11 When the projector connects network, the projector can be controlled with RS- 232C commands from the computer with web browser. For details of RS-232C commands, refer to RS-232C Communication / Network command table (&17). Command Control via the Network Connection 1. Turn off the projector and the computer. 2. If you use wired LAN, connect the projector's LAN port to the computer's LAN port with a LAN cable. Use the cable that fulfi lls the specifi cation shown in fi gure. If you use...
Page 12
12 Communication Port The following two ports are assigned for the command control.TCP #23 TCP #9715 Configure the following items form a web browser when command control is used. Port Settings Network Control Port1 (Port: 23) Port open Click the [Enable] check box to open [Network Control Port1 (Port: 23)] to use TCP #23. Default setting is “Enable”. Authentication Click the [Enable] check box for the [Authentication] setting when authentication is required. Default setting is “Disable”. Network...
Page 13
13 Command Control via the Network (continued) Command control settings [TCP #23] 1. Command format Same as RS-232C communication, refer to RS-232C Communicaton command format. 2. Response code / Error code ("h" shows hexadecimal) Four of the response / error code used for TCP#23 are the same as RS-232C Communication (1)~(4). One authentication error reply (5) is added. (1) ACK reply : 06h Refer to RS-232C communication ( &10). (2) NAK reply : 15h Refer to RS-232C communication ( &10)....
Page 14
14 2. Response code / Error code ("h" shows hexadecimal) The connection ID is attached for the TCP#23's response / error codes are used. The connection ID is same as the sending command format. (1) ACK reply : 06h + ××h (××h : connection ID) (2) NAK reoly : 15h + ××h (3) Error reply : 1Ch + 0000h + ××h (4) Data reply : 1Dh + xxxxh + ××h (5) Authentication error reply : 1Fh + 0400h + ××h (6) Projector busy reply: 1Fh + ××××h + ××h When the projector is too...
Page 15
15 This projector is equipped with NETWORK BRIDGE function. When the projector connects to the computer by wired or wireles LAN communicaton, an external device that is connected with this projector by RS- 232C communication can be controlled from the computer as a network terminal. For details, see the 6. Network Bridge function in the Network Guide. Network Bridge Communication NOTE • If data is transferred via wireless and wired LAN at the same time, the projector may not be able to process the...
Page 16
16 Communication settings For communication setting, use the OPTION - SERVICE - COMMUNICATION menu. ( &OPTION menu - SERVICE - COMMUNICATION in the Operating Guide ) Item Condition BAUD RATE 4800bps / 9600bps / 19200bps / 38400bps Data length 8 bit (fixed) PARITY NONE/ODD/EVENStart bit 1 bit (fixed)Stop bit 1 bit (fixed) Transmission method HALF-DUPLEX /FULL-DUPLEX NOTE • For connecting the projector to your devices, please read the manual for each devices, and connect them correctly with...
Page 17
17 RS-232C Communication / Network command table (continued on next page) RS-232C Communication / Network command table Names Operation Type Header Command Data CRC Action Type Setting Code Power Set Turn off BE EF 03 06 00 2A D3 01 00 00 60 00 00 Turn on BE EF 03 06 00 BA D2 01 00 00 60 01 00 Get BE EF 03 06 00 19 D3 02 00 00 60 00 00 [Example return] 00 00 01 00 02 00 [Off] [On] [Cool down] Input Source SetCOMPUTER IN1 BE EF 03 06 00 FE D2 01 00 00 20 00 00 COMPUTER...
Page 18
18 RS-232C Communication / Network command table (continued)(continued on next page) Names Operation Type Header Command Data CRC Action Type Setting Code BRIGHTNESS Get BE EF 03 06 00 89 D2 02 00 03 20 00 00 Increment BE EF 03 06 00 EF D2 04 00 03 20 00 00 Decrement BE EF 03 06 00 3E D3 05 00 03 20 00 00 BRIGHTNESS Reset Execute BE EF 03 06 00 58 D3 06 00 00 70 00 00 CONTRAST Get BE EF 03 06 00 FD D3 02 00 04 20 00 00 Increment BE EF 03 06 00 9B D3 04 00 04 20 00 00...
Page 19
19 RS-232C Communication / Network command table (continued) Names Operation Type Header Command Data CRC Action Type Setting Code User Gamma Point 6 Get BE EF 03 06 00 C4 FE 02 00 95 30 00 00 Increment BE EF 03 06 00 A2 FE 04 00 95 30 00 00 Decrement BE EF 03 06 00 73 FF 05 00 95 30 00 00 User Gamma Point 6 ResetExecuteBE EF 03 06 00 94 C2 06 00 55 70 00 00 User Gamma Point 7 Get BE EF 03 06 00 80 FE 02 00 96 30 00 00 Increment BE EF 03 06 00 E6 FE 04 00 96 30 00 00...
Page 20
20 RS-232C Communication / Network command table (continued) Names Operation Type Header Command Data CRC Action Type Setting Code COLOR TEMP OFFSET G Get BE EF 03 06 00 40 F5 02 00 B6 30 00 00 Increment BE EF 03 06 00 26 F5 04 00 B6 30 00 00 Decrement BE EF 03 06 00 F7 F4 05 00 B6 30 00 00 COLOR TEMP OFFSET G Reset Execute BE EF 03 06 00 BC C4 06 00 4B 70 00 00 COLOR TEMP OFFSET B Get BE EF 03 06 00 BC F4 02 00 B7 30 00 00 Increment BE EF 03 06 00 DA F4 04 00 B7 30...