Dukane Imagepro 8104wb, 8105b, 8106b Operating Guide
Here you can view all the pages of manual Dukane Imagepro 8104wb, 8105b, 8106b Operating Guide. The Dukane manuals for Projector are available online for free. You can easily download all the documents as PDF.
Page 11
11 Command Control via the Network When the projector connects network, the projector can be controlled with RS- 232C commands from the computer with web browser. For details of RS-232C commands, refer to RS-232C Communication / Network command table (&17). Command Control via the Network LAN LAN LAN cable (CAT-5 or greater) NOTE • If data is transferred via wireless and wired LAN at the same time, the projector may not be able to process the data correctly. Connection 1. Turn off the projector and...
Page 12
12 Communicaion Port The following two ports are assigned for the command control.TCP #23 TCP #9715 Configure the following items form a web browser when command control is used. Port Settings Network Control Port1 (Port: 23) Port open Click the [Enable] check box to open [Network Control Port1 (Port: 23)] to use TCP #23. Default setting is “Enable”. Authentication Click the [Enable] check box for the [Authentication] setting when authentication is required. Default setting is “Disable”. Network...
Page 13
13 Command Control via the Network (continued) Command control settings [TCP #23] 1. Command format Same as RS-232C communication, refer to RS-232C Communicaton command format. 2. Response code / Error code ("h" shows hexadecimal) Four of the response / error code used for TCP#23 are the same as RS-232C Communication (1)~(4). One authentication error reply (5) is added. (1) ACK reply : 06h Refer to RS-232C communication ( &10). (2) NAK reply : 15h Refer to RS-232C communication ( &10)....
Page 14
14 2. Response code / Error code ("h" shows hexadecimal) The connection ID is attached for the TCP#23's response / error codes are used. The connection ID is same as the sending command format. (1) ACK reply : 06h + ××h (××h : connection ID) (2) NAK reply : 15h + ××h (3) Error reply : 1Ch + 0000h + ××h (4) Data reply : 1Dh + xxxxh + ××h (5) Authentication error reply : 1Fh + 0400h + ××h (6) Projector busy reply: 1Fh + ××××h + ××h When the projector is too...
Page 15
15 This projector is equipped with NETWORK BRIDGE function. When the projector connects to the computer by LAN communicaton, an external device that is connected with this projector by RS-232C communication can be controlled from the computer as a network terminal. For details, see the 6. Network Bridge Function - Network Guide. Network Bridge Communication Network Bridge Communication CONTROLRS-232C LAN LAN Connection 1. If you use wired LAN, connect the computer's LAN port and the...
Page 16
16 Communication settings For communication setting, use the OPTION - SERVICE - COMMUNICATION menu. ( &OPTION menu - SERVICE - COMMUNICATION in the User's Manual - Operating Guide ) Item Condition BAUD RATE 4800bps / 9600bps / 19200bps / 38400bps Data length 8 bit (fixed) PARITY NONE/ODD/EVEN Start bit 1 bit (fixed) Stop bit 1 bit (fixed) Transmission method HALF-DUPLEX/FULL-DUPLEX NOTE • For connecting the projector to your devices, please read the manual for each devices, and connect...
Page 17
17 RS-232C Communication / Network command table Names Operation TypeHeaderCommand DataCRC Action Type Setting code Power SetTurn off BE EF0306 00 2A D3 01 0000 60 00 00 Turn on BE EF0306 00 BA D2 01 0000 60 01 00 Get BE EF 0306 00 19 D3 02 0000 60 00 00 [Example return] 00 00 01 00 02 00 [Off] [On] [Cool down] Input SourceSetCOMPUTER IN1 BE EF 0306 00 FE D2 01 00 00 20 00 00 COMPUTER IN2 BE EF 0306 00 3E D0 01 00 00 20 04 00 HDMI BE EF 0306 00 0E D2 01 00 00 20 03...
Page 18
RS-232C Communication / Network command table (continued) 18(continued on next page) Names Operation TypeHeaderCommand DataCRC Action Type Setting code CONTRAST ResetExecute BE EF0306 00 A4 D2 06 00 01 70 00 00 GAMMASet1 DEFAULT BE EF 0306 00 07 E9 01 00 A1 30 20 00 1 CUSTOM BE EF 0306 00 07 FD 01 00 A1 30 10 00 2 DEFAULT BE EF 0306 00 97 E8 01 00 A1 30 21 00 2 CUSTOM BE EF 0306 00 97 FC 01 00 A1 30 11 00 3 DEFAULT BE EF 0306 00 67 E8 01 00 A1 30 22 00 3 CUSTOM BE EF...
Page 19
RS-232C Communication / Network command table (continued) 19(continued on next page) Names Operation TypeHeaderCommand DataCRC Action Type Setting code User Gamma Point 6 ResetExecute BE EF0306 00 94 C2 06 0055 70 00 00 User Gamma Point 7Get BE EF0306 00 80 FE 02 00 96 3000 00 Increment BE EF 0306 00 E6 FE 04 0096 30 00 00 Decrement BE EF 0306 00 37 FF 05 00 96 3000 00 User Gamma Point 7 ResetExecute BE EF0306 00 D0 C2 06 00 56 70 00 00 User Gamma Point 8Get BE EF0306...
Page 20
RS-232C Communication / Network command table (continued) 20(continued on next page) Names Operation TypeHeaderCommand DataCRC Action Type Setting code COLOR TEMP OFFSET G ResetExecute BE EF0306 00 BC C4 06 00 4B 70 00 00 COLOR TEMP OFFSET BGet BE EF0306 00 BC F4 02 00B7 30 00 00 Increment BE EF 0306 00 DA F4 04 00B7 30 00 00 Decrement BE EF 0306 00 0B F5 05 00B7 30 00 00 COLOR TEMP OFFSET B ResetExecute BE EF0306 00 C8 C5 06 004C 70 00 00 COLOR Get BE EF0306 00 B5...