE  EF 03 06  00 6E  D3 01  00 00  20 01  00 LAN BE EF 03 06 00 CE D5 01 00 00 20 0B 00
    USB TYPE A BE EF 03 06 00 5E D1 01 00 00 20 06 00
    USB TYPE B BE EF 03 06 00 FE D7 01 00 00 20 0C 00 Get BE  EF 03 06  00 CD  D2 02  00 00  20 00  00
    Error Status GetBE  EF 03 06  00 D9  D8 02  00 20  60 00  00
    [Example return]
      00  00  01  00  02  00 03  00 
      [Normal]  [Cover error]  [Fan error] [Lamp error]
      04  00  05  00  07  00  08 00 
    	 [Temp	error]	 [Air	flow	error]	 [Cold	error]	 [Filter	error]
    MAGNIFY Get
    BE  EF 03 06  00 7C  D2 02  00 07  30 00  00
    Increment BE  EF 03 06  00 1A  D2 04  00 07  30 00  00
    Decrement BE  EF 03 06  00 CB  D3 05  00 07  30 00  00
    Magnify Position H Get
    BE  EF 03 06  00 C8  D7 02  00 10  30 00  00
    Increment BE  EF 03 06  00 AE  D7 04  00 10  30 00  00
    Decrement BE  EF 03 06  00 7F  D6 05  00 10  30 00  00
    Magnify Position V Get
    BE  EF 03 06  00 34  D6 02  00 11  30 00  00
    Increment BE  EF 03 06  00 52  D6 04  00 11  30 00  00
    Decrement BE  EF 03 06  00 83  D7 05  00 11  30 00  00
    FREEZE SetNORMAL BE  EF 03 06  00 83  D2 01  00 02  30 00  00
    FREEZE BE  EF 03 06  00 13  D3 01  00 02  30 01  00
    Get BE  EF 03 06  00 B0  D2 02  00 02  30 00  00
    PICTURE MODE SetNORMAL BE  EF 03 06  00 23  F6 01  00 BA  30 00  00
    CINEMA BE  EF 03 06  00 B3  F7 01  00 BA  30 01  00
    DYNAMIC BE  EF 03 06  00 E3  F4 01  00 BA  30 04  00
    BOARD(BLACK) BE  EF 03 06  00 E3  EF 01  00 BA  30 20  00
    BOARD(GREEN) BE  EF 03 06  00 73  EE 01  00 BA  30 21  00 WHITEBOARD BE  EF 03 06  00 83  EE 01  00 BA  30 22  00 DAYTIME BE  EF 03 06  00 E3  C7 01  00 BA  30 40  00PHOTO BE  EF 03 06  00 73 F5 01 00 BA 30 05 00
    Get BE  EF 03 06  00 10  F6 02  00 BA  30 00  00
    [Example return]
      00  00  01  00 04  00 10  00  
      [Normal]  [Cinema] [Dynamic]  [Custom]   
      20  00  21  00 22  00 40  00 
         [BOARD(BLACK)]  [BOARD(GREEN)] [WHITEBOARD]  [DAY TIME] 
    						
    							18
    RS-232C Communication / Network command table (continued)(continued on next page)
    Names Operation Type Header Command Data
    CRC Action Type Setting Code
    BRIGHTNESS Get
    BE  EF 03 06  00 89  D2 02  00 03  20 00  00
    Increment BE  EF 03 06  00 EF  D2 04  00 03  20 00  00
    Decrement BE  EF 03 06  00 3E  D3 05  00 03  20 00  00
    BRIGHTNESS Reset Execute BE  EF 03 06  00 58  D3 06  00 00  70 00  00
    CONTRAST Get
    BE  EF 03 06  00 FD  D3 02  00 04  20 00  00
    Increment BE  EF 03 06  00 9B  D3 04  00 04  20 00  00
    Decrement BE  EF 03 06  00 4A  D2 05  00 04  20 00  00
    CONTRAST Reset ExecuteBE  EF 03 06  00 A4  D2 06  00 01  70 00  00
    GAMMA SetDEFAULT-1
    BE  EF 03 06  00 07  E9 01  00 A1  30 20  00
    CUSTOM-1 BE  EF 03 06  00 07  FD 01  00 A1  30 10  00
