Home > Digital Projection > Projector > Digital Projection Lightning 38 Sx+ 3d User Manual

Digital Projection Lightning 38 Sx+ 3d User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Digital Projection Lightning 38 Sx+ 3d User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 577 Digital Projection manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							english
    51
    Select the target folder to which the data should be saved and press “Start”. When all files 
    are copied to the control PC, click “Done”. Each unit the system will have to be upgraded\
     
    separately. For revision tracking of the calibration data, each new backup folder should \
    con-
    tain the date and time of the backup.
    To restore the calibration files to the multi image processor unit, select “Restore Calibration 
    files..” from the file menu. The window in Figure 10-4 appears.
    Figure 10-4.  Restore calibration from control PC
    Locate the calibration to be restored, and press “Start”. All calibration files from the selected 
    backup folder will be copied to the multi image processor unit.    
    						
    							english
    52FUSION – Storing and recalling data
    10.3 Accept calibration
    After a calibration has been completed and the result verified in online state, the calibration 
    must be accepted.
    When a calibration is accepted for one resolution the binary data is stored in the FUSION unit 
    and will be loaded automatically every time the unit starts up or the resolution is changed to 
    current. The calibration must be accepted in each resolution.
    If no accepted file is available for the actual resolution the unit will go to bypass state when it 
    starts up.
    It is only possible to activate an accepted file if it is generated fo\
    r the correct resolution.
    See  Figure 10-5 for administration of accepted files.
    - Select “Accept” to accept the current configuration.
    - Select “Accept as” to save it to another name.
    - Select “Check Auto State” to activate the current accepted file and verify the start up behaviour.
    - “Accepted Files Adminitration” allows the user to copy, rename, delete and activate  accepted files.
    Figure 10-5.  Accept calibration   
    						
    							english
    53
    11 Technical specifications
    11.1 Electrical
    versions00 110-585 (FUSION MDP3D) 00 110-584 (FUSION MDP)
    functionalityGeometry Correction, Blending, Colour Correction and matching, Uniformity Correction and matching
    scalabilityUnlimited channels
    latencyZero with simple blended set up, rotation dependent with geometry correction
    internal colour depth12 bits per colour
    I/ODual Link DVI in / out Ethernet (control) IEC power connector
    black level correctionPatented Pixel Level Matching; individual RGB channel on pixel level
    maximum resolution2560 x 1600 (FUSION MDP3D) 1920 x 1200 (FUSION MDP)
    3D stereographic1920 x 1200@ 120 Hz on FUSION MDP3D 1280 x 800 @ 120 Hz on FUSION MDP
    setup and controlFusionNet setup and calibration tool Automatic Camera setup (tba.)
    filtering and scaling options – user selectable4x4 Lanzcos algorithm Bi-cubic interpolation Bi-linear interpolation
    installation1/2 width. 1RU rack mount. Rack mounting kit available
    conformancesFCC Class A, CE, CUL
    power requirements100 - 120VAC, 200 - 240 VAC, 50/60 Hz, < 30W
    size ( H x W x D)43.5 x 216 x 275.5 mm
    All specifications are subject to change without prior notice.    
    						
    							english
    54FUSION – Technical specifications
    11.2 Mechanical   
    						
    							english
    55
    12 Table of figures
    Figure 4-1.  FUSION processing system overview 12
    Figure 4-2.  Connector panel 12
    Figure 4-3.  Front button and LED-indicators 13
    Figure 4-4.  Rack mount plate 14
    Figure 4-5.  Rack mounted 14
    Figure 5-1.  Overview of ProNet.site 15
    Figure 5-2.  FUSION calibrator, Device View. 16
    Figure 5-3.  File menu, Device View. 17
    Figure 5-4.  The Device Tree in the Device Pool. 17
    Figure 5-5.  Toolbars, shown with and without help texts. 18
    Figure 5-6.  Clearing calibration 19
    Figure 5-7.  Application and Network settings. 19
    Figure 5-8.  FUSION software upgrade window. 20
    Figure 5-9.  EDID Administration. 20
    Figure 5-10.  Switching views from Calibrator view to Device view and ba\
    ck. 21
    Figure 5-11.  Calibration toolbar, without and with help texts. 21
    Figure 5-12.  FUSION Navigator 22
    Figure 5-13.  Top toolbar window navigation 22
    Figure 5-14.  Calibration Panel Toolbar, without and with help texts. 23
    Figure 5-15.  Set colors control box 24
    Figure 5-16.  Control point setup 24
    Figure 5-17.  Bezier point settings 25
    Figure 6-1.  Warping algorithm setup 28
    Figure 6-2.  Scaling filters 29
    Figure 6-3.  Working with the perspective transform 30
    Figure 6-4.  Working with the Mesh Transform algorithm 31
    Figure 6-5.  Mesh Bezier with 1x1 grid 32
    Figure 6-6.  Working with Mesh Bezier, simple mapping 33
    Figure 6-7.  Real time warp state 33
    Figure 6-8.  Calibration panel guide points 34
    Figure 7-1.  Basic edge blending. 36
    Figure 7-2.  Adding a blend zone. 37
    Figure 7-3.  Add blend zone window. 38
    Figure 7-4.  Working with advanced edge blending. 38
    Figure 7-5.  Adjusting the blend drop off curve. 39
    Figure 7-6.  Drop-off curve setup 40
    Figure 8-1. Start BLM tool. 41
    Figure 8-2. Adding Black Level Management lines. 42
    Figure 8-3. Multiple Black Level Management lines added. 42
    Figure 8-4. Adjusting black level. 43
    Figure 9-1.  Starting the clip tool 45
    Figure 9-2.  Adding the first line in a clip area. 46
    Figure 9-3.  Adding multiple side in a clip area. 47
    Figure 9-4.  Clipping area complete. 48
    Figure 10-1.  Save current calibration to the FUSION unit 49
    Figure 10-2.  Backup up calibration data. 50
    Figure 10-3.  Selecting folder for backup 50
    Figure 10-4.  Restore calibration from control PC 51
    Figure 10-5.  Accept calibration 52    
    						
    							english
    56FUSION – Table of figures   
    						
    							601-212-01
    digital projection  locations
    North America Corporate Headquarters
    Digital Projection, Inc.
    55 Chastain Road, NW, Suite 115
    Kennesaw, GA 30144
    (P) 770.420.1350
    (F) 770.420.1360
     
    Worldwide Headquarters
    Digital Projection Ltd.
    Greenside Way,
    Middleton,
    Manchester
    M24 1XX
    (P) +44 (0) 161 947 3300
    (F) +44 (0) 161 684 7674
     
    China Corporate Headquarters
    DP China
    Rm C1202,Cai Fu Jia Yuan,No.19
    Xiao Ying Street, Chaoyang District,Beijing 100101,PR China
    (P) (8610)010-58239771/ 72    
    (F) 010-58239770
    Asia Corporate Headquarters
    DP Asia
    16 New Industrial Road
    #02-10 Hudson Technocentre
    Singapore 536204
    (P) 65-6284-1138
    (F) 65-6284-1238
    www.digitalprojection.com 
    						
    All Digital Projection manuals Comments (0)

    Related Manuals for Digital Projection Lightning 38 Sx+ 3d User Manual