Daewoo Fra 280wp Service Manual
Have a look at the manual Daewoo Fra 280wp Service Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 51 Daewoo manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
11 the ice appears in the capillary and becomes more and more, till blocks the hole of capillary completely. In the moment you can find the ice on the evaporator defrosts. The noise of liquid flow disappears. The pressure of absorbing becomes negative. The phenomenon above will appear again and again. The way to check ice blocking: Warm the capillary with a hot towel, after a while the ice in the capillary melt, you can hear a sound of gas flow comes from the capillary abruptly. The pressure of absorbing becomes higher. It is Ice blocking. B, there is offal block the capillary Phenomenon of failure: If the capillary is blocked by something such as offal etc., the sound of liquid flow disappears. The ice on the evaporator defrosts The pressure of absorbing becomes negative. Higher temperature of discharging tube The way to check offal blocking: If you warm capillary with the way of checking ice blocking, there is no change. It must be offal blocking. Solution: First stop unit for several minutes, and then open charging tube, discharge all of Gas. Blow the cycle system with gas of nitrogen. Change a new capillary and filter, and then recharge Gas, finally sealed the system. COMPRESSOR NEVER STOPS Reason Resolvent 1)The setting temperature is not reasonable. Readju st the Thermostat 2)Thermostat is broken. Replace the Thermostat 3)Seal of door is damaged. Replace the gasket 4)Too much food in the refrigerator Please put the food properly. 5)Wind door is broken. Replace wind door. 6)Fan motor is broken. Replace fan motor
13 Compressor Turn on Compressor does not respond Compressor Turn on/off frequently Compressor runs normally replace the starter Compressor runs normally Compressor Turn on/off frequently Replace the starter Check the working current current normal current over follow check the condenser and evaperater GO NEXT Check the door switch (no power)Check the electric outlet, fuse (With power) Check the volt Check both the indoor and outdoor power Adjust the thermostats to fast cooling Lamp dose not turn on Lamp turn on Check the power supply Check the lamp Chech the power Supply Short circle the thermostat Compressor turns on Compressor doesn’t respond Replace the thermostat Replace the stator, over heater compressor turns on Compressor doesn’t respond Replace the starter compressor motor open circle or short circle Compressor blocked up Replace the over heater Compressor break down Power On HfromHFridgehManualzcomHManuals
14 GO NEXT Part of evaporator , condenser cools down,unit runs for long Condenser and evaporator have no respond Slight frost on evaporator, condenser turns hot,compressor runs at high input Normal No pressure in compressor Capillary and filter blocked Refrigerant leak out complete Refrigerant leak out partly partly blocked refrigerant over injected, evaporator overloaded condenser in low efficiency frost over-thick Overloaded, cold air has no convection space Compressor temperature rise up No sound of gas or liquid in evaporator Only sound of gas follow, no sound of liquid follow Liquid follow sound disappear quickly after the unit runs down, pressure goes even fast Liquid follow sound decreases quickly after the unit runs down for a long time, pressure goes even slowly Frost frost on input pipe closely to the compressor Condenser is inefficient because it is