    DEFAULT-2 BE  EF 03 06  00 97  E8 01  00 A1  30 21  00
    CUSTOM-2 BE  EF 03 06  00 97  FC 01  00 A1  30 11  00
    DEFAULT-3 BE  EF 03 06  00 67  E8 01  00 A1  30 22  00
    CUSTOM-3 BE  EF 03 06  00 67  FC 01  00 A1  30 12  00
    DEFAULT-4 BE  EF 03 06  00 F7  E9 01  00 A1  30 23  00
    CUSTOM-4 BE  EF 03 06  00 F7  FD 01  00 A1  30 13  00
    DEFAULT-5 BE  EF 03 06  00 C7  EB 01  00 A1  30 24  00
    CUSTOM-5 BE  EF 03 06  00 C7  FF 01  00 A1  30 14  00
    DEFAULT-6 BE  EF 03 06  00 57  EA 01  00 A1  30 25  00
    CUSTOM-6 BE  EF 03 06  00 57  FE 01  00 A1  30 15  00
    DEFAULT-7 BE  EF 03 06  00  A7 EA 01  00 A1  30 26  00
    CUSTOM-7 BE  EF 03 06  00  A7 FE 01  00 A1  30 16  00
    Get BE  EF 03 06  00 F4  F0 02  00 A1  30 00  00
    User Gamma Pattern SetOff
    BE  EF 03 06  00 FB  FA 01  00 80  30 00  00
    9 steps gray scale BE  EF 03 06  00 6B  FB 01  00 80  30 01  00
    15 steps gray scale BE  EF 03 06  00 9B  FB 01  00 80  30 02  00
    Ramp BE  EF 03 06  00 0B  FA 01  00 80  30 03  00
    Get BE  EF 03 06  00 C8  FA 02  00 80  30 00  00
    User Gamma Point 1 Get
    BE  EF 03 06  00 08  FE 02  00 90  30 00  00
    Increment BE  EF 03 06  00 6E  FE 04  00 90  30 00  00
    Decrement BE  EF 03 06  00 BF  FF 05  00 90  30 00  00
    User Gamma Point 1 ResetExecuteBE  EF 03 06  00 58  C2 06  00 50  70 00  00
    User Gamma Point 2 Get
    BE  EF 03 06  00 F4  FF 02  00 91  30 00  00
    Increment BE  EF 03 06  00 92  FF 04  00 91  30 00  00
    Decrement BE  EF 03 06  00 43  FE 05  00 91  30 00  00
    User Gamma Point 2 ResetExecuteBE  EF 03 06  00 A4  C3 06  00 51  70 00  00
    User Gamma Point 3 Get
    BE  EF 03 06  00 B0  FF 02  00 92  30 00  00
    Increment BE  EF 03 06  00 D6  FF 04  00 92  30 00  00
    Decrement BE  EF 03 06  00 07  FE 05  00 92  30 00  00
    User Gamma Point 3 ResetExecuteBE  EF 03 06  00 E0  C3 06  00 52  70 00  00
    User Gamma Point 4 Get
    BE  EF 03 06  00 4C  FE 02  00 93  30 00  00
    Increment BE  EF 03 06  00 2A  FE 04  00 93  30 00  00
    Decrement BE  EF 03 06  00 FB  FF 05  00 93  30 00  00
    User Gamma Point 4 ResetExecuteBE  EF 03 06  00 1C  C2 06  00 53  70 00  00
    User Gamma Point 5 Get
    BE  EF 03 06  00 38  FF 02  00 94  30 00  00
    Increment BE  EF 03 06  00 5E  FF 04  00 94  30 00  00
    Decrement BE  EF 03 06  00 8F  FE 05  00 94  30 00  00
    User Gamma Point 5 ResetExecuteBE  EF 03 06  00 68  C3 06  00 54  70 00  00 
    						
    							19
    RS-232C Communication / Network command table (continued)
    Names Operation Type Header Command Data
    CRC Action Type Setting Code
    User Gamma Point 6 Get
    BE  EF 03 06  00 C4  FE 02  00 95  30 00  00
    Increment BE  EF 03 06  00 A2  FE 04  00 95  30 00  00
    Decrement BE  EF 03 06  00 73  FF 05  00 95  30 00  00
