Digital Projection Titan Hd-250 Specifications
Have a look at the manual Digital Projection Titan Hd-250 Specifications online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 577 Digital Projection manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

PERFORMANCE SPECIFICATIONS Brightness (±10%) 1,600 ANSI Lumens Contrast Ratio (±10%) >4000:1 Display Type 3 x DarkChip DMD™ with Fast Transit Pixels for smooth greyscale and improved contrast DMD Specification HD: 0.8” 1280 x 720 pixels native Sealed Optics at DMD™ Interface Protects DMD’s™ from optical contamination Source Compatibility • Composite, s-video, and color difference video standards • RGB graphics standards up to 1920 x 1080 • DVI standards • High definition RGB and color difference standards Video Processing • Class leading Video de-interlacing/processing of SD and HD sources using auto 3:2 and 2:2 extraction, ruggedized for editing discontinuities • Pixel-based motion adaptive interpolation • User selectable preset, parametric de-gamma and user downloadable de-gamma • Frame Delay: as low as 1 frame, source dependant • Auto mode selection - plug and play setup Network Connection LAN via RJ 45, Wireless 802.11b, full protocol feature setLamp Type High Intensity Discharge module Lamp Life (Typical) 11500 hours Lens Mount Motorized horizontal and vertical lens shif t, zoom and focus Lens Shift (maximum) Fixed lenses on HD: On axis only Zoom lenses on HD: Vert: +0.5, -0.16 frame; Hor: ±0.1 frame Lens Options 0.64 :1 fixed 0.96 :1 fixed 1.2-1.44 :1 zoom 1.44-1.8 :1 zoom 1.8-2.4 :1 zoom 2.4-3.6 :1 zoom 3.6-5.6 :1 zoom Mechanical Mounting Front or rear table Front or rear ceiling (ceiling mount optional) Integrated Handles Dimensions (including feet) 24.25in(L) x 20.7in(W) x 10.7in(H) 616mm(L) x 525mm(W) x 271mm(H) Weight (chassis only) 53 lbs (24 kg) HD-250 Digital Projection International (DPI), Texas Instruments first DLP™ partner and the original inno- vator of the 3-chip DLP™ projector, proudly intro- duces our newest high performance, value-driven Home Cinema display, the TITAN HD-250. Weighing in at just 53 lbs. (24 kg.), the 3-chip DLP™ TITAN HD-250 employs the latest in DPI’s illumina- tion, optics and electronics technology. Delivering 1,600 ANSI lumens and a stunning 4000:1 contrast ratio, the TITAN HD-250 is perfect for home cinemas with screens up to 15’ wide. Dark Chip technology, by Texas Instruments, assures the broad gamut of deeply saturated colors that only a 3-chip DLP display can produce. Equipped with Digital Projection’s next-generation electronics, the TITAN HD-250 provides class-lead- ing motion-adaptive interpolation as well as state- of-the-art video de-interlacing. SD and HD sources are processed using auto 3:2 and 2:2 extraction. Other key benefits of the TITAN HD-250 include: • A wide range of zoom lenses – all with extensive horizontal and vertical lens shif t capability • Ultra quiet – less than 35dBA – audibly invisible in most entertainment venues • Sealed optics - protects the DMDs and other focal plane components from airborne contaminants • Class leading, next generation electronics with six user-selectable inputs, including HDCP compliant DVI • High Intensity Discharge (HID) lamp with a typical life of 1500 hours and low cost of replacement With its rugged construction, extensive source com- patibility and the proven reliability of DLP technology, the TITAN HD-250 is an unmatched imaging tool for creating stellar home cinema entertainment and home media experiences. The TITAN HD-250, a highly engineered and pre- cisely craf ted 3-chip DLP TMdisplay - priced and sized to bring the beauty of Digital Projection to your home venue. Specifications subject to change without notice DP V1.06/06 ©2006 Digital Projection, Inc. ™DLP, Digital Light Processing and DMD are trademarks of Texas Instruments, Inc. INPUT CAPABILITIES Type Composite S-Video Component Interlaced/Std def Y, Cr/Pr, Cb/Pb, S Graphics Progressive RGB/Progressive Interlaced Hi def Y, Cr/Pr, Cb/PB RGBHV (Progressive) Digital RGB Connector BNC 4-pin mini DIN BNCx4 BNCx5 D sub (15-pin) DVIQuantity 1 1 1 1 1 1 PRELIMINARY SPECIFICATIONS

DIGITAL PROJECTION, INC. • 55 CHASTAIN ROAD. SUITE 115. KENNESAW. GA. 30144 • P-770.420.1350 • F-770.420.1360 • www.digitalprojection.com DIGITAL PROJECTION, LTD. • GREENSIDE WAY. MIDDLETON. MANCHESTER. UK. M24 IXX • P-+44.161.947.3300 • F-+44.161.684.7674 • www.digitalprojection.co.uk Native Color Temperature HDTV Formats Supported Scan Rates Supported Remote Control Automation Control Operating/Storage Temperature Operating Humidity Thermal Dissipation Fan Noise Power Requirements Power Consumption ADVANCED TECHNICAL SPECIFICATIONS PARAMETER 6500°K ±1000°K; white balance-adjustment: 3000°K to 9000°K (With integral color optimization notch filter) 1080i (50Hz, 60Hz), 1080p (24Hz, 25Hz, 30Hz, 50Hz, 60Hz), 1080 24sf, 720p (50, 60Hz), 480i, 480p Horizontal: 15kHz to 100kHz / Vertical: 24Hz to 85Hz Addressable IR remote control, wireless and wired with loop-through On board invertable keypad LAN connection via RJ45 (ASCII Protocol) / RS232 9-pin D type (Hex Protocol) Operating: 0 to 40°C / Storage: -10 to 50°C 20 to 80% non-condensing 1733 BTU Less than 35 dBA 100-240 VAC ±10%, 50/60Hz single phase 500 Watts PROJECTOR TITAN HD-250 PART NO. Replacement lamp Rigging Frame Ceiling mount Infrared remote (replacement) LENSESPART NO. ACCESSORIESPART NO. 106-240 102-246 104-923 105-021 105-023 Projector dimensions (in)W120.7 H110.7 L124.25 TITAN HD-250 side view 1 Based on 4-6 hour/day operational profile. Venue and application conditions may impact actual lamp life. See Digital Projection’s Product Warranty Statement for details on lamp warranty. 001-734 001-735 001-736 001-737 001-738 001-739 001-740 0.64 :1 fixed 0.96 :1 fixed 1.2-1.44:1 zoom 1.44-1.8:1 zoom 1.8-2.4 :1 zoom 2.4-3.6 :1 zoom 3.6-5.6 :1 zoom Projector dimensions (mm) W1525 H1271 L1616

