20 OPERATION AND FUCTIONS CONTENTS REMARKS 1. Fan voltage of each control mode 2. Control against (under) load (Load Control) 1) Purpose : To restore F/R-temperature which has risen by load (much foods in or frequent door openings) as soon as possible 2) Display : SPEED lights until the mode and speed icons flicker. 3) Conditions to start (from both Normal and Silence) F or R door open time exceeds 30 seconds at a time Freezer and Refrigerator load control starts respectively. Over [F-sensor On Point + 5 degree] F load control Over [R-sensor On Point + 5 degree] R load control 4) Conditions to avoid load control Initial operation (right after pow Just after Pre-cool, Heater defrosting, Pause, Defrosting cycle (After door opening, the load control enters if the condition complies with.) (During Sleep Mode1, load control isn t active.) 5) Control Method 5-1) Control mode by F/R-door open time (over 30 seconds) F/R-fan works by 14V respectively. 5-2) Control mode by [F-sensor On Point + 5 degree] F-fan works by 14V. 5-3) Control mode by [R-sensor On Point + 5 degree] R-fan works by 14V. C-fan works by 10V as normal. 6) Conditions to stop The mode works for 20 minutes. (If another condition happens at the end of the mode, it starts again.) When it reaches to [F-sensor Off point], F-fan load control mode stops. When it reaches to [R-sensor Off point], R-fan load control mode stops. Control Mode F-FAN R-FAN C-FAN Normal 12V 12V Normal 14V 14V Load Control Silence 12V 12V Silence Normal 10V 10V Normal 10V 10V Sleep Mode2 Load control 12V 12V 10V ! ! ! @ @ @ # #
21 OPERATION AND FUCTIONS CONTENTS REMARKS 3. Control Time Chart of Each Mode 1) Start & stop of load control mode (Normal Control) Door F/ S F Fan R/ S R Fan Door Open30 sec. af ter OpenLoad Mode StartFrz. Load StopRez. Load Stop On + 5deg On + 5deg Frz. Overl oad InputFrz. Start Condition Frz. Stop ; after 20mi n. 20min. 20min. Ref. Load 14V 14V 12V 12V 2) Start & stop of load control mode (Silence Control) Door F/S F Fan R/S R Fan Door Open30sec. after openLoad Mod e St artRef . Lo ad StopFrz. Loa d St op On + 5deg On + 5deg Frz. Overload InputFrz. Loa d Start Frz. St op Co nd ition ; after 20min. 20min. 20min. Ref . Lo ad 12V 12V 10V 8V 3) Start & stop of load control mode (Normal defrosting control) F/S F Fan R/S R Fan Defrosting Start Condition to start Load Mode , but avoided buring defrosting m odeRef. Loa d Stop On + 5degN o rm a l O p e ra tio n 20m in. Ref. Load Mode 14V 12V 8V HTR Comp
22 OPERATION AND FUCTIONS CONTENTS REMARKS 4. Flow Chart of Load Control Mode Sart F/R door open time is over 30 sec. ? F/S ON + 5deg? R-sensor ON + 5deg? Fan RPM F Fan : 12V R Fan : 12V C Fan : 10VFan RPM Normal Overload F Fan : 10V 12V R Fan : 10V 12V C Fan : 10V 12V Overload of both compartments Y N Freezer Compartment Overload Refrigerator Compartment Overload Y N Y N F load control ; over 20 min. ? F-sensor OFF point ? Overload mode control Overload mode ? Normal mode control N F load control mode stop R-sensor OFF point ?R load control mode stop End Load control is avoided ? N Y R load control ; over 20 min. ? Y Y Y N Y N N Y N Control Mode Normal 240 minutes ?N Silence
23 OPERATION AND FUCTIONS Defrosting Cycle INPUT Control Object 1. Total comp. work time 2. Comp. work rate 3. RT temperature 4. Total door open time 1. Defrosting Mode CONTENTS REMARKS 1. Conditions to start defrosting cycle 1) Total comp. work time : 6, 8, 10 hours 2) Comp. work rate (by the 2 hours) : over 65% 3) Total door open time : 3 minutes (Any door - F or R - open time is over 3 minutes.) 4) Total time of [comp. ON + comp. OFF] : 60 hours 5) Ambient temperature : over 35 6) Any error mode : R1, F1, D1, F3, RT/S, Door-switch 2. Conditions to start defrosting mode 1) The mode starts in the following conditions ; Any error happens when total comp. work time is 6 or 8 or 10 hours. Comp. work rate by the 2 hours is over 65%. Total door open time is over 3 minutes. (Any door - F or R - open time is over 3 minutes.) Ambient temperature is over 35 . 2) Defrosting mode starts unconditionally as long as total comp. work time is 10 hours, even if the above conditions( ~$) are not satisfied. 3) Defrosting mode starts immediately as long as total time of [comp. ON + comp. OFF] is over 60 hours, even if the above 1) and 2) conditions are not satisfied. C C ! @ ! #