    User Gamma Point 6 ResetExecuteBE  EF 03 06  00 94  C2 06  00 55  70 00  00
    User Gamma Point 7 Get
    BE  EF 03 06  00 80  FE 02  00 96  30 00  00
    Increment BE  EF 03 06  00 E6  FE 04  00 96  30 00  00
    Decrement BE  EF 03 06  00 37  FF 05  00 96  30 00  00
    User Gamma Point 7 ResetExecuteBE  EF 03 06  00 D0  C2 06  00 56  70 00  00
    User Gamma Point 8 Get
    BE  EF 03 06  00 7C  FF 02  00 97  30 00  00
    Increment BE  EF 03 06  00 1A  FF 04  00 97  30 00  00
    Decrement BE  EF 03 06  00 CB  FE 05  00 97  30 00  00
    User Gamma Point 8 ResetExecute BE  EF 03 06  00 2C  C3 06  00 57  70 00  00
    COLOR TEMP Set1 HIGH BE  EF 03 06  00 0B  F5 01  00 B0  30 03  00
    1 CUSTOM BE  EF 03 06  00 CB  F8 01  00 B0  30 13  00 2 MID BE  EF 03 06  00 9B  F4 01  00 B0  30 02  00
    2 CUSTOM BE  EF 03 06  00 5B  F9 01  00 B0  30 12  00 3 LOW BE  EF 03 06  00 6B  F4 01  00 B0  30 01  00
    3 CUSTOM BE  EF 03 06  00 AB  F9 01  00 B0  30 11  00
    4 Hi-BRIGHT-1 BE  EF 03 06  00 3B  F2 01  00 B0  30 08  00 4 CUSTOM BE  EF 03 06  00 FB  FF 01  00 B0  30 18  00
    5 Hi-BRIGHT-2 BE  EF 03 06  00 AB  F3 01  00 B0  30 09  00 5 CUSTOM BE  EF 03 06  00 6B  FE 01  00 B0  30 19  00
    6 Hi-BRIGHT-3 BE  EF 03 06  00 5B  F3 01  00 B0  30 0A  00 6 CUSTOM BE  EF 03 06  00 9B  FE 01  00 B0  30 1A  00
    7 Hi-BRIGHT-4 BE  EF 03 06  00 CB F2 01  00 B0  30 0B 00 7 CUSTOM BE  EF 03 06  00 0B FF 01  00 B0  30 1B 00Get BE  EF 03 06  00 C8  F5 02  00 B0  30 00  00
    COLOR TEMP GAIN R Get
    BE  EF 03 06  00 34  F4 02  00 B1  30 00  00
    Increment BE  EF 03 06  00 52  F4 04  00 B1  30 00  00
    Decrement BE  EF 03 06  00 83  F5 05  00 B1  30 00  00
    COLOR TEMP GAIN R  Reset Execute
    BE  EF 03 06  00 10  C6 06  00 46  70 00  00
    COLOR TEMP GAIN G Get
    BE  EF 03 06  00 70  F4 02  00 B2  30 00  00
    Increment BE  EF 03 06  00 16  F4 04  00 B2  30 00  00
    Decrement BE  EF 03 06  00 C7  F5 05  00 B2  30 00  00
    COLOR TEMP GAIN G  Reset Execute
    BE  EF 03 06  00 EC  C7 06  00 47  70 00  00
    COLOR TEMP GAIN B Get
    BE  EF 03 06  00 8C  F5 02  00 B3  30 00  00
    Increment BE  EF 03 06  00 EA  F5 04  00 B3  30 00  00
    Decrement BE  EF 03 06  00 3B  F4 05  00 B3  30 00  00
    COLOR TEMP GAIN B  Reset Execute
    BE  EF 03 06  00 F8  C4 06  00 48  70 00  00
    COLOR TEMP  OFFSET R Get
    BE  EF 03 06  00 04  F5 02  00 B5  30 00  00
    Increment BE  EF 03 06  00 62  F5 04  00 B5  30 00  00
    Decrement BE  EF 03 06  00 B3  F4 05  00 B5  30 00  00
    COLOR TEMP 
    OFFSET R  Reset Execute
    BE  EF 03 06  00 40  C5 06  00 4A  70 00  00
    (continued on next page) 
    						
    							20
    RS-232C Communication / Network command table (continued)
    Names Operation Type Header Command Data
    CRC Action Type Setting Code
