RS-232C Communication / Network command table (continued) 31(continued on next page) Names Operation TypeHeaderCommand DataCRC Action Type Setting code MY IMAGESetOFF BE EF0306 00 3A C3 01 00 00 35 00 00 IMAGE-1 BE EF 0306 00 AA C2 01 00 00 35 01 00 IMAGE-2 BE EF 0306 00 5A C2 01 00 00 35 02 00 IMAGE-3 BE EF 0306 00 CA C3 01 00 00 35 03 00 IMAGE-4 BE EF 0306 00 FA C1 01 00 00 35 04 00 Get BE EF0306 00 06 00 06 00 00 35 00 00 MY IMAGE IMAGE-1 DeleteExecute BE EF0306 00 71 C3 06 0001 35 00 00 MY IMAGE IMAGE-2 DeleteExecute BE EF0306 00 35 C3 06 0002 35 00 00 MY IMAGE IMAGE-3 DeleteExecute BE EF0306 00 C9 C2 06 0003 35 00 00 MY IMAGE IMAGE-4 DeleteExecute BE EF0306 00 BD C3 06 00 04 35 00 00 VOLUME - ALL GetBE EF0306 00 CD C3 02 00 50 20 00 00 Increment BE EF 0306 00 AB C3 04 00 50 20 00 00 Decrement BE EF 0306 00 7A C2 05 00 50 20 00 00 LAN SOUND ENABLESet Disable BE EF 0306 00 BA F0 01 00 A3 20 00 00 Enable BE EF 0306 00 2A F1 01 00 A3 20 01 00 Get BE EF0306 00 89 F0 02 00 A3 20 00 00 USB TYPE A SOUND ENABLESet Disable BE EF 0306 00 CE F1 01 00 A4 20 00 00 Enable BE EF 0306 00 5E F0 01 00 A4 20 01 00 Get BE EF0306 00 FD F1 02 00 A4 20 00 00 USB TYPE B SOUND ENABLESet Disable BE EF 0306 00 32 F0 01 00 A5 20 00 00 Enable BE EF 0306 00 A2 F1 01 00 A5 20 01 00 Get BE EF0306 00 01 F0 02 00 A5 20 00 00
32 PJLink command PJLink command POWR Power Contorol0 = Standby 1 = Power On POWR ? Power Status inquiry 0 = Standby 1 = Power On 2 = Cool Down INPT Input Source selection 11 = COMPUTER IN 1 12 = COMPUTER IN 2 22 = S-VIDEO 23 = VIDEO 31 = HDMI 41 = USB TYPE A 51 = LAN 52 = USB TYPE B INPT ? Input Source inquiry 11 = COMPUTER IN 1 12 = COMPUTER IN 2 22 = S-VIDEO 23 = VIDEO 31 = HDMI 41 = USB TYPE A 51 = LAN 52 = USB TYPE B AVMT AV Mute10 = BLANK off 11 = BLANK on 20 = Mute off 21 = Mute on 30 = AV Mute off 31 = AV Mute on AVMT ? AV Mute inquiry 10 = BLANK off 11 = BLANK on 20 = Mute off 21 = Mute on 30 = AV Mute off 31 = AV Mute on Commands Control Description Parameter or Response (continued on next page)
33 PJLink command (continued) Commands Control DescriptionParameter or Response ERST ? Error Status inquiry1st byte: Refers to Fan error; one of 0 to 2 2nd byte: Refers to Lamp error; one of 0 to 2 3rd byte: Refers to Temptrature error; one of 0 to 2 4th byte: Refers to Cover error; one of 0 to 2 5th byte: Refers to Filter error; one of 0 to 2 6th byte: Refers to Other error; one of 0 to 2 The mearning of 0 to 2 is as given below 0 = Error is not detected; 1 = Warning; 2 = Error LAMP ? Lamp Status inquiry 1st number (digits 1 to 5): Lamp Time 2nd number : 0 = Lamp off, 1 = Lamp on INST ? Input Source List inquiry 11 12 22 23 31 41 51 52 NAME ? Projector Name inquiry Responds with the name set in "PROJECTOR NAME" of "NETWORK" INF1 ? Manufucturer's Name inquiry HITACHI INF2 ? Model Name inquiry CP-A222WN (8105B) CP-A302WN (8106B) CP-AW252WN (8104WB) INFO ? Other Information inquiry Responds with the factory information and so on CLSS ? Class Information inquiry 1 NOTE • The password used in PJLinkTM is the same as the password set in the Web Brouwser Comtrol. To use PJLinkTM without authentication, do not set any password in Web Browser Control. • For specifications of PJLink TM, see the web site of the Japan Business Machine and Information System Industries Association. URL: http://pjlink.jbmia.or.jp/ 430-8104WB–8105B-8106B-Technical-00 Note: Dukane models described in this document are manufactured by Hitachi and use the same firmware and software programs. The equivalent Dukane to Hitachi models are 8104WB (CP-AW252WN), 8105B (CP-A222WN), 8106B (CP-A302WN).