24 OPERATION AND FUCTIONS CONTENTS REMARKS 3. Flow Chart of Defrosting Start Start Ambient temp. is over 35 ? Comp. work time is over 10 hours ? Total time is over 60 hours ? Comp. work time is over 6 hours ? Any error ? Comp. work rate is over 65 % ? EndDefrosting mode starts. Yes Yes Yes Yes Yes Yes No No No No No NoComp. work time is over 2 hours ? Total door open time is over 3 minutes ? Yes Yes No No Comp. work time is over 8 hours ? No No
25 OPERATION AND FUCTIONS Defrosting Mode INPUT Control Object 1. Defrosting Cycle 1. COMP 2. F-FAN 3. R-FAN 4. HEATER CONTENTS REMARKS 1. Defrosting Mode 1) Time ; 50 minutes 2) Comp. / F-fan : ON R-fan : Control Heater : OFF 3) If F-sensor≤- 27 , PRE-COOL becomes OFF. 1) If D-sensor ≥10 , Heater becomes OFF. 2) In case of Heater return by time limit of 40 or 80 min (F3-Error) 3) Heater is ON for 30 minutes (time limit) in case of D- sensor error. 4) Time limit 30 seconds : Heater is ON regardless of D-sensor temperature right after defrosting start. 30 minutes : in case of D1-Error 80 minutes : in normal control state 1) Time : 7 minutes Comp., F-fan, R-fan, Heater : OFF 1) Time : 5 minutes Comp. : ON F/R-fan, Heater : OFF Output control and time limit of each defrosting mode PRE-COOL Heater Defrosting Pause Fan Delay COMP ON OFF OFF ON F-FAN ON OFF OFF OFF R-FAN Co ntrol OFF OFF OFF HEATER OFF ON OFF OFF Time Limit 50 min. 80 min. 30 min. (in case of D1-Error) 7 min. 5 min. C-fan and comp. are linked. Pre-Cool Heater Defrosting Pause Fan Delay ! @ C C ! @ #
26 OPERATION AND FUCTIONS Error Display (LCD Display of F-PCB) E1 I sensor; disconnection, short EF FLOW sensor; disconnection, short Et Level sensor sw error E9 Water supply Error EA Continuously Ice drop 3times at Et. Eu Fully Ice sensor sw error INPUT Control Object 1. Temperature Control Buttons CUSTOM LCD CONTENTS REMARKS 1. How to start 1) Set LOCK ON first. 2) Push Refrigerator Set button 5 times while pushing Freezer Set button. 2. Display Error code is displayed on Freezer temperature display part. 3. How to stop 1) Push LOCK button 3 times while pushing REF SET. button. 2) It stops automatically 4 minutes after the start. 4. All the error Ccdes are reset if they turn to be normal. 5. Error Code ERROR CODE CONTENTS F1 F-sensor ; disconnection, short(pull-down) r1 R-sensor ; disconnection, short(pull-down) rt RT-sensor ; disconnection, short(pull-down) d1 D-sensor ; disconnection, short(pull-down) dr R-Door Switch ; defective dF F-Door Switch ; defective dH Homebar (Refreshment Center) Door Switch ; defective C1 Cycle ; abnormal or defective. F3 Return after defrosting ; abnormal or defective d2 Forced defrosting mode for A/S
27 OPERATION AND FUCTIONS CONTENTS REMARKS 6. Control Way of Errors (if any) 1) F1 ERROR Cause : F-sensor disconnection / short (pull-down) Control : Comp. / F-fan ON for 25min., OFF for 25min. if F-sensor is normal, the error is terminated automatically. 2) r1 ERROR Cause : R-sensor disconnection / short (pull-down) Control : Condition of ambient temperature RT/S In ERROR ~13 14 ~19 20 ~29 29 ~ Work rate ON/OFF 8 / 12 7 / 13 8 / 12 8 / 12 9 / 11 If R-sensor is normal, the error is terminated automatically. 3) rt ERROR Cause : RT-sensor disconnection / short (pull-down) Control : Normal operation, deletion of control condition by RT-sensor If RT-sensor is normal, the error is terminated automatically. 