    COLOR TEMP  OFFSET G Get
    BE  EF 03 06  00 40  F5 02  00 B6  30 00  00
    Increment BE  EF 03 06  00 26  F5 04  00 B6  30 00  00
    Decrement BE  EF 03 06  00 F7  F4 05  00 B6  30 00  00
    COLOR TEMP 
    OFFSET G Reset Execute
    BE  EF 03 06  00 BC  C4 06  00 4B  70 00  00
    COLOR TEMP  OFFSET B Get
    BE  EF 03 06  00 BC  F4 02  00 B7  30 00  00
    Increment BE  EF 03 06  00 DA  F4 04  00 B7  30 00  00
    Decrement BE  EF 03 06  00 0B  F5 05  00 B7  30 00  00
    COLOR TEMP 
    OFFSET B Reset Execute
    BE  EF 03 06  00 C8  C5 06  00 4C  70 00  00
    COLOR Get
    BE  EF 03 06  00 B5  72 02  00 02  22 00  00
    Increment BE  EF 03 06  00 D3  72 04  00 02  22 00  00
    Decrement BE  EF 03 06  00 02  73 05  00 02  22 00  00
    COLOR Reset ExecuteBE  EF 03 06  00 80  D0 06  00 0A  70 00  00
    TINT Get
    BE  EF 03 06  00 49  73 02  00 03  22 00  00
    Increment BE  EF 03 06  00 2F  73 04  00 03  22 00  00
    Decrement BE  EF 03 06  00 FE  72 05  00 03  22 00  00
    TINT Reset ExecuteBE  EF 03 06  00 7C  D1 06  00 0B  70 00  00
    SHARPNESS Get
    BE  EF 03 06  00 F1  72 02  00 01  22 00  00
    Increment BE  EF 03 06  00 97  72 04  00 01  22 00  00
    Decrement BE  EF 03 06  00 46  73 05  00 01  22 00  00
    SHARPNESS Reset ExecuteBE  EF 03 06  00 C4  D0 06  00 09  70 00  00
    MY MEMORY Load Set 1
    BE  EF 03 06  00 0E  D7 01  00 14  20 00  00
    2 BE  EF 03 06  00 9E  D6 01  00 14  20 01  00
    3 BE  EF 03 06  00 6E  D6 01  00 14  20 02  00
    4 BE  EF 03 06  00 FE  D7 01  00 14  20 03  00
    PRESET BE  EF 03 06  00 CE AD 01  00 14  20 10  00
    MY MEMORY Save Set 1
    BE  EF 03 06  00 F2  D6 01  00 15  20 00  00
    2 BE  EF 03 06  00 62  D7 01  00 15  20 01  00
    3 BE  EF 03 06  00 92  D7 01  00 15  20 02  00
    4 BE  EF 03 06  00 02  D6 01  00 15  20 03  00
    ASPECT Set4:3 BE  EF 03 06  00 9E  D0 01  00 08  20 00  00
    16:9 BE  EF 03 06  00 0E  D1 01  00 08  20 01  00
    14:9 BE  EF 03 06  00 CE  D6 01  00 08  20 09  00
    16:10 BE  EF 03 06  00 3E  D6 01  00 08  20 0A  00
    (*) NATIVE BE  EF 03 06  00 5E  D7 01  00 08  20 08  00 NORMAL BE  EF 03 06  00 5E  DD 01  00 08  20 10  00
    Get BE  EF 03 06  00 AD  D0 02  00 08  20 00  00
    OVER SCAN Get
    BE  EF 03 06  00 91  70 02  00 09  22 00  00
    Increment BE  EF 03 06  00 F7  70 04  00 09  22 00  00
    Decrement BE  EF 03 06  00 26  71 05  00 09  22 00  00
    OVER SCAN Reset ExecuteBE  EF 03 06  00 EC  D9 06  00 27  70 00  00
    V POSITION Get
    BE  EF 03 06  00 0D  83 02  00 00  21 00  00
    Increment BE  EF 03 06  00 6B  83 04  00 00  21 00  00
    Decrement BE  EF 03 06  00 BA  82 05  00 00  21 00  00
    V POSITION Reset ExecuteBE  EF 03 06  00 E0  D2 06  00 02  70 00  00
    (*) only for CP-WX2515WN/CP-WX3015WN
    (continued on next page) 
    						