located too close to the wall, or covered with thick dust, or the environment temperature is to high Defrost in time Decrease food storage quantity sound of Liquid follow in evaporator outlet/inlet is weak cut off the technique tube, large amount of gas spurt up. Turn on the unit and cover the cut with hand, no suction Replace the compressor Cut off the technique tube, gas-follow sound is weak, and persisting for a very long time. Turn on the unit again with the cut being covered by hand, suction is normal Make out feculence block and frost block, deal with them separately The gas-follow sound disappear quickly after the unit is turned off Cut off the technique tube, little gas follow out Find out the leakage cut and repair Find out the leakage cut and repair Clean it up with N3 and vacuumize it. Replace the exreplacer and vacuumize it, inject N3 Discharge a proper quantity of refrigerant Improve the heat exreplace condition HfromHFridgehManualzcomHManuals
1 NO DISPONIBLE Screw nail ST4.2×13 11 2 1055467 Top cover 1 3 NO DISPONIBLE Screw cover of top cover 2 4 NO DISPONIBLE Flange screw M5x16 7 FRA280WP part lis t NoPart nameQt y CODIGO RECIBIDO FOTO FOTO2
5 NO DISPONIBLE Upper hinge parts 1 6 1375571 Metal shelve of freezer 1 7 NO DISPONIBLE Decoration rod for shelve of freezer 1 8 1050074 BOMBILLA 1 9 NO DISPONIBLE Reflecting batten 1 10 1064752 Anti-explode lamp hold assembly 1 11 1063597 THERMOSTAT / TERMOSTATO 1 12 NO DISPONIBLE Controller cover 1 13 NO DISPONIBLE Block loop 1 14 1051747 Temperature control knob 1 15 NO DISPONIBLE Square screw cover 1
16 NO DISPONIBLE Lamp cover 1 17 NO DISPONIBLE Screw nail 4×12 1 18 1370361 Shelve of cold-storing chamber 3 19 1349718 Crisper box 2 20 NO DISPONIBLE Low hinge parts 1 21 1065091 Low front leg 1 22 NO DISPONIBLE Flange Screw M5x30 2 23 1056893 High front leg 1 24 NO DISPONIBLE Mid-hinge 1 25 NO DISPONIBLE Mid-hinge bottom plate 1 26 1055831 Door switch 1 27 NO DISPONIBLE Screw cover 1 28 NO DISPONIBLE Mid-hinge bottom hole cover 2 29 1051965 Ice tray 1 30 NO DISPONIBLE Top cover support 1 31 NO DISPONIBLE Support paneling 1
32 1055023 GASKET F DOOR AS / BURLETE CONGELADOR1 33 1055804 Small egg tray 1 34 1366275 Upper door 1 35 1055804 Egg tray 1 36 1366282 Lower Door 1 37 1348963 Upper shelve for lower door 2 38 1349883 Lower shelve for lower door 1 39 1051601 GASKET R DOOR AS / BURLETE REFRIGERADOR1 40 1370394 Cover of Crisper box 1 41 NO DISPONIBLE Body of refrigerator 1 42 1051109 Drier filter 1
43 NO DISPONIBLE Backside condensato r 1 44 NO DISPONIBLE Circuit diagram nameplate 1 45 NO DISPONIBLE N case 3 46 NO DISPONIBLE Connecting tube 1 47 NO DISPONIBLE Power supply cord with plug 1 48 NO DISPONIBLE 1 49 NO DISPONIBLE Screw bolt M6×30 4 50 NO DISPONIBLE Screw nut M6 4 51 NO DISPONIBLE Round-pad 6 4 52 NO DISPONIBLE Round-pad 6 4 53 1100216 COMPRESSOR(R600) + RELE+TERMICO+CONDENSADOR DE ARRANQUE+KIT MONTAJE1 54 1414053 Back cover of compressor 1 55 NO DISPONIBLE Process tube 2 56Compressor ground wire 1 57Compressor connecting wire 1 58Ground wire cover1 59 NO DISPONIBLE Screw M5×12 3 60 NO DISPONIBLE Screw nut M5 3 61 NO DISPONIBLE Round-pad M5 5 62 NO DISPONIBLE Round-pad M5 3 63 NO DISPONIBLE Round-pad M5 3 64 NO DISPONIBLE Screw M5×14 2 65 NO DISPONIBLE Screw nut M5 2 66 NO DISPONIBLE Round-pad M6 2 67 NO DISPONIBLE Assembled bolt M6×16 4 68 NO DISPONIBLE Compressor base 1 69 NO DISPONIBLE Screw nail 1 70Junction box 1
SPFRAHANDLE ASA REFRIGERADOR Y CONGELADOR 2 1099078 TORNILLO ASA 4 1118834 COVER SCREW HANDLEFRA280/350W P4