TOTALZONE® ADD-A-ZONE™(TAZ-4) ZONE CONTROL PANEL 3 69-1366-2 Fig. 2. Wiring Add-A-Zone panel. ZONE DAMPER MOTORS M1 - common M4 - power open M6 - power closed DIP SWITCH SETTINGS 1 = ON 0 = OFF 12 345 N1N2N3N40 0 1 0 1 ZONES 5 6 7 8 0 0 1 1 0 ZONES 6 7 8 9 0 0 1 1 1 ZONES 7 8 9 10 0 1 0 0 0 ZONES 8 9 10 11 0 1 0 0 1 ZONES 9 10 11 12 0 1 0 1 0 ZONES 10 11 12 13 0 1 0 1 1 ZONES 11 12 13 14 0 1 1 0 0 ZONES 12 13 14 15 0 1 1 0 1 ZONES 13 14 15 16 0 1 1 1 0 ZONES 14 15 16 17 0 1 1 1 1 ZONES 15 16 17 18 1 0 0 0 0 ZONES 16 17 18 19 1 0 0 0 1 ZONES 17 18 19 20 1 0 0 1 0 ZONES 18 19 20 21 1 0 0 1 1 ZONES 19 20 21 22 1 0 1 0 0 ZONES 20 21 22 23 1 0 1 0 1 ZONES 21 22 23 24 1 0 1 1 0 ZONES 22 23 24 25 1 0 1 1 1 ZONES 23 24 25 26 1 1 0 0 0 ZONES 24 25 26 27 1 1 0 0 1 ZONES 25 26 27 28 1 1 0 1 0 ZONES 26 27 28 29 1 1 0 1 1 ZONES 27 28 29 30 1 1 1 0 0 ZONES 28 29 30 31 1 1 1 0 1 ZONES 29 30 31 32 ZONE LEDsON Damper open or opening OFF Damper closed or closing MOMENTARY PUSH BUTTONBoot — Clears microprocessor BOOT 1 “C” terminal connection is not required on battery powered, power stealing, or some electromechanical thermostats. 2 Leave jumper disconnected for “B” type or conventional thermostats. Connect jumper for “O” type thermostats. R C T1 T2 AZ2 AZ1 This diagram shows the typical thermostat and damper motor connections. For specific wiring for other thermostats and damper motors, refer to the Installation Instructions. M6 M4 M1 1 Zone 4 Thermostat CR C R Power-closed Spring-open (Model ZBD, ZDS, or ARD-PC)Power-open Spring-closed (Model ARD-PO)Power-open Spring-closed (Model ARD-PO) 24VAC, 40VA Transformer (Required if more than four dampers) 24VAC, 40VA Transformer AZ1 AZ2Add-A-Zone Panel(s) Add-A-Zone or TZ Panel(s) DAMPER XFRMPANEL XFRM Minneapolis, MN 55422 www.honeywell.com/yourhome ZONE N1ZONE N2COMMZONE N3ZONE N4 DIP SWITCH 1 O N2345 M6 M4 M1 1 Zone 3 Thermostat M6 M4 M1 1 Zone 2 Thermostat 456Z 123X Power-open Power-closed (Opposed Blade Damper Motors) O/B Y2 GW2M6M4M1W3/ AUXY1W1/ ERC Y1 W3/ AUX W2 W1/ E R CY2GLO/B Y1 W3/ AUX W2 W1/ E R CY2GLO/B Y1 W3/ AUX W2 W1/ E R CY2GLO/B Y1 W3/ AUX W2 W1/ E R CY2GLO/B LO/B Y2 GW2W3/ AUX Y1 W1/ E R C LO/B Y2 GW2W3/ AUX Y1 W1/ E R C LO/B Y2 GW2W3/ AUX Y1 W1/ E R C L 1 Zone 1 Thermostat ZONE 12ThermostatDamperZONE 22ThermostatDamperZONE 32ThermostatDamperZONE 42ThermostatDamper M20363

69-1366-2 G.H. Rev. 02-02 www.honeywell.com/yourhome TOTALZONE® ADD-A-ZONE™(TAZ-4) ZONE CONTROL PANEL Automation and Control SolutionsHoneywell Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Scarborough, Ontario M1V 4Z9 Printed in U.S.A. on recycled paper containing at least 10% post-consumer paper fibers. TECHNICAL SUPPORT For Internet access: www.trolatemp.com or www.honeywell.com/yourhome/zoning/zoning_home.htm Call 1-800-828-8367 for zoning technical support line. To download Zoning literature: http://hbctechlit.honeywell.com