RFScada 8ADI-9DO/4ADI-5DO Manual Ver 3.6 Copyright ©2005 Data Delivery Devices LLC Page - 91 – Bartlesville OK Tel 918-335-3318 FAX 918-398-9990 Register 614 contains the Modbus ‘silent interval’ time setting, in milliseconds. Modbus RTU messages start and end with a silent interval of at least 3.5 character times, which for a baud rate of 9600 bps is approximately 4mS. The RFScada units are capable of reading the Modbus message, acting on the message, formulating a reply, then start...
Page 92
RFScada 8ADI-9DO/4ADI-5DO Manual Ver 3.6 Copyright ©2005 Data Delivery Devices LLC Page - 92 – Bartlesville OK Tel 918-335-3318 FAX 918-398-9990 Register 1003 contains the software version of the RFScada unit, again read only. Units do not need to have identical software versions to communicate. Registers 1004 to 1013 contain additional factory settings that are specific to the type of radio installed. Register 3318 is the Modbus and configuration settings control register. All Modbus registers...
Page 93
RFScada 8ADI-9DO/4ADI-5DO Manual Ver 3.6 Copyright ©2005 Data Delivery Devices LLC Page - 93 – Bartlesville OK Tel 918-335-3318 FAX 918-398-9990 24 Unit 2 Analog 4 10 bit result. 0 = 0 mA, 1023 = 20mA 25 Unit 2 Analog 5 10 bit result. 0 = 0 mA, 1023 = 20mA 26 Unit 2 Analog 6 10 bit result. 0 = 0 mA, 1023 = 20mA 27 Unit 2 Analog 7 10 bit result. 0 = 0 mA, 1023 = 20mA 28 Unit 2 Analog 8 10 bit result. 0 = 0 mA, 1023 = 20mA 29 Unit 2 DC Voltage 10 bit, 1023 = 51.1 Volts DC (approx)...
Page 94
RFScada 8ADI-9DO/4ADI-5DO Manual Ver 3.6 Copyright ©2005 Data Delivery Devices LLC Page - 94 – Bartlesville OK Tel 918-335-3318 FAX 918-398-9990 94 Unit 9 Analog 4 10 bit result. 0 = 0 mA, 1023 = 20mA 95 Unit 9 Analog 5 10 bit result. 0 = 0 mA, 1023 = 20mA 96 Unit 9 Analog 6 10 bit result. 0 = 0 mA, 1023 = 20mA 97 Unit 9 Analog 7 10 bit result. 0 = 0 mA, 1023 = 20mA 98 Unit 9 Analog 8 10 bit result. 0 = 0 mA, 1023 = 20mA 99 Unit 9 DC Voltage 10 bit, 1023 = 51.1 Volts DC (approx)...
Page 95
RFScada 8ADI-9DO/4ADI-5DO Manual Ver 3.6 Copyright ©2005 Data Delivery Devices LLC Page - 95 – Bartlesville OK Tel 918-335-3318 FAX 918-398-9990 164 Unit 16 Analog 4 10 bit result. 0 = 0 mA, 1023 = 20mA 165 Unit 16 Analog 5 10 bit result. 0 = 0 mA, 1023 = 20mA 166 Unit 16 Analog 6 10 bit result. 0 = 0 mA, 1023 = 20mA 167 Unit 16 Analog 7 10 bit result. 0 = 0 mA, 1023 = 20mA 168 Unit 16 Analog 8 10 bit result. 0 = 0 mA, 1023 = 20mA 169 Unit 16 DC Voltage 10 bit, 1023 = 51.1 Volts DC (approx)...
Page 96
RFScada 8ADI-9DO/4ADI-5DO Manual Ver 3.6 Copyright ©2005 Data Delivery Devices LLC Page - 96 – Bartlesville OK Tel 918-335-3318 FAX 918-398-9990 234 Unit 23 Analog 4 10 bit result. 0 = 0 mA, 1023 = 20mA 235 Unit 23 Analog 5 10 bit result. 0 = 0 mA, 1023 = 20mA 236 Unit 23 Analog 6 10 bit result. 0 = 0 mA, 1023 = 20mA 237 Unit 23 Analog 7 10 bit result. 0 = 0 mA, 1023 = 20mA 238 Unit 23 Analog 8 10 bit result. 0 = 0 mA, 1023 = 20mA 239 Unit 23 DC Voltage 10 bit, 1023 = 51.1 Volts DC (approx)...
Page 97
RFScada 8ADI-9DO/4ADI-5DO Manual Ver 3.6 Copyright ©2005 Data Delivery Devices LLC Page - 97 – Bartlesville OK Tel 918-335-3318 FAX 918-398-9990 304 Unit 30 Analog 4 10 bit result. 0 = 0 mA, 1023 = 20mA 305 Unit 30 Analog 5 10 bit result. 0 = 0 mA, 1023 = 20mA 306 Unit 30 Analog 6 10 bit result. 0 = 0 mA, 1023 = 20mA 307 Unit 30 Analog 7 10 bit result. 0 = 0 mA, 1023 = 20mA 308 Unit 30 Analog 8 10 bit result. 0 = 0 mA, 1023 = 20mA 309 Unit 30 DC Voltage 10 bit, 1023 = 51.1 Volts DC (approx)...
Page 98
RFScada 8ADI-9DO/4ADI-5DO Manual Ver 3.6 Copyright ©2005 Data Delivery Devices LLC Page - 98 – Bartlesville OK Tel 918-335-3318 FAX 918-398-9990 374 Unit 13 Relay 5 & 6 digital source byte, LS byte = Relay 5; MS 5 bits = source ID, LS 3 bits = source channel 375 Unit 13 Relay 7 & 8 digital source byte, LS byte = Relay 7; MS 5 bits = source ID, LS 3 bits = source channel 376 Unit 14 Relay 1 & 2 digital source byte, LS byte = Relay 1; MS 5 bits = source ID, LS 3 bits = source channel 377...
Page 99
RFScada 8ADI-9DO/4ADI-5DO Manual Ver 3.6 Copyright ©2005 Data Delivery Devices LLC Page - 99 – Bartlesville OK Tel 918-335-3318 FAX 918-398-9990 444 Unit 31 Relay 1 & 2 digital source byte, LS byte = Relay 1; MS 5 bits = source ID, LS 3 bits = source channel 445 Unit 31 Relay 3 & 4 digital source byte, LS byte = Relay 3; MS 5 bits = source ID, LS 3 bits = source channel 446 Unit 31 Relay 5 & 6 digital source byte, LS byte = Relay 5; MS 5 bits = source ID, LS 3 bits = source channel 447 Unit 31...
Page 100
RFScada 8ADI-9DO/4ADI-5DO Manual Ver 3.6 Copyright ©2005 Data Delivery Devices LLC Page - 100 – Bartlesville OK Tel 918-335-3318 FAX 918-398-9990 514 Unit 16 Analog 5 & 6 output source bytes, LS byte = Analog 5; MS 5 bits = source ID, LS 3 bits = source channel 515 Unit 16 Analog 7 & 8 output source bytes, LS byte = Analog 7; MS 5 bits = source ID, LS 3 bits = source channel 516 Unit 17 Analog 1 & 2 output source bytes, LS byte = Analog 1; MS 5 bits = source ID, LS 3 bits = source channel...