4) d1 ERROR Cause : D-sensor disconnection / short (pull-down) Control : Time limit (30min.) of defrosting-return If D-sensor is normal, the error is terminated automatically. 5) Door ERROR(dF,dR,dH on display) Cause : in case it senses that door is open for more than 1 Control : Deletion of function related door switch sensing If door switch (open & close) is sensed, the error is terminated automatically. After displaying on LCD the mode is terminated. 6) C1 ERROR Cause : in case comp. works for over 3 hours when D-sensor temp. is over -5 Control : Normal operation When D-sensor temp. is below -5 in comp. OFF, it is terminated. 7) F3 ERROR Cause : in case defrosting-return is done by time limit of 80min. Control : Deletion of Pre-cool mode in defrosting mode If defrosting-return is done by D-sensor, it is terminated. 8) d2 MODE (A/S forced defrosting mode) Set LOCK ON first, then push REFRIGERATOR SET. button 5 times while pushing FREEZER SET. button simultaneously. Control : A/S forced defrosting control (Pre-cool is deleted.) If D-sensor temp. is over 10 , the mode is terminated automatically. C C C C C C C C C ! @ # ! @ # ! @ # ! @ # ! @ # ! @ # $
28 OPERATION AND FUCTIONS 9) EI ERROR Cause : I-SENSOR disconnection / short (pull-down) Control : After water suppy, Ice drop every 4.8hour. Termination : When I-SENSOR is normal. 10) Ft ERROR Cause : When Level SW is ERROR Control : Time control (Skip water supply mode) Termination : Normal 11) EF Error Cause : When Flow-sensor is ERROR(There is no Pulse during some time.) When water supply valve is ON , Pulse input is below 10 during 1s. Control : Time control(By Vector time recorded EEPROM.) (Generally, Water is supplied about 5.5s.) Termination : Exchang Flow-Sensor. 12) Eg Error Cause : I-Sensor temp(5M after Water supply) dosen t get high. Control : Normal control Termination : Normal 13) Dispenser S/W Error Cause : When it senses 1M continuously. Control : Stop Dispenser & Crusher function. Display : Relative ICON BOX is OFF. Termination : Normal 14) Malfunction of Ice Drop Motor Cause : Malfunction of Ice Drop Motor. [Check the Motor by pushing Test S/W.] Termination : Exchange Motor 15) Eu Error Cause : Fully TM position is Error Control : When dropping the Ice, the motor just rotates 90 degree. Termination : Fully sensor is normal. 16) EA Error Cause : When sensing Ice dropping 3 times with level sensor SW Error. Control : Pause Ice Maker. Termination : With level sensor SW is normal, Reset the Power or Push TEST S/W. * When all ERROR CODE is normal, the Refrigerator reset. ! @ # ! @ # ! @ # ! @ ! @ # ! @ # ! @ # CONTENTS REMARKS
29 OPERATION AND FUCTIONS Forced Defrosting INPUT Control Object 1. FREEZER SET. Button 2. REFRIGERATOR SET. button 3. LOCK button Defrosting Mode CONTENTS REMARKS 1. How to start Set LOCK ON first, then push REFRIGERAOTR SET. button 5 times while pushing FREEZER SET. button simultaneously. 2. How to proceed 1) Delete Pre-cool mode. (Others are same as normal defrosting.) 2) Heater is ON regardless of D-sensor temp. at first 30 seconds. ( Check of defrosting current) 6-11. Initial Defrosting INPUT Control Object D-sensor Initial or first power input (power plugin) Defrosting Mode CONTENTS REMARKS If D-sensor temp. ≤ 3.5 , defrosting mode starts from Pre-cool at first power input. Comp. is delayed for 6 min. at the initial defrosting. 6-12. Buzzer or Alarm INPUT Control Object F-PCB buttons Door Switch Initial Power Input BUZZER CONTENTS REMARKS 1. Buzzer sounds if any button of F-PCB is pushed. 2. Buzzer sounds 3 times 3 minutes after initial power input. 3. Buzzer sounds for 1 second in case of A/S forced defrosting, short (pull- down) operation, explanation mode. 4. If door is open, buzzer sounds continually 3 times for 5 seconds. (Door open alarm) LCD Background Light INPUT Control Object F-PCB buttons Door Switch Initial Power Input LCD BACK LIGHT C